7 resultados para modelo linear com resposta em platô


Relevância:

100.00% 100.00%

Publicador:

Resumo:

RESUMO: Este trabalho teve como objetivo a determinação de esquemas de tratamento alternativos para o carcinoma da próstata com radioterapia externa (EBRT) e braquiterapia de baixa taxa de dose (LDRBT) com implantes permanentes de Iodo-125, biologicamente equivalentes aos convencionalmente usados na prática clínica, com recurso a modelos teóricos e a métodos de Monte Carlo (MC). Os conceitos de dose biológica efetiva (BED) e de dose uniforme equivalente (EUD) foram utilizados, com o modelo linear-quadrático (LQ), para a determinação de regimes de tratamento equivalentes. Numa primeira abordagem, utilizou-se a BED para determinar: 1) esquemas hipofracionados de EBRT mantendo as complicações retais tardias de regimes convencionais com doses totais de 75,6 Gy, 77,4 Gy, 79,2 Gy e 81,0 Gy; e 2) a relação entre as doses totais de EBRT e LDRBT de modo a manter a BED do regime convencional de 45 Gy de EBRT e 110 Gy de LDRBT. Numa segunda abordagem, recorreu-se ao código de MC MCNPX para a simulação de distribuições de dose de EBRT e LDRBT em dois fantomas de voxel segmentados a partir das imagens de tomografia computorizada de pacientes com carcinoma da próstata. Os resultados das simulações de EBRT e LDRBT foram somados e determinada uma EUD total de forma a obterem-se: 1) esquemas equivalentes ao tratamento convencional de 25 frações de 1,8 Gy de EBRT em combinação com 110 Gy de LDRBT; e 2) esquemas equivalentes a EUD na próstata de 67 Gy, 72 Gy, 80 Gy, 90 Gy, 100 Gy e 110 Gy. Em todos os resultados nota-se um ganho terapêutico teórico na utilização de esquemas hipofracionados de EBRT. Para uma BED no reto equivalente ao esquema convencional, tem-se um aumento de 2% na BED da próstata com menos 5 frações. Este incremento dá-se de forma cada vez mais visível à medida que se reduz o número de frações, sendo da ordem dos 10-11% com menos 20 frações e dos 35-45% com menos 40 frações. Considerando os resultados das simulações de EBRT, obteve-se uma EUD média de 107 Gy para a próstata e de 42 Gy para o reto, com o esquema convencional de 110 Gy de LDRBT, seguidos de 25 frações de 1,8 Gy de EBRT. Em termos de probabilidade de controlo tumoral (igual EUD), é equivalente a este tratamento a administração de EBRT em 66 frações de 1,8 Gy, 56 de 2 Gy, 40 de 2,5 Gy, 31 de 3 Gy, 20 de 4 Gy ou 13 de 5 Gy. Relativamente à administração de 66 frações de 1,8 Gy, a EUD generalizada no reto reduz em 6% com o recurso a frações de 2,5 Gy e em 10% com frações de 4 Gy. Determinou-se uma BED total de 162 Gy para a administração de 25 frações de 1,8 Gy de EBRT em combinação com 110 Gy de LDRBT. Variando-se a dose total de LDRBT (TDLDRBT) em função da dose total de EBRT (TDEBRT), de modo a garantir uma BED de 162 Gy, obteve-se a seguinte relação:.......... Os resultados das simulações mostram que a EUD no reto diminui com o aumento da dose total de LDRBT para dose por fração de EBRT (dEBRT) inferiores a 2, Gy e aumenta para dEBRT a partir dos 3 Gy. Para quantidades de TDLDRBT mais baixas (<50 Gy), o reto beneficia de frações maiores de EBRT. À medida que se aumenta a TDLDRBT, a EUD generalizada no reto torna-se menos dependente da dEBRT. Este trabalho mostra que é possível a utilização de diferentes regimes de tratamento para o carcinoma da próstata com radioterapia que possibilitem um ganho terapêutico, quer seja administrando uma maior dose biológica com efeitos tardios constantes, quer mantendo a dose no tumor e diminuindo a toxicidade retal. A utilização com precaução de esquemas hipofracionados de EBRT, para além do benefício terapêutico, pode trazer vantagens ao nível da conveniência para o paciente e economia de custos. Os resultados das simulações deste estudo e conversão para doses de efeito biológico para o tratamento do carcinoma da próstata apresentam linhas de orientação teórica de interesse para novos ensaios clínicos. --------------------------------------------------ABSTRACT: The purpose of this work was to determine alternative radiotherapy regimens for the treatment of prostate cancer using external beam radiotherapy (EBRT) and low dose-rate brachytherapy (LDRBT) with Iodine-125 