11 resultados para strain gauge measurements


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Since the invention of photography humans have been using images to capture, store and analyse the act that they are interested in. With the developments in this field, assisted by better computers, it is possible to use image processing technology as an accurate method of analysis and measurement. Image processing's principal qualities are flexibility, adaptability and the ability to easily and quickly process a large amount of information. Successful examples of applications can be seen in several areas of human life, such as biomedical, industry, surveillance, military and mapping. This is so true that there are several Nobel prizes related to imaging. The accurate measurement of deformations, displacements, strain fields and surface defects are challenging in many material tests in Civil Engineering because traditionally these measurements require complex and expensive equipment, plus time consuming calibration. Image processing can be an inexpensive and effective tool for load displacement measurements. Using an adequate image acquisition system and taking advantage of the computation power of modern computers it is possible to accurately measure very small displacements with high precision. On the market there are already several commercial software packages. However they are commercialized at high cost. In this work block-matching algorithms will be used in order to compare the results from image processing with the data obtained with physical transducers during laboratory load tests. In order to test the proposed solutions several load tests were carried out in partnership with researchers from the Civil Engineering Department at Universidade Nova de Lisboa (UNL).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau em Mestre em Engenharia Física

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Quimica Nova, Vol. 32, Nº2

Relevância:

20.00% 20.00%

Publicador:

Resumo:

