11 resultados para Spatial Resolution


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Dissertação para a obtenção do Grau de Mestre em Engenharia Biomédica

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Many municipal activities require updated large-scale maps that include both topographic and thematic information. For this purpose, the efficient use of very high spatial resolution (VHR) satellite imagery suggests the development of approaches that enable a timely discrimination, counting and delineation of urban elements according to legal technical specifications and quality standards. Therefore, the nature of this data source and expanding range of applications calls for objective methods and quantitative metrics to assess the quality of the extracted information which go beyond traditional thematic accuracy alone. The present work concerns the development and testing of a new approach for using technical mapping standards in the quality assessment of buildings automatically extracted from VHR satellite imagery. Feature extraction software was employed to map buildings present in a pansharpened QuickBird image of Lisbon. Quality assessment was exhaustive and involved comparisons of extracted features against a reference data set, introducing cartographic constraints from scales 1:1000, 1:5000, and 1:10,000. The spatial data quality elements subject to evaluation were: thematic (attribute) accuracy, completeness, and geometric quality assessed based on planimetric deviation from the reference map. Tests were developed and metrics analyzed considering thresholds and standards for the large mapping scales most frequently used by municipalities. Results show that values for completeness varied with mapping scales and were only slightly superior for scale 1:10,000. Concerning the geometric quality, a large percentage of extracted features met the strict topographic standards of planimetric deviation for scale 1:10,000, while no buildings were compliant with the specification for scale 1:1000.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Dissertation submitted in partial fulfilment of the requirements for the Degree of Master of Science in Geospatial Technologies

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Thesis submitted to the Instituto Superior de Estatística e Gestão de Informação da Universidade Nova de Lisboa in partial fulfillment of the requirements for the Degree of Doctor of Philosophy in Information Management – Geographic Information Systems

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Doutor em Engenharia do Ambiente

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Nowadays, existing 3D scanning cameras and microscopes in the market use digital or discrete sensors, such as CCDs or CMOS for object detection applications. However, these combined systems are not fast enough for some application scenarios since they require large data processing resources and can be cumbersome. Thereby, there is a clear interest in exploring the possibilities and performances of analogue sensors such as arrays of position sensitive detectors with the final goal of integrating them in 3D scanning cameras or microscopes for object detection purposes. The work performed in this thesis deals with the implementation of prototype systems in order to explore the application of object detection using amorphous silicon position sensors of 32 and 128 lines which were produced in the clean room at CENIMAT-CEMOP. During the first phase of this work, the fabrication and the study of the static and dynamic specifications of the sensors as well as their conditioning in relation to the existing scientific and technological knowledge became a starting point. Subsequently, relevant data acquisition and suitable signal processing electronics were assembled. Various prototypes were developed for the 32 and 128 array PSD sensors. Appropriate optical solutions were integrated to work together with the constructed prototypes, allowing the required experiments to be carried out and allowing the achievement of the results presented in this thesis. All control, data acquisition and 3D rendering platform software was implemented for the existing systems. All these components were combined together to form several integrated systems for the 32 and 128 line PSD 3D sensors. The performance of the 32 PSD array sensor and system was evaluated for machine vision applications such as for example 3D object rendering as well as for microscopy applications such as for example micro object movement detection. Trials were also performed involving the 128 array PSD sensor systems. Sensor channel non-linearities of approximately 4 to 7% were obtained. Overall results obtained show the possibility of using a linear array of 32/128 1D line sensors based on the amorphous silicon technology to render 3D profiles of objects. The system and setup presented allows 3D rendering at high speeds and at high frame rates. The minimum detail or gap that can be detected by the sensor system is approximately 350 μm when using this current setup. It is also possible to render an object in 3D within a scanning angle range of 15º to 85º and identify its real height as a function of the scanning angle and the image displacement distance on the sensor. Simple and not so simple objects, such as a rubber and a plastic fork, can be rendered in 3D properly and accurately also at high resolution, using this sensor and system platform. The nip structure sensor system can detect primary and even derived colors of objects by a proper adjustment of the integration time of the system and by combining white, red, green and blue (RGB) light sources. A mean colorimetric error of 25.7 was obtained. It is also possible to detect the movement of micrometer objects using the 32 PSD sensor system. This kind of setup offers the possibility to detect if a micro object is moving, what are its dimensions and what is its position in two dimensions, even at high speeds. Results show a non-linearity of about 3% and a spatial resolution of < 2µm.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

