14 resultados para Catheter ablation


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Catheter ablation is an established treatment option for symptomatic atrial fibrillation (AF), with circumferential pulmonary vein isolation being considered the cornerstone of the procedure. However, this is a complex intervention with potential major complications and with common arrhythmia recurrences. There is consensus among experts that all patients should be seen in follow-up regularly after AF ablation. To date there are limited data regarding the best methodology for routine clinical follow-up of this population. This review summarizes a contemporary insight into management of late complications following AF ablation, post-procedural anticoagulation and arrhythmia monitoring strategies, in order to prevent thromboembolic events, detect and treat arrhythmia recurrences, and discuss the use of upstream therapies after AF ablation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Based on a survey sent to Portuguese centers that perform diagnostic and interventional electrophysiology and/or implantable cardioverter-defibrillator (ICD) implantations, the authors analyze the number and type of procedures performed during 2012 and compare these data with previous years. In 2012, a total of 2561 diagnostic electrophysiologic studies were performed, which were followed by ablation in 2017 cases, representing a steady situation compared with the previous year. There was a 12% increase in the number of ablation procedures for atrial fibrillation, making it for the first time the most frequent indication for ablation, overtaking atrioventricular nodal reentrant tachycardia. The total number of first ICD implantations was 1048 (around 100 per million population), of which 375 were cardiac resynchronization devices (BiV ICDs). This represents a slight decrease (3.3%) in the total number of new implants, with an increase of 10% in the number of BiV ICDs compared to the previous year. However, there was a considerable increase in the number of ICD generator replacements, resulting in an overall increase of 3.5% in implantations performed in 2012. Some comments are made regarding developments in this activity and its current status, and on some factors that may influence the dynamics of this area of interventional cardiology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectivo: estudo comparativo simultâneo de medições invasivas utilizando o cateterismo da artéria pulmonar e não invasivas utilizando a ecocardiografia transtorácica (ETT) de 4 parâmetros hemodinâmicos: débito cardíaco (DC), pressão de encravamento da artéria pulmonar (PCP), pressão venosa central (PVC), e pressão sistólica da artéria pulmonar (PSAP). Material e Métodos: estudo prospectivo numa Unidade de Cuidados Intensivos (UCI) médico-cirurgica. Foram estudados 41 doentes em pós-operatório de transplante hepático, nos quais o DC, a PCP, a PVC e a PSAP foram obtidos em simultâneo por 2 observadores independentes, utilizando a ETT e o cateterismo invasivo da artéria pulmonar. Para a quantificação por ETT dos parâmetros foram utilizadas fórmulas descritas na literatura. As medições invasivas e não invasivas foram comparadas através de uma análise de correlação linear e de Bland-Altman. Resultados: Verificou-se uma boa correlação nas medições invasivas e não invasivas do DC (r=0,97) e PVC (r=0,88). As correlações entre as medições invasivas e não invasivas da PCP e da PSAP foram fracas (r=0,41 e r= 0,118 respectivamente). O intervalo de confiança de 95% e bias para o DC foi negligenciável, em especial para valores de DC abaixo dos 6l/minuto. A ETT subestima em regra o DC, mas as duas técnicas mostraram uma correlação significativa entre si. Conclusões: a ETT pode estimar de forma fidedigna o DC em doentes submetidos a transplante hepático. A determinação não invasiva das restantes variáveis hemodinâmicas por ETT pode estar sujeita a uma variabilidade grande relacionada com as características dos doentes. Apesar dos dados terem sido obtidos num grupo específico de doentes, podem ajudar a definir uma aplicação futura da ecocardiografia em Cuidados Intensivos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: We describe our center's initial experience with alcohol septal ablation (ASA) for the treatment of obstructive hypertrophic cardiomyopathy. The procedure, its indications, results and clinical outcomes will be addressed, as will its current position compared to surgical myectomy. OBJECTIVE: To assess the results of ASA in all patients treated in the first four years of activity at our center. METHODS: We retrospectively studied all consecutive and unselected patients treated by ASA between January 2009 and February 2013. RESULTS: In the first four years of experience 40 patients were treated in our center. In three patients (7.5%) the intervention was repeated. Procedural success was 84%. Minor complications occurred in 7.5%. Two patients received a permanent pacemaker for atrioventricular block (6% of those without previous pacemaker). The major complication rate was 5%. There were no in-hospital deaths; during clinical follow-up (22 ± 14 months) cardiovascular mortality was 2.5% and overall mortality was 5%. DISCUSSION AND CONCLUSION: The results presented reflect the initial experience of our center with ASA. The success rate was high and in line with published results, but with room to improve with better patient selection. ASA was shown to be safe, with a low complication rate and no procedure-related mortality. Our experience confirms ASA as a percutaneous alternative to myectomy for the treatment of symptomatic patients with obstructive hypertrophic cardiomyopathy refractory to medical treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Although vascular access is essential for adequate haemodialysis delivery, the systematic use of a patient's venous patrimony may eventually lead to exhaustion of suitable sites for placement of a new vascular access. Case Report: We present two cases of such patients. In the first one we inserted a 55cm catheter through the left external iliac vein, and a 40cm translumbar catheter was placed in the second one. Both interventions were performed percutaneously under radiological guidance. Both patients were anticoagulated after the procedure. Conclusion: Unusual sites for haemodialysis catheter placement may be life saving in selected situations and offer safe and viable alternatives for adequate haemodialysis delivery.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A utilização do catéter de Foley na prática da algaliação está desde há muito definida. Os autores têm, no entanto, utilizado o catéter Foley em diversas situações de recurso, no âmbito da cirurgia cardíaca. A utilização deste método de enorme simplicidade e de muito baixo custo representa um verdadeiro "ovo de Colombo" e deve fazer parte do armentarium cirúrgico alternativo de cada um de nós. Descreve-se o uso do catéter Foley, como alternativa de recurso, nas seguintes situações: 1. Laceração de uma cavidade cardíaca na re-esternotomia com hemorragia catastrófica; 2. Realização de anastomoses proximais em aortas que não devem ou podem ser clampadas (calcificações extensas); 3. Realização de anastomoses de condutos ventrículo-direito artéria pulmonar com o coração a bater.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Slowed atrial conduction may contribute to reentry circuits and vulnerability for atrial fibrillation (AF). The autonomic nervous system (ANS) has modulating effects on electrophysiological properties. However, complex interactions of the ANS with the arrhythmogenic substrate make it difficult to understand the mechanisms underlying induction and maintenance of AF. AIM: To determine the effect of acute ANS modulation in atrial activation times in patients (P) with paroxysmal AF (PAF). METHODS AND RESULTS: 16P (9 men; 59±14years) with PAF, who underwent electrophysiological study before AF ablation, and 15P (7 men; 58±11years) with atrioventricular nodal reentry tachycardia, without documentation or induction of AF (control group). Each group included 7P with arterial hypertension but without underlying structural heart disease. The study was performed while off drugs. Multipolar catheters were placed at the high right atrium (HRA), right atrial appendage (RAA), coronary sinus (CS) and His bundle area (His). At baseline and with HRA pacing (600ms, shortest propagated S2) we measured: i) intra-atrial conduction time (IACT, between RAA and atrial deflection in the distal His), ii) inter-atrial conduction time (interACT, between RAA and distal CS), iii) left atrial activation time (LAAT, between atrial deflection in the distal His and distal CS), iv) bipolar electrogram duration at four atrial sites (RAA, His, proximal and distal CS). In the PAF group, measurements were also determined during handgrip and carotid sinus massage (CSM), and after pharmacological blockade of the ANS (ANSB). AF was induced by HRA programmed stimulation in 56% (self-limited - 6; sustained - 3), 68.8% (self-limited - 6; sustained - 5), and 50% (self-limited - 5; sustained - 3) of the P, in basal, during ANS maneuvers, and after ANSB, respectively (p=NS). IACT, interACT and LAAT significantly lengthened during HRA pacing in both groups (600ms, S2). P with PAF have longer IACT (p<0.05), a higher increase in both IACT, interACT (p<0.01) and electrograms