1st European IAHR Congress, 6-4 May, Edinburgh, Scotland

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia Biomédica

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RESUMO: A operação de Nissen, por laparoscopia, é considerada a cirurgia antirefluxo mais adequada por ser a que melhor replica a fisiologia normal da válvula gastresofágica na maioria dos doentes com sintomas típicos de doença do refluxo gastresofágico (DRGE). São critérios técnicos o encerramento seguro dos pilares do diafragma e a criação de fundoplicatura completa (360 graus), curta (inferior a dois centímetros), lassa e sem tensão – desiderando para o qual a laqueação proximal dos vasos curtos gástricos é crucial. Realizei a operação de Nissen, por laparoscopia, em sessenta mulheres e quarenta homens com DRGE, sem mortalidade operatória, no Serviço de Cirurgia 6 do Hospital dos Capuchos, CHLC, EPE. Os cem doentes apresentavam média etária de 46 anos e queixas, com tempo de evolução entre 1 e 43 anos, de pirose (90%), regurgitação (80%), azia (73%), epigastralgias (54%). A endoscopia alta revelou esofagite de grau Savary-Miller 0-I (62%), II (23%), III (8%), IV (7%); hérnia de deslizamento (71%), hérnia paraesofágica (8%), sem hérnia (21%); a pHmetria de 24h diagnosticou padrão misto (38%), levantado (20%), deitado (20%), inconclusiva (22%) e a manometria diagnosticou EEI hipotónico (35%), peristálise esofágica normal (88%), hipomotilidade ligeira (5%) e foi omissa (7%). Hérnia hiatal, esofagite grave, ineficácia do controlo sintomático com inibidor da bomba de protões e desejo de descontinuidade terapêutica constituíram as indicações para tratamento cirúrgico. Por celioscopia, efetuei laqueação dos vasos curtos gástricos (70%), cruroplastia e fundoplicatura total (seda 2/0), curta (dimensão média 1,5-2 cm), lassa, sem tensão e sem calibração intraoperatória do esófago. A fundoplicatura de Nissen laparoscópica mostrou-se segura e eficaz no tratamento da DRGE. A sua idoneidade foi ainda comprovada pela normalização da pHmetria de 24 horas e da manometria pós-operatórias, com significado estatístico, num grupo de catorze voluntários assintomáticos. Em catamnese com recuo médio 30,7 meses 94% dos indivíduos persistem assintomáticos. Interrogando-me acerca das repercussões desta operação sobre a microcirculação do fundo gástrico coloquei, como premissa, a possibilidade de na operação de Nissen a laqueação dos vasos curtos poder induzir modificação no diâmetro arteriolar da parede do fundo gástrico. Para pesquisar a influência da laqueação dos vasos curtos gástricos e da fundoplicatura total sobre o calibre arteriolar da parede do estômago no cárdia, no fundo e na região dos vasos curtos gástricos, idealizei um Projeto de investigação experimental em cobaias. O Projeto foi desenvolvido no Centro de Investigação do Departamento de Anatomia da FCM-UNL. Para a sua realização obtive autorização da Comissão Científica e Pedagógica da FCM-UNL, requeri a acreditação como investigador à Direção Geral de Veterinária e, por recorrer à utilização de animais, submeti-o à Comissão de Ética da FCM-UNL, que o aprovou por unanimidade. Para limitar o número de animais utilizados ao mínimo necessário, calculei, por método estatístico, a quantidade de cobaias necessárias. Subdividindo-as num grupo de ensaio (GE), onde realizei a operação de Nissen, e num grupo de controlo (GC), onde apenas procedi a tração gástrica, defini e apliquei protocolos de anestesia, de cirurgia e de eutanásia, segundo os princípios dos 3R – Replacement, Reduction, Refinement da técnica de experimentação humana de Russell e Burch (1959) – uma estrutura ética amplamente aceite para a realização de experimentação científica humanizada com animais. A utilização das técnicas de estudo angiomorfológico permitiu-me analisar e descrever a anatomia normal, a vascularização arterial macroscópica, a microangioarquitetura, por microscopia eletrónica de varrimento de moldes de corrosão vascular, e a histologia da parede do estômago da cobaia. Procedi, também, à definição dos critérios morfológicos que considerei suscetíveis de validação deste modelo animal para o estudo proposto. Por razões académicas, foi necessário abreviar o Projeto encurtando, em cerca de dois anos, o prazo disponível para conclusão do estudo. Apreciando-o com o Gabinete de Análise Epidemiológica e Estatística do Centro de Investigação do CHLC, EPE, optou-se, perante a escassez de elementos após já terem sido recrutados 46 animais, por uma amostra, suplementar, de dimensão de conveniência de oito cobaias (quatro em cada grupo), condicionada pelo limite temporal universitário e pelo respeito pela dignidade dos animais. Neste subgrupo procedi, por microscopia eletrónica de varrimento, à medição dos calibres arteriolares nos moldes vasculares do cárdia, do fundo e da zona dos vasos curtos gástricos tanto no GC como no GE efetuando 469 medições no primeiro e 461 no último. Os dados foram enviados ao Centro de Investigação do CHLC, EPE que procedeu à sua análise estatística (ANOVA). A referida análise revelou que as arteríolas do plexo mucoso e as do plexo submucoso do cárdia, do fundo e da região dos vasos curtos gástricos, mostraram aumento de calibre no GE. O aumento foi, estatisticamente, significativo por ser superior a 50% do calibre do GC. Nos vasos curtos, a diferença foi mais pequena, mas persistiu sendo, estatisticamente, significativa. Os vasos retos dilataram na base, na sua emergência do plexo seroso, apenas no fundo gástrico. Na cobaia a operação de Nissen – fundoplicatura total com laqueação dos vasos curtos gástricos –, provocou vasodilatação arteriolar do fundo gástrico. Considero que essa vasodilatação constituiu acomodação à modificação introduzida e infiro que o mesmo possa acontecer no ser humano. Admito, assim, que também ocorra vasodilatação no ser humano, na sequência da laqueação dos vasos curtos gástricos, pela analogia microvascular entre as duas espécies e que essa vasodilatação corresponda, igualmente, a um mecanismo de adaptação arteriolar visando, por exemplo, suprir a perda incorrida pela laqueação. A associação experimental entre laqueação dos vasos curtos gástricos e realização de fundoplicatura total, que exerce aumento inerente de pressão sobre a JEG, não só não provocou défice da microcirculação do esófago distal ou do estômago proximal como desencadeou um mecanismo de vasodilatação fúndica que reforça o conceito de segurança da operação de Nissen para