The autonomic nervous system (ANS) is known to be an important modulator in the pathogenesis of paroxysmal atrial fibrillation (PAF). Changes in ANS control of heart rate variability (HRV) occur during orthostatism to maintain cardiovascular homeostasis. Wavelet transform has emerged as a useful tool that provides time-frequency decomposition of the signal under investigation, enabling intermittent components of transient phenomena to be analyzed. AIM: To study HRV during head-up tilt (HUT) with wavelet transform analysis in PAF patients and healthy individuals (normals). METHODS: Twenty-one patients with PAF (8 men; age 58 +/- 14 yrs) were examined and compared with 21 normals (7 men, age 48 +/- 12 yrs). After a supine resting period, all subjects underwent passive HUT (60 degrees) while in sinus rhythm. Continuous monitoring of ECG and blood pressure was carried out (Task Force Monitor, CNSystems). Acute changes in RR-intervals were assessed by wavelet analysis and low-frequency power (LF: 0.04-0.15 Hz), high-frequency power (HF: 0.15-0.60 Hz) and LF/HF (sympathovagal) were calculated for 1) the last 2 min of the supine period; 2) the 15 sec of tilting movement (TM); and 3) the 1st (TT1) and 2nd (TT2) min of HUT. Data are expressed as means +/- SEM. RESULTS: Baseline and HUT RR-intervals were similar for the two groups. Supine basal blood pressure was also similar for the two groups, with a sustained increase in PAF patients, and a decrease followed by an increase and then recovery in normals. Basal LF, HF and LF/ HF values in PAF patients were 632 +/- 162 ms2, 534 +/- 231 ms2 and 1.95 +/- 0.39 respectively, and 1058 +/- 223 ms2, 789 +/- 244 ms2 and 2.4 +/- 0.36 respectively in normals (p = NS). During TM, LF, HF and LF/HF values for PAF patients were 747 +/- 277 ms2, 387 +/- 94 ms2 and 2.9 +/- 0.6 respectively, and 1316 +/- 315 ms2, 698 +/- 148 ms2 and 2.8 +/- 0.6 respectively in normals (p < 0.05 for LF and HF). During TF1, LF, HF and LF/ HF values for PAF patients were 1243 +/- 432 ms2, 302 +/- 88 ms2 and 7.7 +/- 2.4 respectively, and 1992 +/- 398 ms2, 333 +/- 76 ms2 and 7.8 +/- 0.98 respectively for normals (p < 0.05 for LF). During TF2, LF, HF and LF/HF values for PAF patients were 871 +/- 256 ms2, 242 +/- 51 ms2 and 4.7 +/- 0.9 respectively, and 1263 +/- 335 ms2, 317 +/- 108 ms2 and 8.6 +/- 0.68 respectively for normals (p < 0.05 for LF/HF). The dynamic profile of HRV showed that LF and HF values in PAF patients did not change significantly during TM or TT2, and LF/HF did not change during TM but increased in TT1 and TT2. CONCLUSION: Patients with PAF present alterations in HRV during orthostatism, with decreased LF and HF power during TM, without significant variations during the first minutes of HUT. These findings suggest that wavelet transform analysis may provide new insights when assessing autonomic heart regulation and highlight the presence of ANS disturbances in PAF.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

BACKGROUND: Wireless capsule endoscopy has been introduced as an innovative, non-invasive diagnostic technique for evaluation of the gastrointestinal tract, reaching places where conventional endoscopy is unable to. However, the output of this technique is an 8 hours video, whose analysis by the expert physician is very time consuming. Thus, a computer assisted diagnosis tool to help the physicians to evaluate CE exams faster and more accurately is an important technical challenge and an excellent economical opportunity. METHOD: The set of features proposed in this paper to code textural information is based on statistical modeling of second order textural measures extracted from co-occurrence matrices. To cope with both joint and marginal non-Gaussianity of second order textural measures, higher order moments are used. These statistical moments are taken from the two-dimensional color-scale feature space, where two different scales are considered. Second and higher order moments of textural measures are computed from the co-occurrence matrices computed from images synthesized by the inverse wavelet transform of the wavelet transform containing only the selected scales for the three color channels. The dimensionality of the data is reduced by using Principal Component Analysis. RESULTS: The proposed textural features are then used as the input of a classifier based on artificial neural networks. Classification performances of 93.1% specificity and 93.9% sensitivity are achieved on real data. These promising results open the path towards a deeper study regarding the applicability of this algorithm in computer aided diagnosis systems to assist physicians in their clinical practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The clinical efficacy of continuous infusion of piperacillin/tazobactam in critically ill patients with microbiologically documented infections is currently unknown. We conducted a retrospective multicenter cohort study in 7 Portuguese intensive care units (ICU). We included 569 critically ill adult patients with a documented infection and treated with piperacillin/tazobactam admitted to one of the participating ICU between 2006 and 2010. We successfully matched 173 pairs of patients according to whether they received continuous or conventional intermittent dosing of piperacillin/tazobactam, using a propensity score to adjust for confounding variables. The majority of patients received 16g/day of piperacillin plus 2g/day of tazobactam. The 28-day mortality rate was 28.3% in both groups (p = 1.0). The ICU and in-hospital mortality were also similar either in those receiving continuous infusion or intermittent dosing (23.7% vs. 20.2%, p = 0.512 and 41.6% vs. 40.5%, p = 0.913, respectively). In the subgroup of patients with a Simplified Acute Physiology Score (SAPS) II>42, the 28-day mortality rate was lower in the continuous infusion group (31.4% vs. 35.2%) although not reaching significance (p = 0.66). We concluded that the clinical efficacy of piperacillin/tazobactam in this heterogeneous group of critically ill patients infected with susceptible bacteria was independent of its mode of administration, either continuous infusion or intermittent dosing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: In the haemodynamically unstable patient the method of treatment of acute renal failure is still largely controversial. The purpose of our study was to compare slow extended dialysis with continuous haemodiafiltration in the critical patient with indication for renal replacement therapy and haemodynamic instability. Patients and Methods: This is a cohort study comparing in 63 ventilated critical patients a 12 month period when only continuous haemodiafiltration was used (n=25) with an equal period of slow extended dialysis (n=38). Our primary objective was to evaluate the impact of the dialytic procedure on cardiovascular stability in those patients. As secondary aims we considered system coagulation/thrombosis and predictors of mortality. In the two groups we analysed the first session performed, the second session performed and the average of all the sessions performed in each patient. Results: In these patients, mortality in the intensive care unit was high (68% in the continuous haemodiafiltration group and 63% in the slow extended dialysis group). We did not find any association between the dialytic technique used and death; only the APACHE score was a predictor of death. Slow extended dialysis was a predictor of haemodynamic stability, a negative predictor of sessions that had to be interrupted for haemodynamic instability, and a predictor of achieving the volume removal initially sought. Slow extended dialysis was also associated with less coagulation of the system. Conclusions: Our data suggested that slow extended dialysis use was not inferior to continuous haemodiafiltration use in terms of cardiovascular tolerability.