11 resultados para Single-subject design
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Biomédica
Resumo:
This work is devoted to the broadband wireless transmission techniques, which are serious candidates to be implemented in future broadband wireless and cellular systems, aiming at providing high and reliable data transmission and concomitantly high mobility. In order to cope with doubly-selective channels, receiver structures based on OFDM and SC-FDE block transmission techniques, are proposed, which allow cost-effective implementations, using FFT-based signal processing. The first subject to be addressed is the impact of the number of multipath components, and the diversity order, on the asymptotic performance of OFDM and SC-FDE, in uncoded and for different channel coding schemes. The obtained results show that the number of relevant separable multipath components is a key element that influences the performance of OFDM and SC-FDE schemes. Then, the improved estimation and detection performance of OFDM-based broadcasting systems, is introduced employing SFN (Single Frequency Network) operation. An initial coarse channel is obtained with resort to low-power training sequences estimation, and an iterative receiver with joint detection and channel estimation is presented. The achieved results have shown very good performance, close to that with perfect channel estimation. The next topic is related to SFN systems, devoting special attention to time-distortion effects inherent to these networks. Typically, the SFN broadcast wireless systems employ OFDM schemes to cope with severely time-dispersive channels. However, frequency errors, due to CFO, compromises the orthogonality between subcarriers. As an alternative approach, the possibility of using SC-FDE schemes (characterized by reduced envelope fluctuations and higher robustness to carrier frequency errors) is evaluated, and a technique, employing joint CFO estimation and compensation over the severe time-distortion effects, is proposed. Finally, broadband mobile wireless systems, in which the relative motion between the transmitter and receiver induces Doppler shift which is different or each propagation path, is considered, depending on the angle of incidence of that path in relation to the direction of travel. This represents a severe impairment in wireless digital communications systems, since that multipath propagation combined with the Doppler effects, lead to drastic and unpredictable fluctuations of the envelope of the received signal, severely affecting the detection performance. The channel variations due this effect are very difficult to estimate and compensate. In this work we propose a set of SC-FDE iterative receivers implementing efficient estimation and tracking techniques. The performance results show that the proposed receivers have very good performance, even in the presence of significant Doppler spread between the different groups of multipath components.
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do Grau de Mestre em Engenharia Electrotécnica e de Computadores
Resumo:
Sustainable Construction, Materials and Practice, p. 426-432
Resumo:
RESUMO: Desenho do estudo: Estudo quantitativo, experimental prospectivo de factor único, desenho pré-teste, pós-teste. Objectivos: Determinar a efectividade da ecografia em tempo real, como Informação de Retorno Extrínseca Visual Ecográfica (IRE-VE) na performance do transverso do abdómen (TrA), em sujeitos saudáveis; analisar eventuais diferenças entre a IRE-VE e a Informação de Retorno Extrínseca Verbal Clínica (IRE-VC); medir a performance da musculatura abdominal, através das diferenças na espessura dos músculos TrA e oblíquo interno (OI) e deslizamento do TrA, em repouso e em contracção. Enquadramento: A maioria dos indivíduos não tem conhecimentos nem consciência do contributo de uma boa performance do TrA para a estabilidade da coluna lombar. Vários estudos recentes se têm dedicado a este assunto, tendo sido mostrado o importante contributo da ecografia como Informação de Retorno Extrínseca (IRE). Uma vez que o TrA e o OI contribuem para a estabilidade lombo pélvica, e que a aprendizagem do seu controlo motor é essencial para a recuperação da função, torna-se relevante clarificar o contributo da informação de retorno na primeira fase da aprendizagem da performance desses músculos, bem como encontrar as melhores estratégias para a sua realização. A ecografia foi o instrumento escolhido para servir esse objectivo. Métodos: Participaram no estudo 75 sujeitos, sem queixas lombares, com idades compreendidas entre os 18 e os 38 anos com um valor médio de 21,9 anos (±4,03), divididos aleatoriamente em três grupos com uma tarefa comum: a “Manobra do Transverso”, em que um grupo não recebeu IRE (GC), outro recebeu IRE verbal clínica e palpatória (GIRE-VC) e ooutro recebeu IRE visual ecográfica (GIRE-VE). Para efeitos de análise da contracção da musculatura abdominal, foram estudadas a espessura dos músculos TrA e OI e o deslizamento do TrA, visualizados em imagens ecográficas em tempo real, e congeladas para medição em diferido. Estes procedimentos foram apurados num estudo piloto de fidedignidade das medições em causa. Quanto à abordagem estatística das variáveis de performance muscular foi realizada uma análise da variância simples paramétrica para amostras independentes e um teste para a diferença de médias para amostras emparelhadas. Resultados: Observamos que no GC, a ausência de IRE cursou com uma performance idêntica nos dois momentos de avaliação e que nos dois grupos com IRE, das variáveis de performance, é significativamente diferente a contracção do TrA, para uma diferença de 1,95 mm no GIRE-VE (p=0,000) e de 0,84 mm no GIRE-VC (p=0,000). Ao comparar os grupos entre si houve diferenças no limiar da significância (p=0,056) para uma melhor contracção do TrA no GIRE-VE. As outras variáveis, contracção do OI e deslizamento do TrA, não revelaram efeito relacionado com a IRE em nenhum dos grupos. Conclusão: Dos resultados obtidos, podemos concluir que a IRE-VE, quando usada isoladamente, na Manobra do Transverso provoca um maior aumento na espessura do TrA, quando comparada com a IRE-VC . O uso da ecografia mostrou ser efectivo na facilitação da performance da Manobra do Transverso em sujeitos saudáveis.