tratamento da DRGE. -------------- ABSTRACT: The laparoscopic Nissen operation is considered to be the most appropriate antirefluxsurgery because it suitably replicates the standard physiology of the gastroesophageal valve in most patients with typical symptoms of gastroesophageal reflux disease (GERD). The technical criteria includes the safe shutdown of the diafragmatic crura(cruroplasty) and the creation of a complete fundoplication (360 degrees), short (lesser than two inches), floppy and without tension – a goal for which the proximal ligation of the gastric short vessels is crucial. The laparoscopic Nissen operation was performed in sixty women and forty men with GERD, without any operative mortality, at the Surgical Department of the Hospital dos Capuchos, CHLC, EPE. The one hundred patients, averaged 46 years old, complained of heartburn (90%), regurgitation (80%) and upper abdominal pain (54 %). The endoscopy process revealed Savary-Miller esophagitis of grade 0-I (62%), II (23%), III (8%), IV (7%), sliding hernia (71%), paraesophageal hernia (8%) or no herniation (21%). The pHmetry/24h diagnosed mixed pattern (38%), raised (20%), lying (20%) or inconclusive (22%). The manometry diagnosed hypotensive LES (35%), normal esophageal peristalsis (88%), mild hypomotility (5%) and was absent (7%). Hiatal hernia, severe esophagitis, ineffective symptomatic control with proton pump inhibitor and request for treatment discontinuation were the signs for surgical action. A laparoscopic ligation of short gastric vessels (70%), cruroplasty and fundoplication (silk 2/0), short (average size 1.5–2 cm) and floppy, without tension and without intraoperative calibration of the esophagus were thus performed. The laparoscopic Nissen fundoplication behaved safe and effective in treating GERD. In a group of 14 asymptomatic volunteers its reputation was confirmed with statistical significance by normalization of postoperative pHmetry/24h and manometry. 94% of the individuals remained asymptomatic up to 30.7 months (average) in the follow-up. Interrogating myself about the impact of this operation on the microcirculation of the gastric fundus I put premised on the possibility of the ligation of the short gastric vessels in the Nissen procedure can induce changes in the arteriolar diameter in the Wall of the gastric fundus. To explore the influence of ligation of the short gastric vessels and the fundoplication at the arteriolar caliber of the cardia, the fundus and the region of the short vessels of the gastric wall, I designed a project of experimental research in guinea pigs with two interdependent components: one veterinary and another technical where I applied angiomorphological studies. The project was developed at the Research Centre of the Department of Anatomy FCMUNL. For its accomplishment I got permission from the Scientific and Pedagogical Committee of the FCM-UNL, I requested for accreditation as a researcher at the General Directorate of Veterinary and, by resorting to the use of animals I submitted it to the Ethics Committee of the FCM-UNL, which approved it unanimously. The guinea pigs were divided into two experimental groups: an experimental group (EG), in which the Nissen procedure was performed and a control group (CG) in which only a gastric traction was done. Protocols of anesthesia, surgery and euthanasia were applied according to the 3Rs – Replacement, Reduction, Refinement of the technique of human experimentation of Burch and Russell (1959) – a widely accepted ethical framework for conducting scientific experiments using animals humanely. Using histological and angiomorphological techniques, I performed the analysis and the description of the normal, macro and microvascular, anatomy of the guinea pig stomach and I defined the morphological criteria that I considered susceptible for validation of this animal model for the proposed study. By means of scanning electron microscopy I measured the arteriolar calibers of the vascular casts of the cardia, of the fundus and of the short gastric vessels in both CG and EG, making 469 measurements in the former and 461 in the latter. The data were sent to the Research Center of the CHLC which conducted the statistical analysis (ANOVA). The data were sent to the Centre for Research of the CHLC, EPE which proceeded to statistical analysis (ANOVA). This analysis revealed that the arterioles plexus of the mucosal and submucosal plexus of the cardia, fundus and region of the short gastric vessels, showed increased caliber in EG. The increase was statistically significant for being greater than 50% CG gauge. In the short gastric vessels, the difference was smaller, but persisted and statistically significant. Straight vessels were dilated at the base, on its emergence of the plexus serous only in the fundus. In the guinea pig, the Nissen procedure - complete fundoplication with ligation of the short gastric vessels - caused arteriolar vasodilation on the gastric fundus. I believe that this vasodilation constituted some accommodation to the modification introduced and infer that the same might happen in humans. I admit therefore that vasodilation also occurs in humans following the ligation of the short gastric vessels by microvascular analogy between the two species and that this vasodilation corresponds also to na adaptation mechanism arteriolar, for example, to compensate the loss incurred by ligation. The association of experimental ligation of the short gastric vessels with conducting complete fundoplication, which exerts increased pressure on the EGJ, not only did not cause a microcirculation deficit of the distal esophagus or proximal stomach as triggered a mechanism of fundic vasodilation which reinforces the security concept of the Nissen procedure for treatment of GERD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Shape memory alloys are characterized by the ability of recovering their initial shape after being deformed and by superelasticity. Since the discovery of these alloys, a new field of interest emerged not only for the scientific community but also to many industries. However, these alloys present poor machinability which constitute a constrain in the design of complex components for new applications. Thus, the demand for joining techniques able to join these alloys without compromising their properties became of great importance to enlarge the complexity of existing applications. Literature shows that these