46 resultados para force sensor calibration


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Micro/nano wrinkled patterns on cross-linked urethane/urea polymeric flexible free standing films with two soft segments, polypropylene oxide and polybutadiene, can be induced by UV-irradiation. The ability to write/erase these 3D structures, in a controlled manner, is the main focus of this work. The imprinting of the wrinkled structures was accomplished by swelling in an appropriate solvent followed by drying the membranes after the cross-linking process and UV irradiation. The surface tailoring of the elastomeric membranes was imaged by optical microscopy, scanning electronic microscopy and by atomic force microscopy. To erase the wrinkled structures the elastomers were swollen. The swelling as well as the sol/gel fraction and the UV radiation were tuned in order to control the wrinkles characteristics. It was found that the wrinkles wavelength, in the order of microns (1±0,25μm), was stamped by the UV radiation intensity and exposure time while the wrinkles' amplitude, in the order of nanometers (150-450 nm), was highly dependent on the swelling and sol/gel fraction. A prototype for volatile organic compounds detection was developed taking advantage of the unique 3D micro/nano wrinkles features.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The “CMS Safety Closing Sensors System” (SCSS, or CSS for brevity) is a remote monitoring system design to control safety clearance and tight mechanical movements of parts of the CMS detector, especially during CMS assembly phases. We present the different systems that makes SCSS: its sensor technologies, the readout system, the data acquisition and control software. We also report on calibration and installation details, which determine the resolution and limits of the system. We present as well our experience from the operation of the system and the analysis of the data collected since 2008. Special emphasis is given to study positioning reproducibility during detector assembly and understanding how the magnetic fields influence the detector structure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Gestão e Sistemas Ambientais

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Instrumentação, Manutenção Industrial e Qualidade

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electronics Letters Vol.38, nº 19

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Journal of Applied Physics, Vol. 96, nº3

Relevância:

20.00% 20.00%

Publicador:

Resumo:

IEEE International Symposium on Circuits and Systems, pp. 232 – 235, Seattle, EUA

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Proceedings of IEEE, ISCAS 2003, Vol.I, pp. 877-880

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para a obtenção do grau de Mestre em Engenharia Electrotécnica e de Computadores

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada para obtenção do grau de Mestre em Bioquímica Estrutural e Funcional, pela Universidade Nova de Lisboa, Faculdade de Ciências e Tecnologia

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada à Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para complementar os requerimentos para a obtenção do grau de Mestre em Engenharia Biomédica

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of the article is to evaluate the impact of the friction force mouse-pad in the contraction level of the forearm muscles M. extensor carpi ulnaris, M. extensor digitorum and M. extensor carpi radialis longus. A standard protocol of mouse movements was performed involving horizontal, vertical and diagonal mouse displacements drag-and-drop type. The operators were instructed to execute the protocol with their normal working speed. The movements protocol were performed by each subject (n=17) with three selected pairs mouse-pad, classified as low, medium and high friction force pairs. The mean time to execute the protocol with each mouse was ~138s. Mean values of ~13%MVE and ~17%MVE were found in the M. extensor carpi ulnaris and in the M. extensor digitorum respectively when performing the movements’ protocol. A 8.1% increase in %MVE was observed in the M. extensor digitorum and a 9.4% increase in %MVE was observed in the M. extensor carpi ulnaris when the high friction force pair was operated, relatively to the low friction force pair (p<0.05). The main preliminary conclusions of this study is that operating a high friction force mouse-pad may increase the risk to symptoms or disorders in the wrist due to an increase in the forearm muscles contraction levels, particularly during work with drawing application

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia Biomédica

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Bioorgânica