duration (p<0.05) with S2, and more fragmented activity, compared with the control group. Atrial conduction times and electrograms duration were not significantly changed during ANS stimulation. Nevertheless, ANS maneuvers increased heterogeneity of the local electrograms duration. Also, P with sustained AF showed longer interACT and LAAT during CSM. CONCLUSION: Atrial conduction times, electrograms duration and fractionated activity are increased in PAF, suggesting a role for conduction delays in the arrhythmogenic substrate. Acute vagal stimulation is associated with prolonged interACT and LAAT in P with inducible sustained AF and ANS modulation may influence the heterogeneity of atrial electrograms duration.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: to characterize and to assess in terms of severity the surgical and trauma patients admitted to a medical intensive care unit (ICU). DESIGN: retrospective study base on clinical records and the ICU computerized database. SETTING: the medical ICU of a tertiary hospital. RESULTS: of the 2468 patients admitted to the ICU in 1989, 289 (11.7%) were surgical or trauma ones. The more frequent reasons for admission were: the need for mechanical ventilation, metabolic problems, and depression of consciousness. Of these 289 patients, 48.1% required mechanical ventilation, 14.9 hemodialysis; 4.8% had a pulmonary artery catheter inserted. Mean APACHE II, TISS and MOF scores were high (20.09 +/- 9.29, 24.17 +/- 11.45 and 5.4 +/- 3.59); they were determined in 79.2, 88.2 and 43.9% of patients respectively. Both APACHE and TISS scores were correlated with mortality. When compared with medical patients, surgical/trauma ones although younger (52.9 +/- 20.7 years versus 55.9 +/- 20.2, p = 0.00152), had a longer mean stay in the ICU (7.63 +/- 12.7 days v. 3.64 +/- 7.61, p = 0.0001), and a higher mortality (also in the ICU) (28.7 v. 16.7, p = 0.0005. COMMENTS: these are seriously ill patients, who are frequently referred to the ICU in late stages of clinical evolution. We propose they should be closely followed, from the earliest possible stage, by medical-surgical teams, in order to benefit from a multidisciplinary approach.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Upper eyelid tumours, particularly basal cell carcinomas, are relatively frequent. Surgical ablation of these lesions creates defects of variable complexity. Although several options are available for lower eyelid reconstruction, fewer surgical alternatives exist for upper eyelid reconstruction. Large defects of this region are usually reconstructed with two-step procedures. In 1997, Okada et al. described a horizontal V-Y myotarsocutaneous advancement flap for reconstruction of a large upper eyelid defect in a single operative time. However, no further studies were published regarding the use of this particular flap in upper eyelid reconstruction. In addition, this flap is not described in most plastic surgery textbooks. The authors report here their experience of 16 cases of horizontal V-Y myotarsocutaneous advancement flaps used to reconstruct full-thickness defects of the upper eyelid after tumour excision. The tumour histological types were as follows: 12 basal cell carcinomas, 2 cases of squamous cell carcinomas, 1 case of sebaceous cell carcinoma and 1 of malignant melanoma. This technique allowed closure of defects of up to 60% of the eyelid width. None of the flaps suffered necrosis. The mean operative time was 30 min. No additional procedures were necessary as good functional and cosmetic results were achieved in all cases. No recurrences were noted. In this series, the horizontal V-Y myotarsocutaneous advancement flap proved to be a technically simple, reliable and expeditious option for reconstruction of full-thickness upper eyelid defects (as wide as 60% of the eyelid width) in a single operative procedure. In the future this technique may become the preferential option for such defects.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The role of cerebral angiography in the diagnosis of cerebrovascular disease is currently being questioned due to both the increasing availability of carotid sonography and the recent introduction of Magnetic Resonance Angiography (MRA). After a technical foreword about the different modalities available today in Cerebral Angiography, we discuss its present indications (Conventional or Digital subtraction by intra-arterial route), in patients with extra and intra cranial atherosclerotic cerebro vascular disease, subarachnoid hemorrhage and arterial aneurysms, in vascular malformations, particularly arterio-venous malformations (AVM's), in occlusive non-atherosclerotic non hypertensive