9 resultados para Piezoelectric transducers
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Química e Bioquímica
Resumo:
Dissertation presented to obtain the PhD degree in Electrical and Computer Engineering - Electronics
Resumo:
In this thesis a piezoelectric energy harvesting system, responsible for regulating the power output of a piezoelectric transducer subjected to ambient vibration, is designed to power an RF receiver with a 6 mW power consump-tion. The electrical characterisation of the chosen piezoelectric transducer is the starting point of the design, which subsequently presents a full-bridge cross-coupled rectifier that rectifies the AC output of the transducer and a low-dropout regulator responsible for delivering a constant voltage system output of 0.6 V, with low voltage ripple, which represents the receiver’s required sup-ply voltage. The circuit is designed using CMOS 130 nm UMC technology, and the system presents an inductorless architecture, with reduced area and cost. The electrical simulations run for the complete circuit lead to the conclusion that the proposed piezoelectric energy harvesting system is a plausible solution to power the RF receiver, provided that the chosen transducer is subjected to moderate levels of vibration.
Resumo:
RESUMO: Os Staphylococcus aureus resistentes à meticilina (MRSA, do inglês “methicillin-resistant Staphylococcus aureus”) são um dos principais agentes responsáveis por infeções hospitalares. Os MRSA são resistentes a praticamente todos os antibióticos β-lactâmicos devido a dois mecanismos principais: produção de β-lactamase (bla), codificada pelo gene blaZ, e produção de uma proteína de ligação à penicilina (PBP2a, do inglês “penicillin binding protein 2”), codificada pelo gene mecA. Estes dois genes são regulados por sistemas homólogos, constituídos por um sensor-transdutor (BlaR1 e MecR1) e um repressor (BlaI e MecI), de tal modo que ambos os sistemas são capazes de co-regular os genes mecA e blaZ, embora com eficiências de indução muito diferentes. De facto, a indução mediada pelo sistema mecI-mecR1 é tão lenta que se acredita que este sistema não está funcional na maioria das estirpes MRSA. No entanto, dados recentes do nosso laboratório, demonstram a ausência de relação entre a presença do gene mecI e o nível de resistência à meticilina em estirpes MRSA epidémicas, e também que, o fenótipo de resistência da grande maioria das estirpes não é perturbado pela sobre-expressão em trans do repressor mecI. Curiosamente, as duas estirpes em que a expressão da resistência foi afetada pela sobre-expressão do mecI são negativas para o locus da β-lactamase, o que sugere que este locus pode interferir diretamente com a repressão do gene mecA mediada pelo MecI. Nesta tese de mestrado esta hipótese foi explorada usando estratégias de biologia molecular e ensaios fenotípicos da resistência aos -lactâmicos. Os resultados obtidos demonstram que a presença do plasmídeo nativo da β-lactamase não só anula a repressão mediada pelo MecI, como também aumenta o nível de resistência das estirpes parentais. Várias hipóteses foram então formuladas para explicar estas observações. Dados preliminares, em conjunto com evidências experimentais publicadas, sugerem que o BlaI forma hetero-dímeros com o MecI que, após a indução, são inativados eficientemente pelo BlaR1. Em conclusão, estes resultados apresentam novas perspetivas para o mecanismo de regulação do mecA e para uma nova importante função do operão da β-lactamase para o fenótipo das estirpes MRSA.-------------------ABSTRACT: Methicillin-resistant Staphylococcus aureus (MRSA) is an important nosocomial pathogen and is also emerging in the community. MRSA is cross-resistant to virtually all β-lactam antibiotics and has acquired two main resistance mechanisms: production of β-lactamase (bla), coded by blaZ, and production of penicillin binding protein 2a (PBP2a), coded by mecA. Both genes are regulated by homologous sensor-transducers (BlaR1 and MecR1) and repressors (BlaI and MecI), and coregulation of mecA and blaZ by both systems has been demonstrated, although with remarkable different efficiencies. In fact, induction of mecA by mecI-mecR1 is so slow that it is believed it is not functional in most MRSA strains. However, recent data from our laboratory has unexpectedly demonstrated that not only there is no correlation between the presence of mecI gene and the resistance level in epidemic MRSA strains, but also that for most strains there were no significant changes on the resistance phenotype upon the mecI overexpression in trans. Interestingly, the two strains in which mecI overexpression affected the resistance expression were negative for the bla locus, suggesting that this locus may interfere directly with the MecI-mediated repression of mecA and account for those puzzling observations. In this master thesis we have explored this hypothesis using molecular biology strategies and phenotypic analysis of -lactam resistance. The data obtained demonstrate that the presence of a wild-type plasmid containing the bla locus not only disrupts the MecImediated repression, but also significantly enhances the expression of resistance. Several preliminary hypotheses were formulated to explain these observations and preliminary data, together with published evidence, support the working model that BlaI forms functional hetero-dimers with MecI, which upon induction are readily inactivated by BlaR1. These results provide new insights into the regulatory mechanism(s) of mecA and open new perspectives for the role of β-lactamase operon in the MRSA phenotype.
