2 resultados para ARM COORDINATION


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To compare measurements of the upper arm cross-sectional areas (total arm area,arm muscle area, and arm fat area of healthy neonates) as calculated using anthropometry with the values obtained by ultrasonography. Materials and methods: This study was performed on 60 consecutively born healthy neonates: gestational age (mean6SD) 39.661.2 weeks, birth weight 3287.16307.7 g, 27 males (45%) and 33 females (55%). Mid-arm circumference and tricipital skinfold thickness measurements were taken on the left upper mid-arm according to the conventional anthropometric method to calculate total arm area, arm muscle area and arm fat area. The ultrasound evaluation was performed at the same arm location using a Toshiba sonolayer SSA-250AÒ, which allows the calculation of the total arm area, arm muscle area and arm fat area by the number of pixels enclosed in the plotted areas. Statistical analysis: whenever appropriate, parametric and non-parametric tests were used in order to compare measurements of paired samples and of groups of samples. Results: No significant differences between males and females were found in any evaluated measurements, estimated either by anthropometry or by ultrasound. Also the median of total arm area did not differ significantly with either method (P50.337). Although there is evidence of concordance of the total arm area measurements (r50.68, 95% CI: 0.55–0.77) the two methods of measurement differed for arm muscle area and arm fat area. The estimated median of measurements by ultrasound for arm muscle area were significantly lower than those estimated by the anthropometric method, which differed by as much as 111% (P,0.001). The estimated median ultrasound measurement of the arm fat was higher than the anthropometric arm fat area by as much as 31% (P,0.001). Conclusion: Compared with ultrasound measurements using skinfold measurements and mid-arm circumference without further correction may lead to overestimation of the cross-sectional area of muscle and underestimation of the cross-sectional fat area. The correlation between the two methods could be interpreted as an indication for further search of correction factors in the equations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Upper arm anthropometry has been used in the nutritional assessment of small infants, but it has not yet been validated as a predictor of regional body composition in this population. Objective: Validation of measured and derived upper arm anthropometry as a predictor of arm fat and fat-free compartments in preterm infants. Methods: Upper arm anthropometry, including the upper arm cross-sectional areas, was compared individually or in combination with other anthropometric measurements, with the cross-sectional arm areas measured by magnetic resonance imaging, in a cohort of consecutive preterm appropriate-for-gestationalage neonates, just before discharge. Results: Thirty infants born with (mean 8 SD) a gestational age of 30.7 8 1.9 weeks and birth weight of 1,380 8 325 g, were assessed at 35.4 8 1.1 weeks of corrected gestational age, weighing 1,785 8 93 g. None of the anthropometric measurements are reliable predictors (r 2 ! 0.56) of the measurements obtained by magnetic resonance imaging, individually or in combination with other anthropometric measurements. Conclusion: Both measured anthropometry and derived upper arm anthropometry are inaccurate predictors of regional body composition in preterm appropriate-for-gestational-age infants.