RESUMO: Apesar de toda a evolução farmacológica e de meios complementares de diagnóstico possível nos últimos anos, o enfarte agudo do miocárdio e a morte súbita continuam a ser a primeira manifestação da aterosclerose coronária para muitos doentes, que estavam previamente assintomáticos. Os exames complementares de diagnóstico tradicionalmente usados para avaliar a presença de doença coronária, baseiam‐se na documentação de isquémia do miocárdio e por este motivo a sua positividade depende da presença de lesões coronárias obstrutivas. As lesões coronárias não obstrutivas estão também frequentemente implicadas no desenvolvimento de eventos coronários. Apesar de o risco absoluto de instabilização por placa ser superior para as lesões mais volumosas e obstrutivas, estas são menos prevalentes do que as placas não obstrutivas e assim, por questões probabilísticas, os eventos coronários resultam com frequência da rotura ou erosão destas últimas. Estudos recentes de imagiologia intracoronária avançada forneceram evidência de que apesar de ser possível identificar algumas características de vulnerabilidade em placas associadas ao desenvolvimento subsequente de eventos coronários, a sua sensibilidade e especificidade é muito baixa para aplicação clínica. Mais do que o risco associado a uma placa em particular, para o doente poderá ser mais importante o risco global da sua árvore coronária reflexo da soma das probabilidade de todas as suas lesões, sendo que quanto maior for a carga aterosclerótica maior será o seu risco. A angio TC cardíaca é a mais recente técnica de imagem não invasiva para o estudo da doença coronária e surgiu nos últimos anos fruto de importantes avanços na tecnologia de TC multidetectores. Estes avanços, permitiram uma progressiva melhoria da resolução espacial e temporal, contribuindo para a melhoria da qualidade dos exames, bem como uma significativa redução da dose de radiação. A par desta evolução tecnológica, foi aumentando a experiência e gerada mais evidência científica, tornando a angio TC cardíaca cada vez mais robusta na avaliação da doença coronária e aumentando a sua aplicabilidade clínica. Mais recentemente apareceram vários trabalhos que validaram o seu valor prognóstico, assinalando a sua chegada à idade adulta. Para além de permitir excluir a presença de doença coronária e de identificar a presença de estenoses significativas, a angio TC cardíaca permite identificar a presença de lesões coronárias não obstrutivas, característica impar desta técnica como modalidade de imagem não invasiva. Ao permitir identificar a totalidade das lesões ateroscleróticas (obstrutivas e não obstrutivas), a 18 angio TC cardíaca poderá fornecer uma quantificação da carga aterosclerótica coronária total, podendo essa identificação ser útil na estratificação dos indivíduos em risco de eventos coronários. Neste trabalho foi possível identificar preditores demográficos e clínicos de uma elevada carga aterosclerótica coronária documentada pela angioTC cardíaca, embora o seu poder discriminativo tenha sido relativamente modesto, mesmo quando agrupados em scores clínicos. Entre os vários scores, o desempenho foi um pouco melhor para o score de risco cardiovascular Heartscore. Estas limitações espelham a dificuldade de prever apenas com base em variáveis clínicas, mesmo quando agrupadas em scores, a presença e extensão da doença coronária. Um dos factores de risco clássicos, a obesidade, parece ter uma relação paradoxal com a carga aterosclerótica, o que pode justificar algumas limitações da estimativa com base em scores clínicos. A diabetes mellitus, por outro lado, foi um dos preditores clínicos mais importantes, funcionando como modelo de doença coronária mais avançada, útil para avaliar o desempenho dos diferentes índices de carga aterosclerótica. Dada a elevada prevalência de placas ateroscleróticas identificáveis por angio TC na árvore coronária, torna-‐se importante desenvolver ferramentas que permitam quantificar a carga aterosclerótica e assim identificar os indivíduos que poderão eventualmente beneficiar de medidas de prevenção mais intensivas. Com este objectivo, foi desenvolvido um índice de carga aterosclerótica que reúne a informação global acerca da localização, do grau de estenose e do tipo de placa, obtida pela angio TC cardíaca, o CT--‐LeSc. Este score poderá vir a ser uma ferramenta útil para quantificação da carga aterosclerótica coronária, sendo de esperar que possa traduzir a informação prognóstica da angio TC cardíaca. Por fim, o conceito de árvore coronária vulnerável poderá ser mais importante do que o da placa vulnerável e a sua identificação pela angio TC cardíaca poderá ser importante numa estratégia de prevenção mais avançada. Esta poderá permitir personalizar as medidas de prevenção primária, doseando melhor a sua intensidade em função da carga aterosclerótica, podendo esta vir a constituir uma das mais importantes indicações da angio TC cardíaca no futuro.