35 resultados para Measuring method


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The Stiles-Crawford effect (SCE) is the well-known phenomenon in which the brightness of light perceived by the human eye depends upon its entrance point in the pupil. This physiological characteristic is due to the directional sensitivity of the cone photoreceptors in the retina and it displays an approximately Gaussian dependency which is altered in a number of pathologies. Retinal imaging, a widely spread clinical practice, may be used to evaluate the SCE and thus serve as diagnostic tool. Nonetheless, its use for such a purpose is still underdeveloped and far from the clinical reality. In this project a fundus camera was built and used to assess the cone photoreceptor directionality by reflective imaging of the retina in healthy individuals. The physical and physiological implications of its development are addressed in detail in the text: the optical properties of the human eye, illumination issues, acquiring a retinal image formed by the eye, among others. A full description of the developmental process that led to the final measuring method and results is also given. The developed setup was successfully used to obtain high quality images of the eye fundus and in particular the parafoveal cone photoreceptors. The SCE was successfully observed and characterized. Even though considerable improvements could be done to the measurement method, the project showed the feasibility of using retinal imaging to evaluate the SCE thus motivating its usage in a clinical environment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia Electrotécnica e de Computadores

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para a obtenção do grau de Mestre em Engenharia do Ambiente,perfil Sanitária

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Void formation during the injection phase of the liquid composite molding process can be explained as a consequence of the non-uniformity of the flow front progression. This is due to the dual porosity within the fiber perform (spacing between the fiber tows is much larger than between the fibers within in a tow) and therefore the best explanation can be provided by a mesolevel analysis, where the characteristic dimension is given by the fiber tow diameter of the order of millimeters. In mesolevel analysis, liquid impregnation along two different scales; inside fiber tows and within the open spaces between the fiber tows must be considered and the coupling between the flow regimes must be addressed. In such cases, it is extremely important to account correctly for the surface tension effects, which can be modeled as capillary pressure applied at the flow front. Numerical implementation of such boundary conditions leads to illposing of the problem, in terms of the weak classical as well as stabilized formulation. As a consequence, there is an error in mass conservation accumulated especially along the free flow front. A numerical procedure was formulated and is implemented in an existing Free Boundary Program to reduce this error significantly.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sustainable Construction, Materials and Practice, p. 426-432

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RESUMO - A exposição a formaldeído é reconhecidamente um dos mais importantes factores de risco presente nos laboratórios hospitalares de anatomia patológica. Neste contexto ocupacional, o formaldeído é utilizado em solução, designada comummente por formol. Trata-se de uma solução comercial de formaldeído, normalmente diluída a 10%, sendo pouco onerosa e, por esse motivo, a eleita para os trabalhos de rotina em anatomia patológica. A solução é utilizada como fixador e conservante do material biológico, pelo que as peças anatómicas a serem processadas são previamente impregnadas. No que concerne aos efeitos para a saúde do formaldeído, os efeitos locais parecem apresentar um papel mais importante comparativamente com os efeitos sistémicos, devido à sua reactividade e rápido metabolismo nas células da pele, tracto gastrointestinal e pulmões. Da mesma forma, a localização das lesões correspondem principalmente às zonas expostas às doses mais elevadas deste agente químico, ou seja, o desenvolvimento dos efeitos tóxicos dependerá mais da intensidade da dose externa do que da duração da exposição. O efeito do formaldeído no organismo humano mais facilmente detectável é a acção irritante, transitória e reversível sobre as mucosas dos olhos e aparelho respiratório superior (naso e orofaringe), o que acontece em geral para exposições frequentes e superiores a 1 ppm. Doses elevadas são citotóxicas e podem conduzir a degenerescência e necrose das mucosas e epitélios. No que concerne aos efeitos cancerígenos, a primeira avaliação efectuada pela International