4 resultados para Capture-recapture Data


Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: The Genous™ stent (GS) is designed to accelerate endothelization, which is potentially useful in the pro-thrombotic environment of ST-elevation acute myocardial infarction (STEMI). We aimed to evaluate the safety and effectiveness of the GS in the first year following primary percutaneous coronary intervention (PCI) and to compare our results with the few previously published studies. METHODS AND MATERIALS: All patients admitted to a single center due to STEMI that underwent primary PCI using exclusively GS, between May 2006 and January 2012, were enrolled. The primary study endpoints were major adverse cardiac events (MACEs), defined as the composite of cardiac death, acute myocardial infarction and target vessel revascularization, at one and 12months. RESULTS: In the cohort of 109 patients (73.4% male, 59 ±12years), 24.8% were diabetic. PCI was performed in 116 lesions with angiographic success in 99.1%, using 148 GS with median diameter of 3.00mm (2.50-4.00) and median length of 15mm (9-33). Cumulative MACEs were 2.8% at one month and 6.4% at 12months. Three stent thromboses (2.8%), all subacute, and one stent restenosis (0.9%) occurred. These accounted for the four target vessel revascularizations (3.7%). At 12months, 33.9% of patients were not on dual antiplatelet therapy. CONCLUSIONS: GS was safe and effective in the first year following primary PCI in STEMI, with an apparently safer profile comparing with the previously published data. SUMMARY: We report the safety and effectiveness of the Genous™ stent (GS) in the first year following primary percutaneous coronary intervention in ST-elevation acute myocardial infarction. A comprehensive review of the few studies that have been published on this subject was included and some suggest a less safe profile of the GS. Our results and the critical review included may add information and reinforce the safety and effectiveness of the GS in ST-elevation in acute myocardial infarction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A pilot study aimed to introduce intraoperative monitoring of liver surgery using transoesophageal echocardiography (TEE) is described. A set of TEE measurements was established as a protocol, consisting of left atrial (LA) dimension at the aortic valve plane; mitral velocity flow integral, calculation of stroke volume and cardiac output (CO); mitral annular plane systolic excursion; finally, right atrial area. A total of 165 measurements (on 21 patients) were performed, 31 occurring during hypotension. The conclusions reached were during acute blood loss LA dimension changed earlier than CVP, and, in one patient, a dynamic left ventricular (LV) obstruction was observed; in 3 patients a transient LV systolic dysfunction was documented. The comparison between 39 CO paired measurements obtained by TEE and PiCCO2 revealed a statistically significant correlation (P < 0.001, r = 0.83). In this pilot study TEE successfully answered the questions raised by the anesthesiologists. Larger cohort studies are needed to address this issue.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS: To evaluate the long-term clinical outcomes following percutaneous coronary intervention (PCI) with the Genous stent in an unselected population. METHODS: All patients admitted to a single center who underwent PCI using the GS exclusively, between May 2006 and May 2012, were enrolled, and a clinical follow-up of up to 60 months was carried out. The primary endpoint of major adverse cardiac event (MACE) rate was defined as the composite of cardiac death, acute myocardial infarction (AMI), and target lesion revascularization (TLR). RESULTS: Of the 450 patients included (75.1% male; 65.5 ± 11.7 years), 28.4% were diabetic and acute coronary syndrome was the reason for PCI in 76.4%. Angioplasty was performed in 524 lesions using 597 Genous stents, with angiographic success in 97.1%. At a median of 36 months of follow-up (range, 1-75 months), MACE, AMI, TLR, stent restenosis (SR), and stent thrombosis (ST) rates were 15.6%, 8.4%, 4.4%, 3.8%, and 2.2%, respectively. Between 12 and 24 months, the TLR, SR, and ST rates practically stabilized, up to 60 months. Bifurcation lesions were independently associated with MACE, TLR, and SR. CONCLUSION: This is the first study reporting clinical results with the Genous stent up to 60 months. The Genous stent was safe and effective in the long-term, in an unselected population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction. Pulmonary arterial hypertension (PAH) is a rare disease that must be managed in specialized centers; therefore, the availability of epidemiological national data is critical. Methods. We conducted a prospective, observational, and multicenter registry with a joint collaboration from five centers from Portugal and included adult incident patients with PAH or chronic thromboembolic pulmonary hypertension (CTEPH). Results. Of the 79 patients enrolled in this study, 46 (58.2%) were classified as PAH and 33 patients (41.8%) as CTEPH. PAH patients had a mean age of 43.4 ± 16.4 years. Idiopathic PAH was the most common etiology (37%). At presentation, PAH patients had elevated right atrial pressure (RAP) (7.7 ± 5.9mmHg) and mean pulmonary vascular resistance (11.4 ± 6.5 Wood units), with a low cardiac index (2.7 ± 1.1 L⋅min−1 m−2); no patient was under selective pulmonary vasodilators; however, at follow-up, most patients were on single (50%), double (28%), or triple (9%) combination vasodilator therapy. One-year survival was 93.5%, similar to CTEPH patients (93.9%), that were older (60.0 ± 12.5 years) and had higher RAP (11.0 ± 5.2mmHg,