---------------------ABSTRACT: Study Design: Single Factor Experimental Design: Pre-Test Post-test Control Group Design. Objectives: To measure the contribution of different types of biofeedack on Transversus Abdominis (TrA) and Internal Oblique (IO) performance through changes in thickness and lateral slide of TrA anterior fascia during abdominal hollowing exercise (AHE). Background: Increasingly clinicians are using real-time ultrasound imaging as a form of supplementing feedback when teaching trunk stabilization exercises to patients; however, there has been no evidence of its effectiveness when used alone. Material and Methods: Seventy-five healthy subjects were divided randomly into 3 groups that received: group 1, no feedback; group 2, verbal and palpatory feedback, and group 3, realtime ultrasound feedback. The TrA and IO performance of each subject was twice assessed (before and after receiving feedback) when performing the AHE in a supine hook-lying position. Analysis of variance and T-test were used for the independent and paired samples, respectively, to determine significant changes in the performance of TrA and IO, based on intra and inter group analysis. Results: Group 1 had no differences between moments; group 2 had significant differences concerning TrA thickness (p=0,000) to a 0,84 mm thickness difference; group 3 had significant differences concerning TrA thickness (p=0,000) to a 1,94 mm difference; The ability to perform the AHE differed only among group 3 and group 1 (p=0.056), and only for changes in thickness of TrA muscle. No differences among groups were found neither for the lateral slide of TrA anterior fascia, nor for the internal oblique thickness. Conclusion: From the results of this study we conclude that real-time ultrasound feedback, when used alone during an AHE, can have a larger increase in TrA thickness when compared to verbal and palpatory feedback. The use of real time ultrasound showed to be effective as a feedback tool to facilitate the performance of the AHE in a supine hook-lying position in healthy subjects.
Resumo:
Dissertation submitted in partial fulfillment of the requirements for the Degree of Master of Science in Geospatial Technologies.
Resumo:
A Work Project, presented as part of the requirements for the Award of a Masters Degree in Finance from the NOVA – School of Business and Economics
Resumo:
Due to the importance and wide applications of the DNA analysis, there is a need to make genetic analysis more available and more affordable. As such, the aim of this PhD thesis is to optimize a colorimetric DNA biosensor based on gold nanoprobes developed in CEMOP by reducing its price and the needed volume of solution without compromising the device sensitivity and reliability, towards the point of care use. Firstly, the price of the biosensor was decreased by replacing the silicon photodetector by a low cost, solution processed TiO2 photodetector. To further reduce the photodetector price, a novel fabrication method was developed: a cost-effective inkjet printing technology that enabled to increase TiO2 surface area. Secondly, the DNA biosensor was optimized by means of microfluidics that offer advantages of miniaturization, much lower sample/reagents consumption, enhanced system performance and functionality by integrating different components. In the developed microfluidic platform, the optical path length was extended by detecting along the channel and the light was transmitted by optical fibres enabling to guide the light very close to the analysed solution. Microfluidic chip of high aspect ratio (~13), smooth and nearly vertical sidewalls was fabricated in PDMS using a SU-8 mould for patterning. The platform coupled to the gold nanoprobe assay enabled detection of Mycobacterium tuberculosis using 3 8l on DNA solution, i.e. 20 times less than in the previous state-of-the-art. Subsequently, the bio-microfluidic platform was optimized in terms of cost, electrical signal processing and sensitivity to colour variation, yielding 160% improvement of colorimetric AuNPs analysis. Planar microlenses were incorporated to converge light into the sample and then to the output fibre core increasing 6 times the signal-to-losses ratio. The optimized platform enabled detection of single nucleotide polymorphism related with obesity risk (FTO) using target DNA concentration below the limit of detection of the conventionally used microplate reader (i.e. 15 ng/μl) with 10 times lower solution volume (3 μl). The combination of the unique optical properties of gold nanoprobes with microfluidic platform resulted in sensitive and accurate sensor for single nucleotide polymorphism detection operating using small volumes of solutions and without the need for substrate functionalization or sophisticated instrumentation. Simultaneously, to enable on chip reagents mixing, a PDMS micromixer was developed and optimized for the highest efficiency, low pressure drop and short mixing length. The optimized device shows 80% of mixing efficiency at Re = 0.1 in 2.5 mm long mixer with the pressure drop of 6 Pa, satisfying requirements for the application in the microfluidic platform for DNA analysis.
