8 resultados para Pancreatitis Diagnosis
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Engenharia Electrotécnica e Computadores
Resumo:
Thesis for the Master degree in Structural and Functional Biochemistry
Resumo:
Dissertação para obtenção do Grau de Doutor em Engenharia Electrotécnica e Computadores especialidade: Robótica e Manufactura Integrada
Resumo:
This dissertation is presented to obtain a Master degree in Structural and Functional Biochemistry
Resumo:
ABSTRACT:C-reactive protein (CRP) has been widely used in the early risk assessment of patients with acute pancreatitis (AP), but unclear aspects about its prognostic accuracy in this setting persist. This project evaluated first CRP prognostic accuracy for severity, pancreatic necrosis (PNec), and in-hospital mortality (IM) in AP in terms of the best timing for CRP measurement and the optimal CRP cutoff points. Secondly it was evaluated the CRP measured at approximately 24 hours after hospital admission (CRP24) prognostic accuracy for IM in AP individually and in a combined model with a recent developed tool for the early risk assessment of patients with AP, the Bedside Index for Severity in AP (BISAP). Two single-centre retrospective cohort studies were held. The first study included 379 patients and the second study included 134 patients. Statistical methods such as the Hosmer-Lemeshow goodness-of-fit test, the area under the receiver-operating characteristic curve, the net reclassification improvement, and the integrated discrimination improvement were used. It was found that CRP measured at approximately 48 hours after hospital admission (CRP48) had a prognostic accuracy for severity, PNec, and IM in AP better than CRP measured at any other timing. It was observed that the optimal CRP48 cutoff points for severity, PNec, and IM in AP varied from 170mg/l to 190mg/l, values greater than the one most often recommended in the literature – 150mg/l. It was found that CRP24 had a good prognostic accuracy for IM in AP and that the cutoff point of 60mg/l had a negative predictive value of 100%. Finally it was observed that the prognostic accuracy of a combined model including BISAP and CRP24 for IM in AP could perform better than the BISAP alone model. These results might have a direct impact on the early risk assessment of patients with AP in the daily clinical practice.--------- RESUMO: A proteina c-reactiva (CRP) tem sido largamente usada na avaliação precoce do risco em doentes com pancreatite aguda (AP), mas aspectos duvidosos acerca do seu valor prognóstico neste contexto persistem. Este projecto avaliou primeiro o valor prognóstico da CRP para a gravidade, a necrose pancreática (PNec) e a mortalidade intra-hospitalar (IM) na AP em termos do melhor momento para efectuar a sua medição e dos seus pontos-de-corte óptimos. Em segundo lugar foi avaliado o valor prognóstico da proteína c-reactiva medida aproximadamente às 24 horas após a admissão hospitalar (CRP24) para a IM na AP isoladamente e num modelo combinado, que incluiu uma ferramenta de avaliação precoce do risco em doentes com AP recentemente desenvolvida, o Bedside Index for Severity in Acute Pancreatitis (BISAP). Dois estudos unicêntricos de coorte retrospectivo foram realizados. O primeiro estudo incluiu 379 doentes e o segundo estudo incluiu 134 doentes. Metodologias estatísticas como o teste de Hosmer-Lemeshow goodness-of-fit, a area under the receiver-operating characteristic curve, o net reclassification improvement e o integrated discrimination improvement foram usadas. Verificou-se que a CRP medida às 48 horas após a admissão hospitalar (CRP48) teve um valor prognóstico para a gravidade, a PNec e a IM na AP melhor do que a CRP medida em qualquer outro momento. Observou-se que os pontos de corte óptimos da CRP48 para a gravidade, a PNec e a IM na AP variaram entre 170mg/l e 190mg/l, valores acima do valor mais frequentemente recomendado na literatura – 150mg/l. Verificou-se que a CRP medida aproximadamente às 24 horas após a admissão hospitalar (CRP24) teve um bom valor prognóstico para a IM na AP e que o ponto de corte 60mg/l teve um valor preditivo negativo de 100%. Finalmente observou-se que o valor prognóstico de um modelo combinado incluindo o BISAP e a CRP24 para a IM na AP pode ter um desempenho melhor do que o do BISAP isoladamente. Estes resultados podem ter um impacto directo na avaliação precoce do risco em doentes com AP na prática clínica diária.
Resumo:
Breast cancer is the most common type of cancer among women all over the world. An important issue that is not commonly addressed in breast cancer imaging literature is the importance of imaging the underarm region—where up to 80% of breast cancer cells can metastasise to. The first axillary lymph nodes to receive drainage from the primary tumour in the breast are called Sentinel Node. If cancer cells are found in the Sentinel Node, there is an increased risk of metastatic breast cancer which makes this evaluation crucial to decide what follow-up exams and therapy to follow. However, non-invasive detection of cancer cells in the lymph nodes is often inconclusive, leading to the surgical removal of too many nodes which causes adverse side-effects for patients. Microwave Imaging is one of the most promising non-invasive imaging modalities for breast cancer early screening and monitoring. This novel study tests the feasibility of imaging the axilla region by means of the simulation of an Ultra-Wideband Microwave Imaging system. Simulations of such system are completed in several 2D underarm models that mimic the axilla. Initial imaging results are obtained by means of processing the simulated backscattered signals by eliminating artefacts caused by the skin and beamforming the processed signals in order to time-align all the signals recorded at each antenna. In this dissertation several image formation algorithms are implemented and compared by visual inspection of the resulting images and through a range of performance metrics, such as Signal-to-Clutter Ratio and FullWidth Half Maximum calculations. The results in this study showed that Microwave Imaging is a promising technique that might allow to identify the presence and location of metastasised cancer cells in axillary lymph nodes, enabling the non-invasive evaluation of breast cancer staging.
Resumo:
Towards a holistic perspective of CRM, this project aims to diagnose and propose a strategy and market segmentation for Siemens Healthcare. The main underlying principle is to apply a full customer-centric outlook taking own business properties into consideration while preserving Siemens Healthcare’s culture and vision. Mainly focused on market segmentation, this project goes beyond established boundaries by employing an unbiased perspective of CRM while challenging current strategy, goals, processes, tools, initiatives and KPIs. In order to promote a sustainable business excellence strategy, this project aspires to streamline CRM strategic importance and driving the company one step forward.
Resumo:
Nowadays, many of the manufactory and industrial system has a diagnosis system on top of it, responsible for ensuring the lifetime of the system itself. It achieves this by performing both diagnosis and error recovery procedures in real production time, on each of the individual parts of the system. There are many paradigms currently being used for diagnosis. However, they still fail to answer all the requirements imposed by the enterprises making it necessary for a different approach to take place. This happens mostly on the error recovery paradigms since the great diversity that is nowadays present in the industrial environment makes it highly unlikely for every single error to be fixed under a real time, no production stop, perspective. This work proposes a still relatively unknown paradigm to manufactory. The Artificial Immune Systems (AIS), which relies on bio-inspired algorithms, comes as a valid alternative to the ones currently being used. The proposed work is a multi-agent architecture that establishes the Artificial Immune Systems, based on bio-inspired algorithms. The main goal of this architecture is to solve for a resolution to the error currently detected by the system. The proposed architecture was tested using two different simulation environment, each meant to prove different points of views, using different tests. These tests will determine if, as the research suggests, this paradigm is a promising alternative for the industrial environment. It will also define what should be done to improve the current architecture and if it should be applied in a decentralised system.