alloys are joined mainly using laser welding. In the present study, similar NiTi butt joints, were produced using TIG welding. The welds were performed in 1.5 mm thick plates across the rolling direction. A special fixture and gas assist device was designed and manufactured. Also a robot arm was adapted to accommodate the welding torch to assure the repeatability of the welding parameters. Welds were successfully achieved without macroscopic defects, such as pores and distortions. Very superficial oxidation was seen on the top surface due to insufficient shielding gas flow on the weld face. The welded joints were mechanically tested and structurally characterized. Testing methods were used to evaluate macro and microstructure, as well as the phase transformation temperatures, the mechanical single and cyclic behaviour and the shape recovery ability. Differential Scanning Calorimetry (DSC), Scanning Electron Microscopy (SEM), Energy Dispersive Spectroscopy (EDS), microhardness measurements were techniques also used to evaluate the welded joints. A depletion in Ni in the fusion zone was seen, as well as a shift in Ms temperature. For strain values of 4% the accumulated irrecoverable strain was of about 30% and increased with the strain imposed during cycling. Nevertheless, a complete recovery of initial shape was observed when testing the shape memory effect on a dedicated device that introduces a deformation of 6.7%. That is, the welding procedure does not remove the ability of the specimens to recover their initial shape.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The “CMS Safety Closing Sensors System” (SCSS, or CSS for brevity) is a remote monitoring system design to control safety clearance and tight mechanical movements of parts of the CMS detector, especially during CMS assembly phases. We present the different systems that makes SCSS: its sensor technologies, the readout system, the data acquisition and control software. We also report on calibration and installation details, which determine the resolution and limits of the system. We present as well our experience from the operation of the system and the analysis of the data collected since 2008. Special emphasis is given to study positioning reproducibility during detector assembly and understanding how the magnetic fields influence the detector structure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In cataract surgery, the eye’s natural lens is removed because it has gone opaque and doesn’t allow clear vision any longer. To maintain the eye’s optical power, a new artificial lens must be inserted. Called Intraocular Lens (IOL), it needs to be modelled in order to have the correct refractive power to substitute the natural lens. Calculating the refractive power of this substitution lens requires precise anterior eye chamber measurements. An interferometry equipment, the AC Master from Zeiss Meditec, AG, was in use for half a year to perform these measurements. A Low Coherence Interferometry (LCI) measurement beam is aligned with the eye’s optical axis, for precise measurements of anterior eye chamber distances. The eye follows a fixation target in order to make the visual axis align with the optical axis. Performance problems occurred, however, at this step. Therefore, there was a necessity to develop a new procedure that ensures better alignment between the eye’s visual and optical axes, allowing a more user friendly and versatile procedure, and eventually automatizing the whole process. With this instrument, the alignment between the eye’s optical and visual axes is detected when Purkinje reflections I and III are overlapped, as the eye follows a fixation target. In this project, image analysis is used to detect these Purkinje reflections’ positions, eventually automatically detecting when they overlap. Automatic detection of the third Purkinje reflection of an eye following a fixation target is possible with some restrictions. Each pair of detected third Purkinje reflections is used in automatically calculating an acceptable starting position for the fixation target, required for precise measurements of anterior eye chamber distances.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Release of chloroethene compounds into the environment often results in groundwater contamination, which puts people at risk of exposure by drinking contaminated water. cDCE (cis-1,2-dichloroethene) accumulation on subsurface environments is a common environmental problem due to stagnation and partial degradation of other precursor chloroethene species. Polaromonas sp. strain JS666 apparently requires no exotic growth factors to be used as a bioaugmentation agent for aerobic cDCE degradation. Although being the only suitable microorganism found capable of such, further studies are needed for improving the intrinsic bioremediation rates and fully comprehend the metabolic processes involved. In order to do so, a metabolic model, iJS666, was reconstructed from genome annotation and available bibliographic data. FVA (Flux Variability Analysis) and FBA (Flux Balance Analysis) techniques were used to satisfactory validate the predictive capabilities of the iJS666 model. The iJS666 model was able to predict biomass growth for different previously tested conditions, allowed to design key experiments which should be done for further model improvement and, also, produced viable predictions for the use of biostimulant metabolites in the cDCE biodegradation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The spinning rotor gauge (SRG) is one of the most interesting vacuum gauges ever made, covering a pressure range of over seven orders of magnitude, with minimal gas interference (no pumping, ionization or heating of the measured gas), and a great stability of less than 1% drift per year. But despite its remarkable properties, apparently the SRG has not been further developed since the eighties, when it gained commercial interest. In this context, this dissertation aims at providing a starting point for a new line of investigation regarding this instrument, focused on the rotor itself. A brief study of different rotor geometries is provided, including a comparison between a cylindrical rotor and a spherical one. A cylindrical spinning rotor gauge (CSRG) is then proposed, based on the original SRG, but requiring a completely new lateral damping system. A prototype was built and tested against a non calibrated reference gauge.