Resumo:
The present work has its origin on the necessity of enabling a design certified company, or DOA (Design Organization Approval), to perform a modification; this modification is the installation of EO/IR (Electro-optical infrared) sensors on aircrafts. The subject of interest in this dissertation lies on the aerodynamic impact of the modification on the aircraft. The primary purpose of the present thesis is the creation of a methodology that regards the design stage of the modification. This methodology serves as guidance to the DOA design team that is assigned to the design of the modification. The methodology includes a recommendation to the certification of the modification; it contains a method intended to decide the location of the installation of the sensors on the aircraft; it also comprises of a design structure specifically adapted to the modification in study. Regarding the aerodynamic impact, it is studied the aerodynamic analysis’ tools, which allows one to relate the different stages of design to the most suited tools to each stage. A case study is performed with the purpose of not only validating the methodology which was created but also to giving a first approach to the preliminary design of the modification. As example, there are used the Lockheed Martin C-130 aircraft and the FLIR Star Safire III sensor.
Resumo:
Existing wireless networks are characterized by a fixed spectrum assignment policy. However, the scarcity of available spectrum and its inefficient usage demands for a new communication paradigm to exploit the existing spectrum opportunistically. Future Cognitive Radio (CR) devices should be able to sense unoccupied spectrum and will allow the deployment of real opportunistic networks. Still, traditional Physical (PHY) and Medium Access Control (MAC) protocols are not suitable for this new type of networks because they are optimized to operate over fixed assigned frequency bands. Therefore, novel PHY-MAC cross-layer protocols should be developed to cope with the specific features of opportunistic networks. This thesis is mainly focused on the design and evaluation of MAC protocols for Decentralized Cognitive Radio Networks (DCRNs). It starts with a characterization of the spectrum sensing framework based on the Energy-Based Sensing (EBS) technique considering multiple scenarios. Then, guided by the sensing results obtained by the aforementioned technique, we present two novel decentralized CR MAC schemes: the first one designed to operate in single-channel scenarios and the second one to be used in multichannel scenarios. Analytical models for the network goodput, packet service time and individual transmission probability are derived and used to compute the performance of both protocols. Simulation results assess the accuracy of the analytical models as well as the benefits of the proposed CR MAC schemes.
Resumo:
Ionic Liquids (ILs) consist in organic salts that are liquid at/or near room temperature. Since ILs are entirely composed of ions, the formation of ion pairs is expected to be one essential feature for describing solvation in ILs. In recent years, protein - ionic liquid (P-IL) interactions have been the subject of intensive studies mainly because of their capability to promote folding/unfolding of proteins. However, the ion pairs and their lifetimes in ILs in P-IL thematic is dismissed, since the action of ILs is therefore the result of a subtle equilibrium between anion-cation interaction, ion-solvent and ion-protein interaction. The work developed in this thesis innovates in this thematic, once the design of ILs for protein stabilisation was bio-inspired in the high concentration of organic charged metabolites found in cell milieu. Although this perception is overlooked, those combined concentrations have been estimated to be ~300 mM among the macromolecules at concentrations exceeding 300 g/L (macromolecular crowding) and transient ion-pair can naturally occur with a potential specific biological role. Hence the main objective of this work is to develop new bio-ILs with a detectable ion-pair and understand its effects on protein structure and stability, under crowding environment, using advanced NMR techniques and calorimetric techniques. The choline-glutamate ([Ch][Glu]) IL was synthesized and characterized. The ion-pair was detected in water solutions using mainly the selective NOE NMR technique. Through the same technique, it was possible to detect a similar ion-pair promotion under synthetic and natural crowding environments. Using NMR spectroscopy (protein diffusion, HSQC experiments, and hydrogen-deuterium exchange) and differential scanning calorimetry (DSC), the model protein GB1 (production and purification in isotopic enrichment media) it was studied in the presence of [Ch][Glu] under macromolecular crowding conditions (PEG, BSA, lysozyme). Under dilute condition, it is possible to assert that the [Ch][Glu] induces a preferential hydration by weak and non-specific interactions, which leads to a significant stabilisation. On the other hand, under crowding environment, the [Ch][Glu] ion pair is promoted, destabilising the protein by favourable weak hydrophobic interactions , which disrupt the hydration layer of the protein. However, this capability can mitigates the effect of protein crowders. Overall, this work explored the ion-pair existence and its consequences on proteins in conditions similar to cell milieu. In this way, the charged metabolites found in cell can be understood as key for protein stabilisation.