permanent implants which are biologically equivalent to conventional clinical treatments, by the use of theoretical models and Monte Carlo techniques. The concepts of biological effective dose (BED) and equivalent uniform dose (EUD), together with the linear-quadratic model (LQ), were used for determining equivalent treatment regimens. In a first approach, the BED concept was used to determine: 1) hypofractionated schemes of EBRT maintaining late rectal complications as with the conventional regimens with total doses of 75.6 Gy, 77.4 Gy, 79.2 Gy and 81.0 Gy; and 2) the relationship between total doses of EBRT and LDRBT in order to keep the BED of the conventional treatment of 45 Gy of EBRT and 110 Gy of LDRBT. In a second approach, the MC code MCNPX was used for simulating dose distributions of EBRT and LDRBT in two voxel phantoms segmented from the computed tomography of patients with prostate cancer. The results of the simulations of EBRT and LDRBT were added up and given an overall EUD in order to obtain: 1) equivalent to conventional treatment regimens of 25 fraction of 1.8 Gy of EBRT in combination with 110Gy of LDRBT; and 2) equivalent schemes of EUD of 67 Gy, 72 Gy, 80 Gy, 90 Gy, 100 Gy, and 110Gy to the prostate. In all the results it is noted a therapeutic gain using hypofractionated EBRT schemes. For a rectal BED equivalent to the conventional regimen, an increment of 2% in the prostate BED was achieved with less 5 fractions. This increase is visibly higher as the number of fractions decrease, amounting 10-11% with less 20 fractions and 35-45% with less 20 fractions. Considering the results of the EBRT simulations an average EUD of 107 Gy was achieved for the prostate and of 42 Gy for the rectum with the conventional scheme of 110 Gy of LDRBT followed by 25 fractions of 1.8 Gy of EBRT. In terms of tumor control probability (same EUD) it is equivalent to this treatment, for example, delivering the EBRT in 66 fractions of 1.8 Gy, 56 fractions of 2 Gy, 40 fractions of 2.5 Gy, 31 fractions of 3 Gy, 20 fractions of 4 Gy or 13 fractions of 5 Gy. Regarding the use of 66 fractions of 1.8 Gy, the rectum EUD is reduced to 6% with 2.5 Gy per fraction and to 10% with 4 Gy. A total BED of 162 Gy was achieved for the delivery of 25 fractions of 1.8 Gy of EBRT in combination with 110 Gy of LDRBT. By varying the total dose of LDRBT (TDLDRBT) with the total dose of EBRT (TDEBRT) so as to ensure a BED of 162 Gy, the following relationship was obtained: ....... The simulation results show that the rectum EUD decreases with the increase of the TDLDRBT, for EBRT dose per fracion (dEBRT) less than 2.5 Gy and increases for dEBRT above 3 Gy. For lower amounts of TDLDRBT (< 50Gy), the rectum benefits of larger EBRT fractions. As the TDLDRBT increases, the rectum gEUD becomes less dependent on the dEBRT. The use of different regimens which enable a therapeutic gain, whether deivering a higher dose with the same late biological effects or maintaining the dose to the tumor and reducing rectal toxicity is possible. The use with precaution of hypofractionated regimens, in addition to the therapeutic benefit, can bring advantages in terms of convenience for the patient and cost savings. The simulation results of this study together with the biological dose conversion for the treatment of prostate cancer serve as guidelines of interest for new clinical trials.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A schistosomose é uma doença parasitária que afecta cerca de 200 milhões de pessoas, com alta prevalência nos trópicos e que origina um grave problema de saúde pública. Ao longo da infecção, o sistema imunitário tenta de várias formas combater a presença do parasita. Inicialmente ocorre uma resposta imune mediada por células do tipo Th1, com o progresso da infecção, a resposta é substituída por uma resposta do tipo Th2 induzida durante a formação de granulomas. Este surge como resposta à presença de produtos tóxicos libertados pelos ovos do parasita retido nos tecidos. O fígado é o principal alvo do depósito de ovos, sofrendo alterações fisiopatológicas, e histológicas. O Mus musculus tem sido muito utilizados na infecção experimental por Schistosoma mansoni, para melhor se conhecer o