Agency for Research on Cancer data de 1981, actualizada em 1982, 1987, 1995 e 2004, considerando-o como um agente cancerígeno do grupo 2A (provavelmente carcinogénico). No entanto, a mais recente avaliação, em 2006, considera o formaldeído no Grupo 1 (agente carcinogénico) com base na evidência de que a exposição a este agente é susceptível de causar cancro nasofaríngeo em humanos. Constituiu objectivo principal deste estudo caracterizar a exposição profissional a formaldeído nos laboratórios hospitalares de anatomia patológica Portugueses. Pretendeu-se, ainda, descrever os fenómenos ambientais da contaminação ambiental por formaldeído e explorar eventuais associações entre variáveis. Considerou-se uma amostra de 10 laboratórios hospitalares de anatomia patológica, avaliada a exposição dos três grupos profissionais por comparação com os dois referenciais de exposição e, ainda, conhecidos os valores de concentração máxima em 83 actividades. Foram aplicados simultaneamente dois métodos distintos de avaliação ambiental: um dos métodos (Método 1) fez uso de um equipamento de leitura directa com o princípio de medição por Photo Ionization Detection, com uma lâmpada de 11,7 eV e, simultaneamente, realizou-se o registo da actividade. Este método disponibilizou dados para o referencial de exposição da concentração máxima; o outro método (Método 2) traduziu-se na aplicação do método NIOSH 2541, implicando o uso de bombas de amostragem eléctricas de baixo caudal e posterior processamento analítico das amostras por cromatografia gasosa. Este método, por sua vez, facultou dados para o referencial de exposição da concentração média ponderada. As estratégias de medição de cada um dos métodos e a definição dos grupos de exposição existentes neste contexto ocupacional, designadamente os Técnicos de Anatomia Patológica, os Médicos Anatomo-Patologistas e os Auxiliares, foram possíveis através da informação disponibilizada pelas técnicas de observação da actividade da análise (ergonómica) do trabalho. Estudaram-se diversas variáveis independentes, nomeadamente a temperatura ambiente e a humidade relativa, a solução de formaldeído utilizada, as condições de ventilação existentes e o número médio de peças processadas por dia em cada laboratório. Para a recolha de informação sobre estas variáveis foi preenchida, durante a permanência nos laboratórios estudados, uma Grelha de Observação e Registo. Como variáveis dependentes seleccionaram-se três indicadores de contaminação ambiental, designadamente o valor médio das concentrações superiores a 0,3 ppm em cada laboratório, a Concentração Média Ponderada obtida para cada grupo de exposição e o Índice do Tempo de Regeneração de cada laboratório. Os indicadores foram calculados e definidos através dos dados obtidos pelos dois métodos de avaliação ambiental aplicados. Baseada no delineado pela Universidade de Queensland, foi ainda aplicada uma metodologia de avaliação do risco de cancro nasofaríngeo nas 83 actividades estudadas de modo a definir níveis semi-quantitativos de estimação do risco. Para o nível de Gravidade considerou-se a informação disponível em literatura científica que define eventos biológicos adversos, relacionados com o modo de acção do agente químico e os associa com concentrações ambientais de formaldeído. Para o nível da Probabilidade utilizou-se a informação disponibilizada pela análise (ergonómica) de trabalho que permitiu conhecer a frequência de realização de cada uma das actividades estudadas. A aplicação simultânea dos dois métodos de avaliação ambiental resultou na obtenção de resultados distintos, mas não contraditórios, no que concerne à avaliação da exposição profissional a formaldeído. Para as actividades estudadas (n=83) verificou-se que cerca de 93% dos valores são superiores ao valor limite de exposição definido para a concentração máxima (VLE-CM=0,3 ppm). O “exame macroscópico” foi a actividade mais estudada e onde se verificou a maior prevalência de resultados superiores ao valor limite (92,8%). O valor médio mais elevado da concentração máxima (2,04 ppm) verificou-se no grupo de exposição dos Técnicos de Anatomia Patológica. No entanto, a maior amplitude de resultados observou-se no grupo dos Médicos Anatomo-Patologistas (0,21 ppm a 5,02 ppm). No que respeita ao referencial da Concentração Média Ponderada, todos os valores obtidos nos 10 laboratórios estudados para os três grupos de exposição foram inferiores ao valor limite de exposição definido pela Occupational Safety and Health Administration (TLV-TWA=0,75 ppm). Verificou-se associação estatisticamente significativa entre o número médio de peças processadas por laboratório e dois dos três indicadores de contaminação ambiental utilizados, designadamente o valor médio das concentrações superiores a 0,3 ppm (p=0,009) e o Índice do Tempo de Regeneração (p=0,001). Relativamente à temperatura ambiente não se observou associação estatisticamente significativa com nenhum dos indicadores de contaminação ambiental utilizados. A humidade relativa apresentou uma associação estatisticamente significativa apenas com o indicador de contaminação ambiental da Concentração Média Ponderada de dois grupos de exposição, nomeadamente com os Médicos Anatomo-Patologistas (p=0,02) e os Técnicos de Anatomia Patológica (p=0,04). A aplicação da metodologia de avaliação do risco nas 83 actividades estudadas permitiu verificar que, em cerca de dois terços (35%), o risco foi classificado como (pelo menos) elevado e, ainda, constatar que 70% dos laboratórios apresentou pelo menos 1 actividade com a classificação de risco elevado. Da aplicação dos dois métodos de avaliação ambiental e das informações obtidas para os dois referenciais de exposição pode concluir-se que o referencial mais adequado é a Concentração Máxima por estar associado ao modo de actuação do agente químico. Acresce, ainda, que um método de avaliação ambiental, como o Método 1, que permite o estudo das concentrações de formaldeído e simultaneamente a realização do registo da actividade, disponibiliza informações pertinentes para a intervenção preventiva da exposição por permitir identificar as actividades com a exposição mais elevada, bem como as variáveis que a condicionam. As peças anatómicas apresentaram-se como a principal fonte de contaminação ambiental por formaldeído neste contexto ocupacional. Aspecto de particular interesse, na medida que a actividade desenvolvida neste contexto ocupacional e, em particular na sala de entradas, é centrada no processamento das peças anatómicas. Dado não se perspectivar a curto prazo a eliminação do formaldeído, devido ao grande número de actividades que envolvem ainda a utilização da sua solução comercial (formol), pode concluir-se que a exposição a este agente neste contexto ocupacional específico é preocupante, carecendo de uma intervenção rápida com o objectivo de minimizar a exposição e prevenir os potenciais efeitos para a saúde dos trabalhadores expostos. ---------------- ABSTRACT - Exposure to formaldehyde is recognized as one of the most important risk factors present in anatomy and pathology laboratories from hospital settings. In this occupational setting, formaldehyde is used in solution, typically diluted to 10%, and is an inexpensive product. Because of that, is used in routine work in anatomy and pathology laboratories. The solution is applied as a fixative and preservative of biological material. Regarding formaldehyde health effects, local effects appear to have a more important role compared with systemic effects, due to his reactivity and rapid metabolism in skin, gastrointestinal tract and lungs cells. Likewise, lesions location correspond mainly to areas exposed to higher doses and toxic effects development depend more on external dose intensity than exposure duration. Human body formaldehyde effect more easily detectable is the irritating action, transient and reversible on eyes and upper respiratory tract (nasal and throat) membranes, which happen in general for frequent exposure to concentrations higher than 1 ppm. High doses are cytotoxic and can lead to degeneration, and also to mucous membranes and epithelia necrosis. With regard to carcinogenic effects, first assessment performed by International Agency for Research on Cancer in 1981, updated in 1982, 1987, 1995 and 2004, classified formaldehyde in Group 2A (probably carcinogenic). However, most recent evaluation in 2006, classifies formaldehyde carcinogenic (Group 1), based on evidence that exposure to this agent is likely to cause nasopharyngeal cancer in humans. This study principal objective was to characterize occupational exposure to formaldehyde in anatomy and pathology hospital laboratories, as well to describe formaldehyde environmental contamination phenomena and explore possible associations between variables. It was considered a sample of 10 hospital pathology laboratories, assessed exposure of three professional groups for comparison with two exposure metrics, and also knows ceiling concentrations in 83 activities. Were applied, simultaneously, two different environmental assessment methods: one method (Method 1) using direct reading equipment that perform measure by Photo Ionization Detection, with 11,7 eV lamps and, simultaneously, make activity description and film. This method provided data for ceiling concentrations for each activity study (TLV-C). In the other applied method (Method 2), air sampling and formaldehyde analysis were performed according to NIOSH method (2541). This method provided data average exposure concentration (TLV-TWA). Measuring and sampling strategies of each methods and exposure groups definition (Technicians, Pathologists