Resumo:
Sensors 2010, 10, 11530-11555
Resumo:
Nowadays it is known that the human body is continuous source of many types of energy and the devices used for collecting energy taken from the environment also have the required capabilities for the collection of the energy produced by the Human body (HB), but very limited and with very low efficiency. Low power and high yield converters are particularly needed in these cases of collecting energy from human activity and its movements due to the small amount of energy generated this way. But this situation can be improved. Enhancing or focusing the human movements by using mechanical amplifiers applied to the piezoelectric element. By doing so the input of energy in the element increases. As such increasing its output, therefore producing more energy.
Resumo:
Since the invention of photography humans have been using images to capture, store and analyse the act that they are interested in. With the developments in this field, assisted by better computers, it is possible to use image processing technology as an accurate method of analysis and measurement. Image processing's principal qualities are flexibility, adaptability and the ability to easily and quickly process a large amount of information. Successful examples of applications can be seen in several areas of human life, such as biomedical, industry, surveillance, military and mapping. This is so true that there are several Nobel prizes related to imaging. The accurate measurement of deformations, displacements, strain fields and surface defects are challenging in many material tests in Civil Engineering because traditionally these measurements require complex and expensive equipment, plus time consuming calibration. Image processing can be an inexpensive and effective tool for load displacement measurements. Using an adequate image acquisition system and taking advantage of the computation power of modern computers it is possible to accurately measure very small displacements with high precision. On the market there are already several commercial software packages. However they are commercialized at high cost. In this work block-matching algorithms will be used in order to compare the results from image processing with the data obtained with physical transducers during laboratory load tests. In order to test the proposed solutions several load tests were carried out in partnership with researchers from the Civil Engineering Department at Universidade Nova de Lisboa (UNL).
Resumo:
In this thesis a CMOS low-power and low-voltage RF receiver front-end is presented. The main objective is to design this RF receiver so that it can be powered by a piezoelectric energy harvesting power source, included in a Wireless Sensor Node application. For this type of applications the major requirements are: the low-power and low-voltage operation, the reduced area and cost and the simplicity of the architecture. The system key blocks are the LNA and the mixer, which are studied and optimized with greater detail, achieving a good linearity, a wideband operation and a reduced introduction of noise. A wideband balun LNA with noise and distortion cancelling is designed to work at a 0.6 V supply voltage, in conjunction with a double-balanced passive mixer and subsequent TIA block. The passive mixer operates in current mode, allowing a minimal introduction of voltage noise and a good linearity. The receiver analog front-end has a total voltage conversion gain of 31.5 dB, a 0.1 - 4.3 GHz bandwidth, an IIP3 value of -1.35 dBm, and a noise figure lower than 9 dB. The total power consumption is 1.9 mW and the die area is 305x134.5 m2, using a standard 130 nm CMOS technology.
Resumo:
Analytical, numerical and experimental models have been developed over time to try to characterize and understand the metal cutting process by chip removal. A true knowledge of the cutting process by chip removal is required by the increasing production, by the quality requirements of the product and by the reduced production time, in the industries in which it is employed. In this thesis an experimental setup is developed to evaluate the forces and the temperature distribution in the tool according to the orthogonal cutting model conditions, in order to evaluate its performance and its possible adoption in future works. The experimental setup is developed in a CNC lathe and uses an orthogonal cutting configuration, in which thin discs fixed onto a mandrel are cut by the cutting insert. In this experimental setup, the forces are measured by a piezoelectric dynamometer while temperatures are measured by thermocouples placed juxtaposed to the side face of the cutting insert. Three different solutions are implemented and evaluated for the thermocouples attachment in the cutting insert: thermocouples embedded in thermal paste, thermocouples embedded in copper plate and thermocouples brazed in the cutting insert. From the tests performed in the experimental setup it is concluded that the adopted forces measurement technique shows a good performance. Regarding to the adopted temperatures measurement techniques, only the thermocouples brazed in the cutting insert solution shows a good performance for temperature measurement. The remaining solutions show contact problems between the thermocouple and the side face of the cutting insert, especially when the vibration phenomenon intensifies during the cut. It is concluded that the experimental setup does not present a sufficiently robust and reliable performance, and that it can only be used in future work after making improvements in the assembly of the thermocouples.