papel da resposta imunitária na formação de granulomas hepáticos. No decorrer da infecção o granuloma sofre alterações desencadeadas pelas citocinas que o sistema imunitário produz. Estas alterações dividem-se em cinco fases: reacção inicial, exsudativa, exsudativa-produtiva, produtiva e involutiva granuloma. O presente trabalho, estudou as alterações sofridas pelo granuloma hepático (quantidade, dimensão e fase do granuloma), em três diferentes períodos de infecção (55, 90 e 125 dias) no modelo animal Mus musculus infectado com Schistosoma. mansoni, estirpe SmBh distribuídos por três grupos experimentais com diferente número de cercárias (50, 80, e 100). Verificou-se que ao longo da infecção a quantidade de granulomas aumenta, as dimensões têm uma tendência inicial para aumentar mas a partir dos 90 dias após a exposição sofrem uma diminuição. No grupo experimental com maior intensidade de infecção inicial a diminuição deu-se mais cedo. Em relação às fases de desenvolvimento do granuloma este sofre alterações ao longo de toda a infecção. Assim, aos 55 dias predomina a fase exsudativa, aos 90 todos os grupos apresentam maior percentagem de granulomas na fase produtiva e por fim aos 125 dias prevalece a fase involutiva. Todos estes resultados sugerem que a caracterização do granuloma nas diferentes fases de infecção pode depender do número de cercárias da exposição.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dissertação apresentada para cumprimento dos requisitos necessários à obtenção do grau de Mestre em Ecologia Humana e Problemas Sociais Contemporâneos

Relevância:

30.00% 30.00%

Publicador:

Resumo:

O presente relatório visa dar conta de como, hoje, se concebem, organizam e se articulam as estruturas de Defesa, Segurança e Proteção Civil a nível municipal (município de Lisboa). Trata‐se de um novo modelo integrado de Segurança, Proteção e Socorro que agrega meios de coordenação e de decisão num único espaço. Com a implementação deste modelo, pretende‐se que as Forças de Segurança, Proteção e Socorro das cidades, suportadas por um sistema único de comunicações de acionamento de meios das respetivas estruturas, possam garantir uma resposta operacional mais célere e coordenada. Relevam‐se também neste modelo a dimensão infra‐estrutural, a estratégia de intervenção, associada à dimensão humana nos planos de atuação individual, local e Municipal e a importância que os exercícios/simulacros fornecem às forças de intervenção, aos Agentes de Proteção Civil (APC) e ao público em geral. Este modelo, porque assenta em processos de co‐construção de decisões e porque respeita as variáveis de contexto, poderá constituir um referencial e um guia importante para as cidades capitais de Língua Portuguesa, que integram a União das Cidades Capitais de Língua Portuguesa (UCCLA), enquanto fator motivador de desenvolvimento sustentado.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

ABSTRACT Background Mental health promotion is supported by a strong body of knowledge and is a matter of public health with the potential of a large impact on society. Mental health promotion programs should be implemented as soon as possible in life, preferably starting during pregnancy. Programs should focus on malleable determinants, introducing strategies to reduce risk factors or their impact on mother and child, and also on strengthening protective factors to increase resilience. The ambition of early detecting risk situations requires the development and use of tools to assess risk, and the creation of a responsive network of services based in primary health care, especially maternal consultation during pregnancy and the first months of the born child. The number of risk factors and the way they interact and are buffered by protective factors are relevant for the final impact. Maternal-fetal attachment (MFA) is not yet a totally understood and well operationalized concept. Methodological problems limit the comparison of data as many studies used small size samples, had an exploratory character or used different selection criteria and different measures. There is still a lack of studies in high risk populations evaluating the consequences of a weak MFA. Instead, the available studies are not