3 resultados para Interactive Device

em Reposit


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aims of the present study were to test the association between insecure attachment and basal cortisol and catecholamines levels in a sample of obese children. The role of familial vulnerability and gender was also investigated. Methods: Cortisol and catecholamines levels of 8- to 13-year olds obese children were measured. Self-report questionnaires were used to assess attachment pattern and current anxiety and depression, and parent-report questionnaires were used to assess attachment, current anxiety and depression and familial vulnerability. Linear regression analyses were performed for individuals that scored low versus high on parental internalizing problems, and for boys and girls, separately. Results: In the group with high parental internalizing problems, insecure attachment was significantly associated with reduced basal levels of cortisol, in boys (p=0.007, b= -0.861, R2= 73.0%). In the group with low parental internalizing problems, the association between insecure attachment and cortisol was not significant in either boys or girls, and it was negative in boys (p=0.075, b= -0.606, R2= 36.7%) and positive in girls (p=0.677, b= 0.176, R2= 3.1%) . Conclusions: Apparently, physiological risk factors for psicopathology in obesity are more evident in individuals with a high familial vulnerability. In addition, patterns of physiological risk for psicopathology in obesity are different in boys and girls. Therefore, it is important to take into account familial vulnerability and gender when investigating physiological risk factors for psycopathology in obesity. Insecure attachment in childhood may be a risk factor for obesity. Interventions to increase children's attachment security should examine the effects on children's weight.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective:We aimed to identify if there was any difference in Levonorgestrel-releasing intrauterine system (LNG-IUS) efficacy or weight gain when used in heavy menstrual bleeding (HMB) treatment, between obese and non-obese women. Population and methods: This was a case-controlled retrospective study undertaken between 2002-2007. 194 women with HMB were treated with LNG-IUS and stratified into two groups accordingly with body mass index (BMI): Obese Group – BMI ≥ 30 (n=53) and Non-obese Group – BMI < 30 (n=141). Age, weight, days of spotting and days of menses were analyzed at 1, 3 and 6 months after insertion and then annually until 2 years. Analytic parameters of anemia (hemoglobin, serum ferritin, mean corpuscular volume) were reviewed at pre-insertion, at 6 months and then annually until 2 years. Results: During the 2-year follow-up there was a similar improvement in two groups regarding duration of menses, spotting and in analytic parameters of anemia. A statistically significant improvement was observed in obese group after 2 years of treatment regarding analytic parameters of anemia and menstrual characteristics, without weight gain. Conclusion: In obese women, the LNG-IUS is an effective treatment for heavy menstrual bleeding, without being associated to weight gain.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Mitral regurgitation (MR) is the most common valvular disease and has recently become the target of a number of percutaneous approaches. The MitraClip is virtually the only device for which there is considerable experience, with more than 20,000 procedures performed worldwide. OBJECTIVE: To describe our initial experience of the percutaneous treatment of MR with the MitraClip device. METHODS: We describe the first six MitraClip cases performed in this institution (mean age 58.5 ± 13.1 years), with functional MR grade 4+ and New York Heart Association (NYHA) heart failure class III or IV (n=3), with a mean follow-up of 290 ± 145 days. RESULTS: Procedural success (MR ≤ 2+) was 100%. Total procedure time was 115.8 ± 23.7 min, with no in-hospital adverse events and discharge between the fourth and eighth day, and consistent improvement in the six-minute walk test (329.8 ± 98.42 vs. 385.33 ± 106.95 m) and in NYHA class (three patients improved by two NYHA classes). During follow-up there were two deaths, in two of the four patients who had been initially considered for heart transplantation. CONCLUSION: In patients with functional MR the MitraClip procedure is safe, with both a high implantation and immediate in-hospital success rate. A longer follow-up suggests that the clinical benefit decreases or disappears completely in patients with more advanced heart disease, namely those denied transplantation or on the heart transplant waiting list.