6 resultados para Split-operator Methods
em Reposit
Resumo:
Background: A new method for determining serum specific IgE (IMMULITE“ 2000 3gAllergy) has recently become available. Objective: To evaluate the clinical performance of IMMULITE 2000 in the diagnosis of cow’s milk allergy compared with that of UniCAP“. Additionally, we verified the behavior of both methods at two diagnostic decision points proposed by other authors. Methods: The study population consisted of 31 children with cow’s milk allergy (group A) and a control group of 19 atopic children without food allergy(group B). A blood sample from each child was tested using both methods and the results were compared. Results: In group A, the values for cow’s milk IgE ranged from 0.35 kU/L (the lowest common detection limit) to above 100 kU/L. In group B, the values were less than 1.1 kU/L for IMMULITE 2000 and less than 1.6 kU/L for UniCAP. An agreement of 90 % in IgE classes was obtained. Both methods demonstrated exactly the same diagnostic performance(sensitivity: 100 %; specificity: 78.9 %; negative predictive value: 100%; positive predictive value: 84.6%;efficiency: 90.2 %). The evaluation of the two methods at the two different decision points proposed in the literature showed a better positive predictive value with UniCAP, but we obtained equivalent performance with IMMULITE 2000 by choosing higher cutoff values. Conclusions: We conclude that IMMULITE 2000 is as effective as UniCAP in the diagnosis of cow’s milk allergy. Both methods can be used to obtain site-specific decision points that are population, age and disease dependent.
Resumo:
Objective: To compare measurements of the upper arm cross-sectional areas (total arm area,arm muscle area, and arm fat area of healthy neonates) as calculated using anthropometry with the values obtained by ultrasonography. Materials and methods: This study was performed on 60 consecutively born healthy neonates: gestational age (mean6SD) 39.661.2 weeks, birth weight 3287.16307.7 g, 27 males (45%) and 33 females (55%). Mid-arm circumference and tricipital skinfold thickness measurements were taken on the left upper mid-arm according to the conventional anthropometric method to calculate total arm area, arm muscle area and arm fat area. The ultrasound evaluation was performed at the same arm location using a Toshiba sonolayer SSA-250AÒ, which allows the calculation of the total arm area, arm muscle area and arm fat area by the number of pixels enclosed in the plotted areas. Statistical analysis: whenever appropriate, parametric and non-parametric tests were used in order to compare measurements of paired samples and of groups of samples. Results: No significant differences between males and females were found in any evaluated measurements, estimated either by anthropometry or by ultrasound. Also the median of total arm area did not differ significantly with either method (P50.337). Although there is evidence of concordance of the total arm area measurements (r50.68, 95% CI: 0.55–0.77) the two methods of measurement differed for arm muscle area and arm fat area. The estimated median of measurements by ultrasound for arm muscle area were significantly lower than those estimated by the anthropometric method, which differed by as much as 111% (P,0.001). The estimated median ultrasound measurement of the arm fat was higher than the anthropometric arm fat area by as much as 31% (P,0.001). Conclusion: Compared with ultrasound measurements using skinfold measurements and mid-arm circumference without further correction may lead to overestimation of the cross-sectional area of muscle and underestimation of the cross-sectional fat area. The correlation between the two methods could be interpreted as an indication for further search of correction factors in the equations.
Resumo:
BACKGROUND: Atherosclerotic carotid disease represents approximately 20% of the causes of ischemic stroke. Effective treatment options, such as endovascular or surgical revascularization procedures, are available. Doppler Ultrasound (DUS) is a non-invasive, inexpensive, routine exam used to evaluate the presence of internal carotid artery (ICA) stenosis. We retrospectively analysed the prevalence of severe atherosclerotic carotid disease in a population of patients with acute ischemic stroke/transitory ischemic attacks (TIAs), and the role of DUS in the detection of ICA stenosis and treatment decisions in these patients. METHODS: A total of 318 patients with ischemic stroke or TIAs was admitted to our stroke unit, and 260 patients were studied by DUS. ICA stenosis was evaluated by DUS according to peak systolic velocity. All DUS exams were performed by the same operator. ICA stenosis was further assessed in 43 patients by digital subtraction angiography (DSA) using NASCET criteria. RESULTS: Of the total 318 patients, 260 (82%) had DUS evaluation. Of the total 520 ICAs studied by DUS, degrees of ICA stenosis were: 0-29% n= 438 (84%); 30-49% n= 8 (2%); 50-69% n= 27 (5%); 70-89% n= 15 (3%); 90-99% n= 20 (4%); oclusão n= 14 (2%). Of the total 260 patients studied, 43 (16.5%) underwent DSA. Sensibility and specificity of DUS in the diagnosis of carotid stenosis over 70% were, respectively, 91% e 84%. Of the total 31 patients with significant carotid stenosis (70-99%), 23 (74%) underwent subsequent carotid revascularization procedures. DISCUSSION: DUS is an important screening test in our stroke unit, justifying its use as a routine exam for all patients with ischemic stroke/TIAs. Moreover, our results show the relevance of severe carotid disease in a population with acute ischemic stroke/TIAs (16.5%), with a total of 9% of patients being submitted to carotid revascularization procedures.
Resumo:
BACKGROUND: Prospective testing for posttransplant circulating anti-HLA antibodies seems to be a critical noninvasive tool, but confirmatory data are lacking. MATERIALS AND METHODS: Over the last 3 years, peritubular capillary (PTC) C4d deposition was prospectively sought by an immunofluorescence technique applied to frozen tissue in biopsies obtained for allograft dysfunction. Screening for circulating anti-HLA class I/II alloantibodies (AlloAb) by the flow cytometric test was performed simultaneously. RESULTS: We evaluated 132 sets of biopsies and simultaneous serum samples. PTC C4d deposition was demonstrated in 15.9% (21/132) of biopsies. Circulating anti-HLA I/II AlloAb were detected in 25% (33/132) of serum samples. Employing receiver-operator characteristic (ROC) curves for all C4d-positive biopsies, screening for AlloAb showed a global specificity of 82% and sensitivity of 61.9%. When this analysis was restricted to biopsies obtained in the first month posttransplantation, the sensitivity increased to 81.8%, but the specificity decreased to 76.9%. After the first month posttransplantation, we observed sensitivity of 40.0% and a specificity of 86.4%. In the first month posttransplantation, all patients with a diagnosis of acute antibody-mediated rejection displayed circulating anti-HLA class I/II, but not always at the same time as the C4d-positive biopsy. CONCLUSIONS: In the first month posttransplantation, prospective monitoring of anti-HLA antibodies may be useful. The high sensitivity allows the identification of patients at risk, affording an earlier diagnosis of antibody-mediated rejection. After the first month, the test can be used to evaluate allograft dysfunction episodes, since positivity is highly suggestive of an antibody-mediated process.
Resumo:
Overview and Aims: The investigation of recurrent miscarriage includes the study of uterine morphology. 3D ultrasound allows the evaluation of the morphology (cavity and outer contour), reducing the need for invasive tests such as hystero - salpingography (HSG), hysteroscopy and laparoscopy. We evaluated the diagnostic agreement between HSG and 3D ultrasound in the study of the uterine cavity morphology. Study Design: Prospective study. Population: A total of 34 women referred to our institution with a history of recurrent miscarriage. Methods: To compare the results of 3D ultrasound and HSG, all women underwent both exams. 3D scans were performed by the same operator and HSG were evaluated by the same clinician. The concordance study was performed using the Kappa coefficient. Results: With 3D ultrasound and HSG, uterine anomalies were diagnosed in 52.9% (18/34) and 47% (16/34) of the cases and congenital malformations were the most frequent findings. The agreement between the two techniques was excellent(K = 0.825). The three cases of diagnostic disagreement were analyzed. Conclusion: A high level of diagnostic agreement was observed between HSG and 3D ultrasound. The 3D ultrasound, a low cost and well tolerated technique, when performed by an experienced operator, is the first line exam to study the uterine morphology in women with recurrent miscarriage.
Resumo:
Clinically childhood occipital lobe epilepsy (OLE) manifests itself with distinct syndromes. The traditional EEG recordings have not been able to overcome the difficulty in correlating the ictal clinical symptoms to the onset in particular areas of the occipital lobes. To understand these syndromes it is important to map with more precision the epileptogenic cortical regions in OLE. Experimentally, we studied three idiopathic childhood OLE patients with EEG source analysis and with the simultaneous acquisition of EEG and fMRI, to map the BOLD effect associated with EEG spikes. The spatial overlap between the EEG and BOLD results was not very good, but the fMRI suggested localizations more consistent with the ictal clinical manifestations of each type of epileptic syndrome. Since our first results show that by associating the BOLD effect with interictal spikes the epileptogenic areas are mapped to localizations different from those calculated from EEG sources and that by using different EEG/fMRI processing methods our results differ to some extent, it is very important to compare the different methods of processing the localization of activation and develop a good methodology for obtaining co-registration maps of high resolution EEG with BOLD localizations.