very conclusive, but suggest that social support, anxiety and depression, self-esteem and self-control and sense of coherence are correlated with MFA. MFA is also correlated with health practices during pregnancy, that influence pregnancy and baby outcomes. MFA seems a relevant concept for the future mother baby interaction, but more studies are needed to clarify the concept and its operationalization. Attachment is a strong scientific concept with multiple implications for future child development, personality and relationship with others. Secure attachment is considered an essential basis of good mental health, and promoting mother-baby interaction offers an excellent opportunity to intervention programmes targeted at enhancing mental health and well-being. Understanding the process of attachment and intervening to improve attachment requires a comprehension of more proximal factors, but also a broader approach that assesses the impact of more distal social conditions on attachment and how this social impact is mediated by family functioning and mother-baby interaction. Finally, it is essential to understand how this knowledge could be translated in effective mental health promoting interventions and measures that could reach large populations of pregnant mothers and families. Strengthening emotional availability (EA) seems to be a relevant approach to improve the mother-baby relationship. In this review we have offered evidence suggesting a range of determinants of mother-infant relationship, including age, marital relationship, social disadvantages, migration, parental psychiatric disorders and the situations of abuse or neglect. Based on this theoretical background we constructed a theoretical model that included proximal and distal factors, risk and protective factors, including variables related to the mother, the father, their social support and mother baby interaction from early pregnancy until six months after birth. We selected the Antenatal Psychosocial Health Assessment (ALPHA) for use as an instrument to detect psychosocial risk during pregnancy. Method Ninety two pregnant women were recruited from the Maternal Health Consultation in Primary Health Care (PHC) at Amadora. They had three moments of assessment: at T1 (until 12 weeks of pregnancy) they filed out a questionnaire that included socio-demographic data, ALPHA, Edinburgh post-natal Depression Scale (EDPS), General Health Questionnaire (GHQ) and Sense of Coherence (SOC); at T2 (after the 20th weeks of pregnancy) they answered EDPS, SOC and MFA Scale (MFAS), and finally at T3 (6 months after birth), they repeated EDPS and SOC, and their interaction with their babies was videotaped and later evaluated using EA Scales. A statistical analysis has been done using descriptive statistics, correlation analysis, univariate logistic regression and multiple linear regression. Results The study has increased our knowledge on this particular population living in a multicultural, suburb community. It allow us to identify specific groups with a higher level of psychosocial risk, such as single or divorced women, young couples, mothers with a low level of education and those who are depressed or have a low SOC. The hypothesis that psychosocial risk is directly correlated with MFAS and that MFA is directly correlated with EA was not confirmed, neither the correlation between prenatal psychosocial risk and mother-baby EA. The study identified depression as a relevant risk factor in pregnancy and its higher prevalence in single or divorced women, immigrants and in those who have a higher global psychosocial risk. Depressed women have a poor MFA, and a lower structuring capacity and a higher hostility to their babies. In average, depression seems to reduce among pregnant women in the second part of their pregnancy. The children of immigrant mothers show a lower level of responsiveness to their mothers what could be transmitted through depression, as immigrant mothers have a higher risk of depression in the beginning of pregnancy and six months after birth. Young mothers have a low MFA and are more intrusive. Women who have a higher level of education are more sensitive and their babies showed to be more responsive. Women