5 resultados para BALANCE CLOSURE PROBLEM


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Leg ulcers constitute a highly prevalent pathology in society, and are particularly common in the Angiology and Vascular Surgery outpatient clinic. The prevalence of these patients in this Department result from the fact that 70% of them display superficial and/or deep venous insufficiency of the lower limbs. To address this problem and optimize the therapeutic approaches available to the Chronic Leg Ulcer (CLU) patients, the Department of Angiology and Vascular Surgery has created, in March 2005, an appointment specific to CLU patients. An evaluation protocol was developed, including ulcer characterization, standardization of the conservative treatment, followed by surgical intervention, whenever required. The results obtained were evaluated 18 months after the onset of this protocol. Analysis of the results revealed that the majority of the patients responded positively to the new therapeutic approach, with closure of the ulcer in 43% of the patients and a significant improvement detected for an additional 30%. Furthermore, it was observed that a detailed evaluation of these patients should be regarded as a whole, followed by a standardized and targeted approach, resulting in a particularly successful approach on the treatment of this pathology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introdução: Muitos dos instrumentos disponíveis para a avaliação do equilíbrio, risco de queda e medo de cair medem apenas actividades simples no domicílio e apresentam tendência para um “efeito de tecto” em idosos residentes na comunidade. A “Activities-specific Balance Confidence (ABC) Scale” foi concebida para avaliar o equilíbrio de forma abrangente, num conjunto de actividades de vida diária associadas a um largo espectro de dificuldade. Objectivos: Traduzir para português e adaptar culturalmente para Portugal a “Activities-specific Balance Confidence (ABS) Scale” e avaliar a sua fiabilidade. População e Métodos: Tradução e adaptação cultural do instrumento e subsequente aplicação a uma população idosa portuguesa, para determinação da sua fiabilidade inter-observador, fiabilidade intra-observador e consistência interna. Resultados: Os resultados foram muito homogéneos na grande maioria das comparações realizadas, quer intra-observador, quer inter-observador. A avaliação da consistência interna revelou valores muito elevados. Estes níveis de fiabilidade mantiveram-se mesmo removendo qualquer uma das 16 questões que compõem o questionário, mantendo-se praticamente constantes os valores registados com o questionário completo. Conclusões: A versão portuguesa da escala ABC demonstrou boa fiabilidade intra-observador, fiabilidade inter-observador e consistência interna na avaliação da auto-percepção do equilíbrio para diversas actividades de vida diária numa população idosa portuguesa. Outros trabalhos serão necessários para avaliar a utilidade desta escala na avaliação do risco de queda e do efeito de intervenções terapêuticas nesta população.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Primary angle closure occurs as a result of crowded anterior segment anatomy, causing appositional contact between the peripheral iris and trabecular meshwork, thereby obstructing aqueous outflow. Several studies highlight the role of the crystalline lens in its pathogenesis. The objective of this work is to compare the long-term efficacy of phacoemulsification versus laser peripheral iridotomy (LPI) in the management of chronic primary angle closure (CPAC). Prospective case-control study with 30 eyes of 30 patients randomly divided in two groups: 15 eyes in the LPI group and 15 eyes in the IOL group. Patients in the LPI group underwent LPI using argon and Nd:YAG laser. Patients in the IOL group underwent phacoemulsification with posterior chamber intraocular lens (IOL) implantation. Examinations before and after the procedure included gonioscopy, Goldmann applanation tonometry, and anterior chamber evaluation using the Pentacam rotating Scheimpflug camera. The mean follow-up time was 31.13 ± 4.97 months. There was a statistically significant reduction in the intraocular pressure (IOP) and number of anti-glaucoma medications (p < 0.01) only in the IOL group. Anterior chamber depth, angle, and volume were all higher in the IOL group (p < 0.01) at the end of the follow-up period. Phacoemulsification with posterior chamber IOL implantation results in a higher anterior chamber depth, angle, and volume, when compared to LPI. Consequently, phacoemulsification has greater efficacy in lowering IOP and preventing its long-term increase in patients with CPAC and cataract.

Relevância:

20.00% 20.00%

Publicador: