10 resultados para controlled active front end rectifier


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia Eletrotécnica e de Computadores, pela Universidade Nova de Ciências e Tecnologia

Relevância:

100.00% 100.00%

Publicador:

Resumo:

IEEE International Symposium on Circuits and Systems, pp. 2258 – 2261, Seattle, EUA

Relevância:

100.00% 100.00%

Publicador:

Resumo:

15th IEEE International Conference on Electronics, Circuits and Systems, Malta

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Breast cancer is the most common type of cancer worldwide. The effectiveness of its treatment depends on early stage detection, as well as on the accuracy of its diagnosis. Recently, diagnosis techniques have been submitted to relevant breakthroughs with the upcoming of Magnetic Resonance Imaging, Ultrasound Sonograms and Positron Emission Tomography (PET) scans, among others. The work presented here is focused on studying the application of a PET system to a Positron Emission Mammography (PEM) system. A PET/PEM system works under the principle that a scintillating crystal will detect a gamma-ray pulse, originated at the cancerous cells, converting it into a correspondent visible light pulse. The latter must then be converted into an electrical current pulse by means of a Photo- -Sensitive Device (PSD). After the PSD there must be a Transimpedance Amplifier (TIA) in order to convert the current pulse into a suitable output voltage, in a time period lower than 40 ns. In this Thesis, the PSD considered is a Silicon Photo-Multiplier (SiPM). The usage of this recently developed type of PSD is impracticable with the conventional TIA topologies, as it will be proven. Therefore, the usage of the Regulated Common-Gate (RCG) topology will be studied in the design of the amplifier. There will be also presented two RCG variations, comprising a noise response improvement and differential operation of the circuit. The mentioned topology will also be tested in a Radio-Frequency front-end, showing the versatility of the RCG. A study comprising a low-voltage self-biasing feedback TIA will also be shown. The proposed circuits will be simulated with standard CMOS technology (UMC 130 nm), using a 1.2 V power supply. A power consumption of 0.34 mW with a signal-to-noise ratio of 43 dB was achieved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this thesis a CMOS low-power and low-voltage RF receiver front-end is presented. The main objective is to design this RF receiver so that it can be powered by a piezoelectric energy harvesting power source, included in a Wireless Sensor Node application. For this type of applications the major requirements are: the low-power and low-voltage operation, the reduced area and cost and the simplicity of the architecture. The system key blocks are the LNA and the mixer, which are studied and optimized with greater detail, achieving a good linearity, a wideband operation and a reduced introduction of noise. A wideband balun LNA with noise and distortion cancelling is designed to work at a 0.6 V supply voltage, in conjunction with a double-balanced passive mixer and subsequent TIA block. The passive mixer operates in current mode, allowing a minimal introduction of voltage noise and a good linearity. The receiver analog front-end has a total voltage conversion gain of 31.5 dB, a 0.1 - 4.3 GHz bandwidth, an IIP3 value of -1.35 dBm, and a noise figure lower than 9 dB. The total power consumption is 1.9 mW and the die area is 305x134.5 m2, using a standard 130 nm CMOS technology.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dissertação apresentada na faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para a obtenção do grau de Mestre em Engenharia Electrotécnica e de Computadores

Relevância:

30.00% 30.00%

Publicador:

Resumo:

RESUMO: Relevância e Objectivos: O objectivo deste estudo consistiu em verificar a eficácia e segurança de uma técnica de higiene brônquica – Active Cycle breathing technique (ACBT), na remoção de secreções e desinsuflação em crianças asmáticas. É uma técnica recente, que ainda não foi estudada nesta população. Metodologia: A amostra foi constituída por um total de 14 crianças, com idades compreendidas entre os 6 e 18 anos, com o diagnóstico de asma. Foi dividida em dois grupos: grupo de controlo, constituído por asmáticos estáveis e grupo experimental constituído por asmáticos pós-crise. Ambos receberam o mesmo tratamento, que consistiu numa única sessão de ACBT. Realizaram um exame da função respiratória (variáveis FEV1, PEF, MEF75%, RV e FRC) antes e após a aplicação da técnica. Mediu-se a Saturação de O2 antes, a meio e no fim da aplicação da técnica. Por último, pesaram-se as secreções recolhidas durante a sessão de tratamento. Resultados: Como resultados, quando omparamos o antes e após aplicação do ACBT, obtivemos diferenças significativas no RV (p <0,05) e FRC (p <0,05); muito significativa na Sa02 (p <0,01) e peso de secreções, nos asmáticos pós crise. Ocorreu uma melhoria significativa da saturação (p <0,05) em asmáticos estáveis, não havendo secreções. Não houve efeitos adversos nem broncoespasmo em ambos os grupos.Conclusão: O ACBT é uma técnica que promove a remoção de secreções e diminuição da insuflação na população de asmáticos.--------------------ABSTRACT:Relevance and Goals: the goal of this study was to verify the efficiency and security of a bronchial hygienic technique - Active Cycle Breathing Technique (ACBT) – in the obstruction and insufflation of asthmatic children. This is a new technique that has not yet been studied in this population. Procedures: The subjects were 14 children aged between 6 and 18 years old with asthma diagnosis. They were divided in two groups: the control group with stable asthmatics and the experimental group with post-crisis asthmatics. Both received the same treatment that was a single session of ACBT. They made a lung function test before and after the application of the technique (variables FEV1, PEF, MEF75%, RV and FRC). The level of O2 saturation was measured before, during and after the procedure. In the end, the secretions collected during the treatment were weighted. Results: We observed a significant difference on RV (p ˂0,05), FRC (p ˂0,05), Sa02 (p ˂0,01) and in the weight of the secretions in the post-crisis asthmatics after ACBT. There was a significant improvement of saturation (p ˂0,05) only in the stable asthmatics. There were no adverse effects or bronchospasm in both groups.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The work presented in this thesis was developed in collaboration with a Portuguese company, BeyonDevices, devoted to pharmaceutical packaging, medical technology and device industry. Specifically, the composition impact and surface modification of two polymeric medical devices from the company were studied: inhalers and vaginal applicators. The polyethylene-based vaginal applicator was modified using supercritical fluid technology to acquire self-cleaning properties and prevent the transport of bacteria and yeasts to vaginal flora. For that, in-situ polymerization of 2-substituted oxazolines was performed within the polyethylene matrix using supercritical carbon dioxide. The cationic ring-opening polymerization process was followed by end-capping with N,N-dimethyldodecylamine. Furthermore, for the same propose, the polyethylene matrix was impregnated with lavender oil in supercritical medium. The obtained materials were characterized physical and morphologically and the antimicrobial activity against bacteria and yeasts was accessed. Materials modified using 2-substituted oxazolines showed an effective killing ability for all the tested microorganisms, while the materials modified with lavender oil did not show antimicrobial activity. Only materials modified with oligo(2-ethyl-2-oxazoline) maintain the activity during the long term stability. Furthermore, the cytotoxicity of the materials was tested, confirming their biocompatibilty. Regarding the inhaler, its surface was modified in order to improve powder flowability and consequently, to reduce powder retention in the inhaler´s nozzle. New dry powder inhalers (DPIs), with different needle’s diameters, were evaluated in terms of internal resistance and uniformity of the emitted dose. It was observed that they present a mean resistance of 0.06 cmH2O0.5/(L/min) and the maximum emitted dose obtained was 68.9% for the inhaler with higher needle´s diameter (2 mm). Thus, this inhaler was used as a test and modified by the coating with a commonly-used force control agent, magnesium stearate, dried with supercritical carbon dioxide (scCO2) and the uniformity of delivered dose tests were repeated. The modified inhaler showed an increase in emitted dose from 68.9% to 71.3% for lactose and from 30.0% to 33.7% for Foradil.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Modern CMOS radio frequency (RF) Receivers have enabled efficient and increasing applications. The main requirement is to have system in a single chip, in order to minimize area and cost. For the purpose it is required the development of inductorless circuits for the key blocks of an RF receiver. Examples of this key blocks are RC oscillators, RF band pass filters, and Low Noise Amplifiers. The present dissertation presents an inductorless wideband MOSFET-only RF Non-Gyrator Type of Active Inductors with low area, low cost, and very low power, capable of covering the whole WMTS, and ISM, band and intended for biomedical applications. The proposed circuit is based on a floating capacitor connected between two controlled current sources. The first current source, which is controlled by the circuit input voltage, has two objectives: supply current to the capacitor (