who are or have been submitted to abuse were found to have a higher level of MFA but their babies are less responsive to them. The study highlights the relevance of SOC as a potential protective factor while it is strongly and negatively related with a wide range of risk factors and mental health outcomes especially depression before, during and after pregnancy. Conclusions ALPHA proved to be a valid, feasible and reliable instrument to Primary Health Care (PHC) that can be used as a total sum score. We could not prove the association between psychosocial risk factors and MFA, neither between MFA and EA, or between psychosocial risk and EA. Depression and SOC seems to have a clear and opposite relevance on this process. Pregnancy can be considered as a maturational process and an opportunity to change, where adaptation processes occur, buffering risk, decreasing depression and increasing SOC. Further research is necessary to better understand interactions between variables and also to clarify a better operationalization of MFA. We recommend the use of ALPHA, SOC and EDPS in early pregnancy as a way of identifying more vulnerable women that will require additional interventions and support in order to decrease risk. At political level we recommend the reinforcement of Immigrant integration and the increment of education in women. We recommend more focus in health care and public health in mental health condition and psychosocial risk of specific groups at high risk. In PHC special attention should be paid to pregnant women who are single or divorced, very young, low educated and to immigrant mothers. This study provides the basis for an intervention programme for this population, that aims to reduce broad spectrum risk factors and to promote Mental Health in women who become pregnant. Health and mental health policies should facilitate the implementation of the suggested measures.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

RESUMO: O cancro de mama e o mais frequente diagnoticado a indiv duos do sexo feminino. O conhecimento cientifico e a tecnologia tem permitido a cria ção de muitas e diferentes estrat egias para tratar esta patologia. A Radioterapia (RT) est a entre as diretrizes atuais para a maioria dos tratamentos de cancro de mama. No entanto, a radia ção e como uma arma de dois canos: apesar de tratar, pode ser indutora de neoplasias secund arias. A mama contralateral (CLB) e um orgão susceptivel de absorver doses com o tratamento da outra mama, potenciando o risco de desenvolver um tumor secund ario. Nos departamentos de radioterapia tem sido implementadas novas tecnicas relacionadas com a radia ção, com complexas estrat egias de administra ção da dose e resultados promissores. No entanto, algumas questões precisam de ser devidamente colocadas, tais como: E seguro avançar para tecnicas complexas para obter melhores indices de conformidade nos volumes alvo, em radioterapia de mama? O que acontece aos volumes alvo e aos tecidos saudaveis adjacentes? Quão exata e a administração de dose? Quais são as limitações e vantagens das técnicas e algoritmos atualmente usados? A resposta a estas questões e conseguida recorrendo a m etodos de Monte Carlo para modelar com precisão os diferentes componentes do equipamento produtor de radia ção(alvos, ltros, colimadores, etc), a m de obter uma descri cão apropriada dos campos de radia cão usados, bem como uma representa ção geometrica detalhada e a composição dos materiais que constituem os orgãos e os tecidos envolvidos. Este trabalho visa investigar o impacto de tratar cancro de mama esquerda usando diferentes tecnicas de radioterapia f-IMRT (intensidade modulada por planeamento direto), IMRT por planeamento inverso (IMRT2, usando 2 feixes; IMRT5, com 5 feixes) e DCART (arco conformacional dinamico) e os seus impactos em irradia ção da mama e na irradia ção indesejada dos tecidos saud aveis adjacentes. Dois algoritmos do sistema de planeamento iPlan da BrainLAB foram usados: Pencil Beam Convolution (PBC) e Monte Carlo comercial iMC. Foi ainda usado um modelo de Monte Carlo criado para o acelerador usado (Trilogy da VARIAN Medical Systems), no c odigo EGSnrc MC, para determinar as doses depositadas na mama contralateral. Para