3 resultados para Data Coding.

em Reposit


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A pilot study aimed to introduce intraoperative monitoring of liver surgery using transoesophageal echocardiography (TEE) is described. A set of TEE measurements was established as a protocol, consisting of left atrial (LA) dimension at the aortic valve plane; mitral velocity flow integral, calculation of stroke volume and cardiac output (CO); mitral annular plane systolic excursion; finally, right atrial area. A total of 165 measurements (on 21 patients) were performed, 31 occurring during hypotension. The conclusions reached were during acute blood loss LA dimension changed earlier than CVP, and, in one patient, a dynamic left ventricular (LV) obstruction was observed; in 3 patients a transient LV systolic dysfunction was documented. The comparison between 39 CO paired measurements obtained by TEE and PiCCO2 revealed a statistically significant correlation (P < 0.001, r = 0.83). In this pilot study TEE successfully answered the questions raised by the anesthesiologists. Larger cohort studies are needed to address this issue.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction. Pulmonary arterial hypertension (PAH) is a rare disease that must be managed in specialized centers; therefore, the availability of epidemiological national data is critical. Methods. We conducted a prospective, observational, and multicenter registry with a joint collaboration from five centers from Portugal and included adult incident patients with PAH or chronic thromboembolic pulmonary hypertension (CTEPH). Results. Of the 79 patients enrolled in this study, 46 (58.2%) were classified as PAH and 33 patients (41.8%) as CTEPH. PAH patients had a mean age of 43.4 ± 16.4 years. Idiopathic PAH was the most common etiology (37%). At presentation, PAH patients had elevated right atrial pressure (RAP) (7.7 ± 5.9mmHg) and mean pulmonary vascular resistance (11.4 ± 6.5 Wood units), with a low cardiac index (2.7 ± 1.1 L⋅min−1 m−2); no patient was under selective pulmonary vasodilators; however, at follow-up, most patients were on single (50%), double (28%), or triple (9%) combination vasodilator therapy. One-year survival was 93.5%, similar to CTEPH patients (93.9%), that were older (60.0 ± 12.5 years) and had higher RAP (11.0 ± 5.2mmHg,

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To assess the degree of discomfort caused by length measurement in neonates, performed with one or both lower limbs extended, on the first and second day after birth, with either one or both lower limbs extended. METHODS: Healthy full-term neonates were systematically sampled during the months of February and March 2004. Crown-heel length was measured, using a 1-mm precision neonatometer, at approximately 8 h and 32 h after birth, with one and both lower limbs extended. The Neonatal Facial Coding System was used to assess discomfort during measurements. Data were analysed by parametric and non-parametric tests as appropriate. RESULTS: Whatever the measurement technique, discomfort scores are significantly higher during the length measurement than at baseline. Whenever length measurements are performed, discomfort scores are significantly higher when extending both lower limbs rather than one lower limb (p < 0.006). The measured length is greater with one lower limb extended; however, the difference decreases over time, being 0.19 cm (95% CI 0.1-0.3; p < 0.001) at approximately 32 h of age. No significant differences in length were found between measurements at approximately 8 or 32 h, regardless of the technique used. The best correlation between length measurements with one or both lower limbs extended was observed at approximately 32 h after birth (r = 0.98). CONCLUSION: Measuring crown-heel length is a distressful procedure for the neonate. Measurements with one lower limb extended result in less discomfort than when both lower limbs are extended, without decreasing the accuracy.