---------------- ABSTRACT Despite the significant advances made possible in recent years in the field of pharmacology and diagnostic tests, acute yocardial infarction and sudden cardiac death remain the first manifestation of coronary atherosclerosis in a significant proportion of patients, as many were previously asymptomatic. Traditionally, the diagnostic exams employed for the evaluation of possible coronary artery disease are based on the documentation of myocardial ischemia and, in this way, they are linked to the presence of obstructive coronary stenosis. Nonobstructive coronary lesions are also frequently involved in the development of coronary events. Although the absolute risk of becoming unstable per plaque is higher for more obstructive and higher burden plaques, these are much less frequent than nonobstructive lesions and therefore, in terms of probability for the patient, coronary events are often the result of rupture or erosion of the latter ones. Recent advanced intracoronary imaging studies provided evidence that although it is possible to identify some features of vulnerability in plaques associated with subsequente development of coronary events, the sensitivity and sensibility are very limited for clinical application. More important than the individual risk associated with a certain plaque, for the patient it might be more important the global risk of the total coronary tree, as reflected by the sum of the diferent probabilities of all the lesions, since the higher the coronary Atherosclerotic burden, the higher the risk for the patient. Cardiac CT or Coronary CT angiography is still a young modality. It is the most recente noninvasive imaging modality in the study of coronary artery disease and its development was possible due to important advances in multidetector CT technology. These allowed significant improvements in temporal and spatial resolution, leading to better image quality and also some impressive reductions in radiation dose. At the same time, the increasing experience with this technique lead to a growing body of scientific evidence, making cardiac CT a robust imaging tool for the evaluation of coronary artery disease and increased its clinical indications. More recently, several publications documented its prognostic value, marking the transition of cardiac CT to adulthood. Besides being able to exclude the presence of coronary artery disease and of obstructive lesions, Cardiac CT allows also the identification of nonobstructive lesions, making this a unique tool in the field of noninvasive imaging modalities. By evaluating both obstructive and nonobstructive lesions, cardiac CT can provide for the quantification of total coronary atherosclerotic burden, and this can be useful to stratify the risk of future coronary events. In the present work, it was possible to identify significant demographic and clinical predictors of a high coronary atherosclerotic burden as assessed by cardiac CT, but with modest odds ratios, even when the individual variables were gathered in clinical scores. Among these diferent clinical scores, the performance was better for the Heartscore, a cardiovascular risk score. This modest performance underline the limitations on predicting the presence and severity of coronary disease based only on clinical variables, even when optimized together in risk scores, One of the classical risk factors, obesity, had in fact a paradoxical relation with coronary atherosclerotic burden and might explain some of the limitations of the clinical models. On the opposite, diabetes mellitus was one of the strongest clinical predictors, and was considered to be a model of more advanced coronary disease, useful to evaluate the performance of diferent plaque burden scores. In face of the high prevalence of plaques that can be identified in the coronary tree of patients undergoing cardiac CT, it is of utmost importance to develop tools to quantify the total coronary atherosclerotic burden providing the identification of patients that could eventually benefit from more intensive preventive measures. This was the rational for the development of a coronary atherosclerotic burden score, reflecting the comprehensive information on localization, degree of stenosis and plaque composition provided by cardiac CT – the CT-LeSc. This score may become a useful tool to quantify total coronary atherosclerotic burden and is expected to convey the strong prognostic information of cardiac CT. Lastly, the concept of vulnerable coronary tree might become more important than the concept of the vulnerable plaque and his assessment by cardiac CT Might become important in a more advance primary prevention strategy. This Could lead to a more custom-made primary prevention, tailoring the intensity of preventive measures to the atherosclerotic burden and this might become one of the most important indications of cardiac CT In the near future.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