atingir este objetivo foi necess ario modelar o novo colimador multi-laminas High- De nition que nunca antes havia sido simulado. O modelo desenvolvido est a agora disponí vel no pacote do c odigo EGSnrc MC do National Research Council Canada (NRC). O acelerador simulado foi validado com medidas realizadas em agua e posteriormente com c alculos realizados no sistema de planeamento (TPS).As distribui ções de dose no volume alvo (PTV) e a dose nos orgãos de risco (OAR) foram comparadas atrav es da an alise de histogramas de dose-volume; an alise estati stica complementar foi realizadas usando o software IBM SPSS v20. Para o algoritmo PBC, todas as tecnicas proporcionaram uma cobertura adequada do PTV. No entanto, foram encontradas diferen cas estatisticamente significativas entre as t ecnicas, no PTV, nos OAR e ainda no padrão da distribui ção de dose pelos tecidos sãos. IMRT5 e DCART contribuem para maior dispersão de doses baixas pelos tecidos normais, mama direita, pulmão direito, cora cão e at e pelo pulmão esquerdo, quando comparados com as tecnicas tangenciais (f-IMRT e IMRT2). No entanto, os planos de IMRT5 melhoram a distribuição de dose no PTV apresentando melhor conformidade e homogeneidade no volume alvo e percentagens de dose mais baixas nos orgãos do mesmo lado. A t ecnica de DCART não apresenta vantagens comparativamente com as restantes t ecnicas investigadas. Foram tamb em identi cadas diferen cas entre os algoritmos de c alculos: em geral, o PBC estimou doses mais elevadas para o PTV, pulmão esquerdo e cora ção, do que os algoritmos de MC. Os algoritmos de MC, entre si, apresentaram resultados semelhantes (com dferen cas at e 2%). Considera-se que o PBC não e preciso na determina ção de dose em meios homog eneos e na região de build-up. Nesse sentido, atualmente na cl nica, a equipa da F sica realiza medi ções para adquirir dados para outro algoritmo de c alculo. Apesar de melhor homogeneidade e conformidade no PTV considera-se que h a um aumento de risco de cancro na mama contralateral quando se utilizam t ecnicas não-tangenciais. Os resultados globais dos estudos apresentados confirmam o excelente poder de previsão com precisão na determinação e c alculo das distribui ções de dose nos orgãos e tecidos das tecnicas de simulação de Monte Carlo usados.---------ABSTRACT:Breast cancer is the most frequent in women. Scienti c knowledge and technology have created many and di erent strategies to treat this pathology. Radiotherapy (RT) is in the actual standard guidelines for most of breast cancer treatments. However, radiation is a two-sword weapon: although it may heal cancer, it may also induce secondary cancer. The contralateral breast (CLB) is a susceptible organ to absorb doses with the treatment of the other breast, being at signi cant risk to develop a secondary tumor. New radiation related techniques, with more complex delivery strategies and promising results are being implemented and used in radiotherapy departments. However some questions have to be properly addressed, such as: Is it safe to move to complex techniques to achieve better conformation in the target volumes, in breast radiotherapy? What happens to the target volumes and surrounding healthy tissues? How accurate is dose delivery? What are the shortcomings and limitations of currently used treatment planning systems (TPS)? The answers to these questions largely rely in the use of Monte Carlo (MC) simulations using state-of-the-art computer programs to accurately model the di erent components of the equipment (target, lters, collimators, etc.) and obtain an adequate description of the radiation elds used, as well as the detailed geometric representation and material composition of organs and tissues. This work aims at investigating the impact of treating left breast cancer using di erent radiation therapy (RT) techniques f-IMRT (forwardly-planned intensity-modulated), inversely-planned IMRT (IMRT2, using 2 beams; IMRT5, using 5 beams) and dynamic conformal arc (DCART) RT and their e ects on the whole-breast irradiation and in the undesirable irradiation of the surrounding healthy tissues. Two algorithms of iPlan BrainLAB TPS were used: Pencil Beam Convolution (PBC)and commercial Monte