8 resultados para vesicle curvature


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This present study aimed to investigate the fatigue life of unused (new) endodontic instruments made of NiTi with control memory by Coltene™ and subjected to the multi curvature of a mandibular first molar root canal. Additionally, the instrument‟s structural behaviour was analysed through non-linear finite element analysis (FEA). The fatigue life of twelve Hyflex™ CM files was assessed while were forced to adopt a stance with multiple radius of curvature, similar to the ones usually found in a mandibular first molar root canal; nine of them were subjected to Pecking motion, a relative movement of axial type. To achieve this, it was designed an experimental setup with the aim of timing the instruments until fracture while worked inside a stainless steel mandibular first molar model with relative axial motion to simulate the pecking motion. Additionally, the model‟s root canal multi-curvature was confirmed by radiography. The non-linear finite element analysis was conducted using the computer aided design software package SolidWorks™ Simulation, in order to define the imposed displacement required by the FEA, it was necessary to model an endodontic instrument with simplified geometry using SolidWorks™ and subsequently analyse the geometry of the root canal CAD model. The experimental results shown that the instruments subjected to pecking motion displayed higher fatigue life values and higher lengths of fractured tips than those with only rotational relative movement. The finite element non-linear analyses shown, for identical conditions, maximum values for the first principal stress lower than the yield strength of the material and those were located in similar positions to the instrument‟s fracture location determined by the experimental testing results.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para a obtenção do grau de Mestre em Engenharia Biomédica. A presente dissertação foi desenvolvida no Erasmus Medical Center em Roterdão, Holanda

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A thesis submitted in fulfilment of the requirements for the degree of Masters in Molecular Genetics and Biomedicine

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertation submitted in partial fulfillment of the requirements for the Degree of Master of Science in Geospatial Technologies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A Work Project, presented as part of the requirements for the Award of a Masters Degree in Finance from the NOVA – School of Business and Economics

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A thesis submitted in fulfillment of the requirements for the degree of the Masters in Molecular Genetics and Biomedicine

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The organizer is a ciliated signalling transient organ, responsible for the patterning of embryo tissues during embryonic development. In higher vertebrates, such as mouse and chick, this organizer (the node and the Hensen’s node, respectively) performs dorsalventral and anteriorposterior axis definition, as well as left-right patterning of the internal organs. In lower vertebrates, such as frog and zebrafish, there is a separate specialized organ for left-right purposes called the Gastrocoel Roof Plate (GRP) and Kupffer’s Vesicle (KV), respectively. It is known that mouse and chick organizer cells give rise to structures like floor plate, notochord, hypochord and somites. Frog GRP originates all these but floor plate. In zebrafish, at 13-14 somite stage (ss) the KV finished its left-right patterning but what happens to this organizer’ cells is still poorly studied. This research attempts to understand the fate and behaviour of the KV cells. We followed the fate of KV cells by live imaging and by tight time-courses with fixed larvae. We assessed in detail their proliferative and death profile, as well as cilia length progression from 9-10 ss until 29-30 ss. We conclude that the KV cells mostly follow the evolutionarily conserved fates described for other organizers. These cells mainly incorporate the notochord and hypochord; few cells incorporate the floor plate and the somites. As a novelty, it is also hypothesized that the hypural cell fate may be among the KV cell fates.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Application of Experimental Design techniques has proven to be essential in various research fields, due to its statistical capability of processing the effect of interactions among independent variables, known as factors, in a system’s response. Advantages of this methodology can be summarized in more resource and time efficient experimentations while providing more accurate results. This research emphasizes the quantification of 4 antioxidants extraction, at two different concentration, prepared according to an experimental procedure and measured by a Photodiode Array Detector. Experimental planning was made following a Central Composite Design, which is a type of DoE that allows to consider the quadratic component in Response Surfaces, a component that includes pure curvature studies on the model produced. This work was executed with the intention of analyzing responses, peak areas obtained from chromatograms plotted by the Detector’s system, and comprehending if the factors considered – acquired from an extensive literary review – produced the expected effect in response. Completion of this work will allow to take conclusions regarding what factors should be considered for the optimization studies of antioxidants extraction in a Oca (Oxalis tuberosa) matrix.