arteriopathies and in occlusive venous pathology. Although it is possible that the future will show us the progressive replacement of the invasive technologies by MRA, at the present stage of Magnetic Resonance development there is still an important role, if not crucial, for catheter angiography in the diagnosis of most of the diseases producing stroke syndromes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Acquired factor X deficiency is an extremely rare situation. It has shown to be associated with systemic amyloidosis, respiratory mycoplasma infection, factor X inhibitors, antiphospholipid antibodies, vitamin K defi ciency/liver disease as well as the use of certain medications (meropenem, valproic acid). The pathogenesis and transient nature of this deficit remain poorly understood. The authors describe the case of a teenager hospitalised for extensive burns that developed active bleeding after removal of central venous catheter. He was diagnosed with transient factor X deficiency. Normalisation of coagulation status and factor X levels occurred spontaneously 10 days after the bleeding episode.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: The use of cardiac output monitoring may improve patient outcomes after major surgery. However, little is known about the use of this technology across nations. METHODS: This is a secondary analysis of a previously published observational study. Patients aged 16 years and over undergoing major non-cardiac surgery in a 7-day period in April 2011 were included into this analysis. The objective is to describe prevalence and type of cardiac output monitoring used in major surgery in Europe. RESULTS: Included in the analysis were 12,170 patients from the surgical services of 426 hospitals in 28 European nations. One thousand four hundred and sixteen patients (11.6 %) were exposed to cardiac output monitoring, and 2343 patients (19.3 %) received a central venous catheter. Patients with higher American Society of Anesthesiologists (ASA) scores were more frequently exposed to cardiac output monitoring (ASA I and II, 643 patients [8.6 %]; ASA III-V, 768 patients [16.2 %]; p < 0.01) and central venous catheter (ASA I and II, 874 patients [11.8 %]; ASA III-V, 1463 patients [30.9 %]; p < 0.01). In elective surgery, 990 patients (10.8 %) were exposed to cardiac output monitoring, in urgent surgery 252 patients (11.7 %) and in emergency surgery 173 patients (19.8 %). A central venous catheter was used in 1514 patients (16.6 %) undergoing elective, in 480 patients (22.2 %) undergoing urgent and in 349 patients (39.9 %) undergoing emergency surgery. Nine hundred sixty patients (7.9 %) were monitored using arterial waveform analysis, 238 patients (2.0 %) using oesophageal Doppler ultrasound, 55 patients (0.5 %) using a pulmonary artery catheter and 44 patients (2.0 %) using other technologies. Across nations, cardiac output monitoring use varied from 0.0 % (0/249 patients) to 27.5 % (19/69 patients), whilst central venous catheter use varied from 5.6 % (7/125 patients) to 43.2 % (16/37 patients). CONCLUSIONS: One in ten patients undergoing major surgery is exposed to cardiac output monitoring whilst one in five receives a central venous catheter. The use of both technologies varies widely across Europe.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Canine dirofilariosis is a life-threatening parasitic disease that is increasingly reported worldwide. Once diagnosed the main treatment goals are to improve the animal's clinical condition and to eliminate all life stages of the parasite with minimal posttreatment side effects. This can be achieved through mechanical, surgical, or chemotherapeutical approaches. Currently, manual extraction is the preferred method to remove adult heartworms due to its diminished invasiveness, reduced damage to the vascular endothelium, and shortened anaesthesia duration. However, it remains an expensive technique that can be highly traumatic. To address this issue, a nontraumatic homemade catheter-guided snare was developed for heartworm removal by adapting and folding a 0.014-inch coronary wire (BMW, Abbott Vascular). Transvenous heartworm extraction was performed on a dog severely infected with adult heartworms by inserting the modified snare into a 6-F Judkins right coronary guiding catheter BMW (Cordis) and advancing it into the right ventricle under fluoroscopic guidance. Fifteen adult specimens of Dirofilaria immitis were successfully extracted from the pulmonary artery and right ventricle without complications. To assure the death of both larvae and adults, postoperative treatment was successfully managed using ivermectin, doxycycline, and melarsomine, with no recurrence after surgery.