17 resultados para zero voltage switching


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Digital Microfluidics (DMF) is a second generation technique, derived from the conventional microfluidics that instead of using continuous liquid fluxes, it uses only individual droplets driven by external electric signals. In this thesis a new DMF control/sensing system for visualization, droplet control (movement, dispensing, merging and splitting) and real time impedance measurement have been developed. The software for the proposed system was implemented in MATLAB with a graphical user interface. An Arduino was used as control board and dedicated circuits for voltage switching and contacts were designed and implemented in printed circuit boards. A high resolution camera was integrated for visualization. In our new approach, the DMF chips are driven by a dual-tone signal where the sum of two independent ac signals (one for droplet operations and the other for impedance sensing) is applied to the electrodes, and afterwards independently evaluated by a lock-in amplifier. With this new approach we were able to choose the appropriated amplitudes and frequencies for the different proposes (actuation and sensing). The measurements made were used to evaluate the real time droplet impedance enabling the knowledge of its position and velocity. This new approach opens new possibilities for impedance sensing and feedback control in DMF devices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

IEEE International Symposium on Circuits and Systems, MAY 25-28, 2003, Bangkok, Thailand. (ISI Web of Science)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

IEEE Electron Device Letters, VOL. 29, NO. 9,

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para a obtenção do grau de Mestre em Engenharia Electrotécnica e de Computadores

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertation presented to obtain the PhD degree in Electrical and Computer Engineering - Electronics

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada como requisito parcial para obtenção do grau de Mestre em Estatística e Gestão de Informação.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia Civil – Perfil Construção

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Work Project, presented as part of the requirements for the Award of a Masters Degree in Finance from the NOVA – School of Business and Economics

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia Eletrotécnica e de Computadores, pela Universidade Nova de Ciências e Tecnologia

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia Electrotécnica e Computadores

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Doutor em Engenharia Electrotécnica e de Computadores

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Work Project, presented as part of the requirements for the Award of a Masters Degree in Finance from the NOVA – School of Business and Economics

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Relatório de estágio curricular na editora Zero a Oito, para obtenção do grau de mestre em Edição de Texto, pela Faculdade de Ciências Sociais e Humanas da Universidade Nova de Lisboa. Este trabalho visa relatar os conhecimentos práticos e teóricos consolidados no pré e pós estágio na Zero a Oito. O meu relatório irá focar-se na multiplicidade de tarefas que um editor tem dentro de uma editora orientada para crianças, principalmente os projetos em que estive envolvida na editora.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this thesis a CMOS low-power and low-voltage RF receiver front-end is presented. The main objective is to design this RF receiver so that it can be powered by a piezoelectric energy harvesting power source, included in a Wireless Sensor Node application. For this type of applications the major requirements are: the low-power and low-voltage operation, the reduced area and cost and the simplicity of the architecture. The system key blocks are the LNA and the mixer, which are studied and optimized with greater detail, achieving a good linearity, a wideband operation and a reduced introduction of noise. A wideband balun LNA with noise and distortion cancelling is designed to work at a 0.6 V supply voltage, in conjunction with a double-balanced passive mixer and subsequent TIA block. The passive mixer operates in current mode, allowing a minimal introduction of voltage noise and a good linearity. The receiver analog front-end has a total voltage conversion gain of 31.5 dB, a 0.1 - 4.3 GHz bandwidth, an IIP3 value of -1.35 dBm, and a noise figure lower than 9 dB. The total power consumption is 1.9 mW and the die area is 305x134.5 m2, using a standard 130 nm CMOS technology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Neste estudo aborda-se o novo conceito dos edifícios com necessidades quase nulas de energia (Nearly Zero Energy Buildings, NZEB) no parque edificado Europeu, nomeadamente os edifícios de habitação que serão construídos a partir de 2020. Estes edifícios terão que respeitar os requisitos mínimos de eficiência energética de modo a reduzir a dependência dos combustíveis fósseis que tem vindo a aumentar significativamente ao longo dos últimos anos. Ao longo deste trabalho foi modelado e dimensionado um edifício de habitação unifamiliar situado na zona de Lisboa e recorreu-se a técnicas e estratégias que aumentam a eficiência energética do mesmo. Este dimensionamento foi feito recorrendo ao software DesignBuilder, tendo sido em seguida efetuada uma análise energética, com recurso ao software EnergyPlus. Posteriormente à análise estar feita, realizou-se um estudo utilizando o software SolTerm para se integrar sistemas de produção de energia renovável no edifício, de modo a tentar suprir as necessidades energéticas do edifício no que se refere a aquecimento ambiente, águas quentes sanitárias (AQS) e necessidades elétricas. Para suprir as necessidades de arrefecimento e aquecimento que o sistema solar térmico não tem capacidade de suprir foi introduzida uma bomba de calor, reduzindo assim o consumo elétrico tornando o edifício mais sustentável. Já para produção de energia elétrica foi inserido um sistema solar fotovoltaico. Foi avaliada também nesta fase a relação custo-benefício da aplicação de cada um destes sistemas, de modo a escolher aquele que maximiza o suprimento das necessidades e que ao mesmo tempo é economicamente viável. Por último foi realizada uma análise crítica aos resultados obtidos e é feito o enquadramento com o que é pretendido num edifício NZEB.