With the recent advances in technology and miniaturization of devices such as GPS or IMU, Unmanned Aerial Vehicles became a feasible platform for a Remote Sensing applications. The use of UAVs compared to the conventional aerial platforms provides a set of advantages such as higher spatial resolution of the derived products. UAV - based imagery obtained by a user grade cameras introduces a set of problems which have to be solved, e. g. rotational or angular differences or unknown or insufficiently precise IO and EO camera parameters. In this work, UAV - based imagery of RGB and CIR type was processed using two different workflows based on PhotoScan and VisualSfM software solutions resulting in the DSM and orthophoto products. Feature detection and matching parameters influence on the result quality as well as a processing time was examined and the optimal parameter setup was presented. Products of the both workflows were compared in terms of a quality and a spatial accuracy. Both workflows were compared by presenting the processing times and quality of the results. Finally, the obtained products were used in order to demonstrate vegetation classification. Contribution of the IHS transformations was examined with respect to the classification accuracy.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

RESUMO: Este trabalho tentou contribuir para a caracterização da fisiopatologia da microcirculação coronária em diferentes formas de patologia com o auxílio da ecocardiografia transtorácica. Com a aplicação da ecocardiografia Doppler transtorácica foi efectuado o estudo da reserva coronária da artéria descendente anterior e com a ecocardiografia de contraste do miocárdio foram analisados parâmetros de perfusão do miocárdio como a velocidade da microcirculação coronária, o volume de sangue miocárdico e a reserva de fluxo miocárdico. Estas técnicas foram utilizadas em diferentes situações fisiopatológicas com particular interesse na hipertrofia ventricular esquerda de diferentes etiologias como a hipertensão arterial, estenose aórtica e cardiomiopatia hipertrófica. Também na diabetes mellitus tipo 2 e na doença coronária aterosclerótica, estudámos as alterações da microcirculação coronária. Com a mesma técnica de ecocardiografia de contraste do miocárdio foi analisada a perfusão do miocárdio num modelo experimental animal sujeito a uma dieta aterogénica. Além das conclusões específicas em relação a cada um dos trabalhos efectuados há a referir como conclusões gerais a sua fácil aplicabilidade e exequibilidade em âmbito clínico, a sua reprodutibilidade e precisão. Quando comparadas com técnicas consideradas de referência mostraram resultados com significativa correlação estatística. Em todos os doentes e nos grupos controle foi possível comprovar e quantificar o gradiente de perfusão transmural em repouso e durante a acção de stress vasodilatador, relevando a importância da perfusão sub-endocárdica na função do ventrículo esquerdo. O estudo da microcirculação coronária no grupo de doentes com hipertrofia ventricular esquerda revelou que no grupo com hipertensão arterial existe disfunção da microcirculação coronária ainda antes de se observar aumento de massa do ventrículo esquerdo, e que esta disfunção é diferente em função da geometria ventricular. Nos doentes com estenose aórtica foi demonstrado que além da disfunção da microcirculação coronária, explicada pelo fenómeno de hipertrofia, existe outro componente extrínseco que depois de corrigido através de cirurgia de substituição valvular, conduziu a uma parcial normalização dos valores de reserva coronária. Na cardiomiopatia hipertrófica observou-se uma grande heterogeneidade de perfusão transmural e foi documentado, em imagens de ecocardiografia de contraste do miocárdio e após análise paramétrica, a ausência de perfusão do miocárdio na região sub-endocárdica durante o stress vasodilatador de reserva coronária diminuídos em fases precoces de evolução da doença. Foi demonstrado que a reserva coronária na DM2 em fases mais avançadas estava significativamente diminuída. Descrevemos também em doentes com DM2 e sem doença coronária angiográfica a existência de disfunção da microcirculação coronária. Durante o stress vasodilatador, observámos e documentámos neste grupo de doentes, a existência de defeitos de perfusão transitórios ou de diminuição da velocidade da microcirculação coronária. No grupo de doentes com doença coronária confirmámos o interesse da avaliação da reserva coronária após intervenção percutânea na definição