2 resultados para Outpatient

em Repositório do Centro Hospitalar de Lisboa Central, EPE - Centro Hospitalar de Lisboa Central, EPE, Portugal


Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION: Sleepiness is a cardinal symptom in obstructive sleep apnoea (OSA) but most patients have unspecific symptoms. Arterial stiffness, evaluated by pulse wave velocity (PWV), is related to atherosclerosis and cardiovascular (CV) risk. Arterial stiffness was reported to be higher in patients with OSA, improving after treatment with continuous positive airway pressure (CPAP). This study aims to assess whether the same effect occurs in patients with OSA and without sleepiness. METHODS AND ANALYSIS: This observational study assesses the CV effect of CPAP therapy on a cohort of patients with moderate-to-severe OSA; the effect on the subcohorts of sleepy and non-sleepy patients will be compared. A systematic and consecutive sample of patients advised CPAP therapy will be recruited from a single outpatient sleep clinic (Centro Hospitalar de Lisboa Central-CHLC, Portugal). Eligible patients are male, younger than 65 years, with confirmed moderate-to-severe OSA and apnoea-hypopnea index (AHI) above 15/hour. Other sleep disorders, diabetes or any CV disease other than hypertension are exclusion criteria. Clinical evaluation at baseline includes Epworth Sleepiness Scale (ESS), and sleepiness is defined as ESS above 10. OSA will be confirmed by polygraphic study (cardiorespiratory, level 3). Participants are advised to undertake an assessment of carotid-femoral PWV (cf-PWV) and 24 hours evaluation of ambulatory blood pressure monitoring (ABPM), at baseline and after 4 months of CPAP therapy. Compliance and effectiveness of CPAP will be assessed. The main outcome is the variation of cf-PWV over time.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIMS: Device-based remote monitoring (RM) has been linked to improved clinical outcomes at short to medium-term follow-up. Whether this benefit extends to long-term follow-up is unknown. We sought to assess the effect of device-based RM on long-term clinical outcomes in recipients of implantable cardioverter-defibrillators (ICD). METHODS: We performed a retrospective cohort study of consecutive patients who underwent ICD implantation for primary prevention. RM was initiated with patient consent according to availability of RM hardware at implantation. Patients with concomitant cardiac resynchronization therapy were excluded. Data on hospitalizations, mortality and cause of death were systematically assessed using a nationwide healthcare platform. A Cox proportional hazards model was employed to estimate the effect of RM on mortality and a composite endpoint of cardiovascular mortality and hospital admission due to heart failure (HF). RESULTS: 312 patients were included with a median follow-up of 37.7months (range 1 to 146). 121 patients (38.2%) were under RM since the first outpatient visit post-ICD and 191 were in conventional follow-up. No differences were found regarding age, left ventricular ejection fraction, heart failure etiology or NYHA class at implantation. Patients under RM had higher long-term survival (hazard ratio [HR] 0.50, CI 0.27-0.93, p=0.029) and lower incidence of the composite outcome (HR 0.47, CI 0.27-0.82, p=0.008). After multivariate survival analysis, overall survival was independently associated with younger age, higher LVEF, NYHA class lower than 3 and RM. CONCLUSION: RM was independently associated with increased long-term survival and a lower incidence of a composite endpoint of hospitalization for HF or cardiovascular mortality.