3 resultados para Baseline length


Relevância:

30.00% 30.00%

Publicador:

Resumo:

To assess the degree of discomfort caused by length measurement in neonates, performed with one or both lower limbs extended, on the first and second day after birth, with either one or both lower limbs extended. METHODS: Healthy full-term neonates were systematically sampled during the months of February and March 2004. Crown-heel length was measured, using a 1-mm precision neonatometer, at approximately 8 h and 32 h after birth, with one and both lower limbs extended. The Neonatal Facial Coding System was used to assess discomfort during measurements. Data were analysed by parametric and non-parametric tests as appropriate. RESULTS: Whatever the measurement technique, discomfort scores are significantly higher during the length measurement than at baseline. Whenever length measurements are performed, discomfort scores are significantly higher when extending both lower limbs rather than one lower limb (p < 0.006). The measured length is greater with one lower limb extended; however, the difference decreases over time, being 0.19 cm (95% CI 0.1-0.3; p < 0.001) at approximately 32 h of age. No significant differences in length were found between measurements at approximately 8 or 32 h, regardless of the technique used. The best correlation between length measurements with one or both lower limbs extended was observed at approximately 32 h after birth (r = 0.98). CONCLUSION: Measuring crown-heel length is a distressful procedure for the neonate. Measurements with one lower limb extended result in less discomfort than when both lower limbs are extended, without decreasing the accuracy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE:Endograft mural thrombus has been associated with stent graft or limb thrombosis after endovascular aneurysm repair (EVAR). This study aimed to identify clinical and morphologic determinants of endograft mural thrombus accumulation and its influence on thromboembolic events after EVAR. METHODS: A prospectively maintained database of patients treated by EVAR at a tertiary institution from 2000 to 2012 was analyzed. Patients treated for degenerative infrarenal abdominal aortic aneurysms and with available imaging for thrombus analysis were considered. All measurements were performed on three-dimensional center-lumen line computed tomography angiography (CTA) reconstructions. Patients with thrombus accumulation within the endograft's main body with a thickness >2 mm and an extension >25% of the main body's circumference were included in the study group and compared with a control group that included all remaining patients. Clinical and morphologic variables were assessed for association with significant thrombus accumulation within the endograft's main body by multivariate regression analysis. Estimates for freedom from thromboembolic events were obtained by Kaplan-Meier plots. RESULTS: Sixty-eight patients (16.4%) presented with endograft mural thrombus. Median follow-up time was 3.54 years (interquartile range, 1.99-5.47 years). In-graft mural thrombus was identified on 30-day CTA in 22 patients (32.4% of the study group), on 6-month CTA in 8 patients (11.8%), and on 1-year CTA in 17 patients (25%). Intraprosthetic thrombus progressively accumulated during the study period in 40 patients of the study group (55.8%). Overall, 17 patients (4.1%) presented with endograft or limb occlusions, 3 (4.4%) in the thrombus group and 14 (4.1%) in the control group (P = .89). Thirty-one patients (7.5%) received an aortouni-iliac (AUI) endograft. Two endograft occlusions were identified among AUI devices (6.5%; overall, 0.5%). None of these patients showed thrombotic deposits in the main body, nor were any outflow abnormalities identified on the immediately preceding CTA. Estimated freedom from thromboembolic events at 5 years was 95% in both groups (P = .97). Endograft thrombus accumulation was associated with >25% proximal aneurysm neck thrombus coverage at baseline (odds ratio [OR], 1.9; 95% confidence interval [CI], 1.1-3.3), neck length ≤ 15 mm (OR, 2.4; 95% CI, 1.3-4.2), proximal neck diameter ≥ 30 mm (OR, 2.4; 95% CI, 1.3-4.6), AUI (OR, 2.2; 95% CI, 1.8-5.5), or polyester-covered stent grafts (OR, 4.0; 95% CI, 2.2-7.3) and with main component "barrel-like" configuration (OR, 6.9; 95% CI, 1.7-28.3). CONCLUSIONS: Mural thrombus formation within the main body of the endograft is related to different endograft configurations, main body geometry, and device fabric but appears to have no association with the occurrence of thromboembolic events over time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The baseline susceptibility of primary HIV-2 to maraviroc (MVC) and other entry inhibitors is currently unknown. METHODS: The susceptibility of 19 HIV-2 isolates obtained from asymptomatic and AIDS patients and seven HIV-1 clinical isolates to the fusion inhibitors enfuvirtide (ENF) and T-1249, and to the coreceptor antagonists AMD3100, TAK-779 and MVC, was measured using a TZM-bl cell-based assay. The 50% inhibitory concentration (IC(50)), 90% inhibitory concentration (IC(90)) and dose-response curve slopes were determined for each drug. RESULTS: ENF and T-1249 were significantly less active on HIV-2 than on HIV-1 (211- and 2-fold, respectively). AMD3100 and TAK-779 inhibited HIV-2 and HIV-1 CXCR4 tropic (X4) and CCR5 tropic (R5) variants with similar IC(50) and IC(90) values. MVC, however, inhibited the replication of R5 HIV-2 variants with significantly higher IC(90) values (42.7 versus 9.7 nM; P<0.0001) and lower slope values (0.7 versus 1.3; P<0.0001) than HIV-1. HIV-2 R5 variants derived from AIDS patients were significantly less sensitive to MVC than variants from asymptomatic patients, this being inversely correlated with the absolute number of CD4(+) T-cells. CONCLUSIONS: T-1249 is a potent inhibitor of HIV-2 replication indicating that new fusion inhibitors might be useful to treat HIV-2 infection. Coreceptor antagonists TAK-779 and AMD3100 are also potent inhibitors of HIV-2 replication. The reduced sensitivity of R5 variants to MVC, especially in severely immunodeficient patients, indicates that the treatment of HIV-2-infected patients with MVC might require higher dosages than those used in HIV-1 patients, and should be adjusted to the disease stage.