Carlo (iMC). Furthermore, an accurate Monte Carlo (MC) model of the linear accelerator used (a Trilogy R VARIANR) was done with the EGSnrc MC code, to accurately determine the doses that reach the CLB. For this purpose it was necessary to model the new High De nition multileaf collimator that had never before been simulated. The model developed was then included on the EGSnrc MC package of National Research Council Canada (NRC). The linac was benchmarked with water measurements and later on validated against the TPS calculations. The dose distributions in the planning target volume (PTV) and the dose to the organs at risk (OAR) were compared analyzing dose-volume histograms; further statistical analysis was performed using IBM SPSS v20 software. For PBC, all the techniques provided adequate coverage of the PTV. However, statistically significant dose di erences were observed between the techniques, in the PTV, OAR and also in the pattern of dose distribution spreading into normal tissues. IMRT5 and DCART spread low doses into greater volumes of normal tissue, right breast, right lung, heart and even the left lung than tangential techniques (f-IMRT and IMRT2). However,IMRT5 plans improved distributions for the PTV, exhibiting better conformity and homogeneity in target and reduced high dose percentages in ipsilateral OAR. DCART did not present advantages over any of the techniques investigated. Di erences were also found comparing the calculation algorithms: PBC estimated higher doses for the PTV, ipsilateral lung and heart than the MC algorithms predicted. The MC algorithms presented similar results (within 2% di erences). The PBC algorithm was considered not accurate in determining the dose in heterogeneous media and in build-up regions. Therefore, a major e ort is being done at the clinic to acquire data to move from PBC to another calculation algorithm. Despite better PTV homogeneity and conformity there is an increased risk of CLB cancer development, when using non-tangential techniques. The overall results of the studies performed con rm the outstanding predictive power and accuracy in the assessment and calculation of dose distributions in organs and tissues rendered possible by the utilization and implementation of MC simulation techniques in RT TPS.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Recaí sob a responsabilidade da Marinha Portuguesa a gestão da Zona Económica Exclusiva de Portugal, assegurando a sua segurança da mesma face a atividades criminosas. Para auxiliar a tarefa, é utilizado o sistema Oversee, utilizado para monitorizar a posição de todas as embarcações presentes na área afeta, permitindo a rápida intervenção da Marinha Portuguesa quando e onde necessário. No entanto, o sistema necessita de transmissões periódicas constantes originadas nas embarcações para operar corretamente – casos as transmissões sejam interrompidas, deliberada ou acidentalmente, o sistema deixa de conseguir localizar embarcações, dificultando a intervenção da Marinha. A fim de colmatar esta falha, é proposto adicionar ao sistema Oversee a capacidade de prever as posições futuras de uma embarcação com base no seu trajeto até à cessação das transmissões. Tendo em conta os grandes volumes de dados gerados pelo sistema (históricos de posições), a área de Inteligência Artificial apresenta uma possível solução para este problema. Atendendo às necessidades de resposta rápida do problema abordado, o algoritmo de Geometric Semantic Genetic Programming baseado em referências de Vanneschi et al. apresenta-se como uma possível solução, tendo já produzido bons resultados em problemas semelhantes. O presente trabalho de tese pretende integrar o algoritmo de Geometric Semantic Genetic Programming desenvolvido com o sistema Oversee, a fim de lhe conceder capacidades preditivas. Adicionalmente, será realizado um processo de análise de desempenho a fim de determinar qual a ideal parametrização do algoritmo. Pretende-se com esta tese fornecer à Marinha Portuguesa uma ferramenta capaz de auxiliar o controlo da Zona Económica Exclusiva Portuguesa, permitindo a correta intervenção da Marinha em casos onde o atual sistema não conseguiria determinar a correta posição da embarcação em questão.