de prognóstico pós EAM, em termos de recuperação funcional do ventrículo esquerdo. Em doentes com BCRE e de difícil estratificação de risco, foi possível calcular o valor de reserva coronária e estratificar o risco de doença coronária. Num modelo experimental animal demonstrámos a exequibilidade da técnica de ECM, e verificámos que nessas condições experimentais, uma sobrecarga aterogénica na dieta, ao fim de 6 semanas, comprometia severamente a reserva coronária. Estes resultados foram parcialmente reversíveis quando à dieta foi adicionada uma estatina. Estas técnicas pela sua não invasibilidade, fácil acesso, repetibilidade e inocuidade perspectivam-se de grande utilidade na caracterização de doentes com disfunção da microcirculação coronária, nas diferentes áreas de diagnóstico, terapêutica e prevenção. A possibilidade de adaptar a técnica em modelos experimentais animais também nos parece poder vir a ter grande utilidade em investigação.----------------ABSTRACT: This work is intended to be a contribution to the study of coronary microcirculation applying new echocardiographic techniques as transthoracic Doppler echocardiography of coronary arteries and myocardial contrast echocardiography. Coronary flow reserve may be assessed by transthoracic Doppler echocardiography, and important functional microcirculation parameters as microcirculation flow velocity, myocardial blood volume and myocardial flow reserve may be evaluated through myocardial contrast echocardiography. Microcirculation was analysed in different pathophysiological settings. We addressed situations with increased left ventricular mass as systemic arterial hypertension, aortic stenosis and hypertrophic cardiomyopathy. Also coronary microcirculation was studied in type 2 Diabetes and in different clinical forms of atherosclerotic coronary artery disease. Specific and detailed conclusions were withdrawn from each experimental work. In the overall it was concluded that these two techniques were important tools to easily assess specific pathophysiological information about coronary microcirculation at bed side which would be difficult to get through other techniques. When compared with gold standard techniques, similar sensibility and specificity was found. Because of their better temporal and spatial resolution it was possible to analyse the importance of transmural perfusion gradients, both in basal and during vasodilatation, and their relation to ischemia, and mechanical wall kinetics, as wall thickening and motion. Coronary microcirculation dysfunction was found in systemic arterial hypertension early evolution stages, also related to different left ventricular geometric patterns. Different etiopathogenical explanations for aortic stenosis coronary microcirculation dysfunction were analysed and compared after aortic valve replacement. Transmural myocardial perfusion heterogeneity pattern was observed in hypertrophic cardiomyopathy which was aggravated during adenosine challenge. Coronary microcirculation dysfunction was diagnosed in type 2 diabetes both with coronary artery disease and with normal angiographic coronary arteries. Dynamic transitory subendocardial perfusion defects with adenosine vasodilatation were visualized in these patients.In patients with left branch block, transthoracic Doppler echocardiography was able to suggest a coronary reserve cut-off value for risk stratification. Also it was possible with this technique to calculate coronary flow reserve and predict restenosis after PTCA Again, in an experimental animal model, applying myocardial contrast echocardiography technique it was possible to study the consequences of an atherogenic diet and statins action on the coronary microcirculation function. Because these techniques are easily performed at bed side, are harmless, use no ionizing radiation and because of their repeatability, reproducibility and accuracythey are promissory tools to assess coronary microcirculation. Both in clinic and research areas these techniques will probably have a role in clinical diagnosis, prevention and therapeutically decision.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dissertation presented at the Faculty of Science and Technology of the New University of Lisbon in fulfillment of the requirements for the Masters degree in Electrical Engineering and Computers

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dissertation submitted in partial fulfillment of the requirements for the Degree of Master of Science in Geospatial Technologies.