and Assistants) was possible by information provided by activities (ergonomic) analysis. Several independent variables were studied, including temperature and relative humidity, formaldehyde solution used, ventilation conditions, and also anatomic pieces mean value processed per day in each laboratory. To register information about these variables was completed an Observation and Registration Grid. Three environmental contamination indicators were selected has dependent variables namely: mean value from concentrations exceeding 0,3 ppm in each laboratory, weighted average concentration obtained for each exposure group, as well each laboratory Time Regeneration Index. These indicators were calculated and determined through data obtained by the two environmental assessment methods. Based on Queensland University proposal, was also applied a methodology for assessing nasopharyngeal cancer risk in 83 activities studied in order to obtain risk levels (semi-quantitative estimation). For Severity level was considered available information in scientific literature that defines biological adverse events related to the chemical agent action mode, and associated with environment formaldehyde concentrations. For Probability level was used information provided by (ergonomic) work analysis that helped identifies activity frequency. Environmental assessment methods provide different results, but not contradictory, regarding formaldehyde occupational exposure evaluation. In the studied activities (n=83), about 93% of the values were above exposure limit value set for ceiling concentration in Portugal (VLE-CM = 0,3 ppm). "Macroscopic exam" was the most studied activity, and obtained the higher prevalence of results superior than 0,3 ppm (92,8%). The highest ceiling concentration mean value (2,04 ppm) was obtain in Technicians exposure group, but a result wider range was observed in Pathologists group (0,21 ppm to 5,02 ppm). Concerning Method 2, results from the three exposure groups, were all lower than limit value set by Occupational Safety and Health Administration (TLV-TWA=0,75ppm). There was a statistically significant association between anatomic pieces mean value processed by each laboratory per day, and two of the three environmental contamination indicators used, namely average concentrations exceeding 0,3 ppm (p=0,009) and Time Regeneration Index (p=0,001). Temperature was not statistically associated with any environmental contamination used indicators. Relative humidity had a statistically significant association only with one environmental contamination indicator, namely weighted average concentration, particularly with Pathologists group (p=0,02) and Technicians group (p=0,04). Risk assessment performed in the 83 studied activities showed that around two thirds (35%) were classified as (at least) high, and also noted that 70% of laboratories had at least 1 activity with high risk rating. The two environmental assessment methods application, as well information obtained from two exposure metrics, allowed to conclude that most appropriate exposure metric is ceiling concentration, because is associated with formaldehyde action mode. Moreover, an environmental method, like Method 1, which allows study formaldehyde concentrations and relates them with activity, provides relevant information for preventive information, since identifies the activity with higher exposure, as well variables that promote exposure. Anatomic pieces represent formaldehyde contamination main source in this occupational setting, and this is of particular interest because all activities are focused on anatomic pieces processing. Since there is no prospect, in short term, for formaldehyde use elimination due to large number of activities that still involve solution use, it can be concluded that exposure to this agent, in this particular occupational setting, is preoccupant, requiring an rapid intervention in order to minimize exposure and prevent potential health effects in exposed workers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hindawi Publishing Corporation Bioinorganic Chemistry and Applications Volume 2010, Article ID 634597, 8 pages

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertation submitted in partial fulfillment of the requirements for the Degree of Master of Science in Geospatial Technologies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RESUMO: Um dos principais resultados das intervenções de Fisioterapia dirigidas a utentes com Dor Lombar Crónica (DLC) é reduzir a incapacidade funcional. A Quebec Back Pain Disability Scale (QBPDS) é um instrumento amplamente aceite a nível internacional na medição do nível de incapacidade funcional reportada pelos indivíduos com DLC. O objetivo deste estudo é dar um contributo para a adaptação cultural da versão portuguesa da QBPDS (QBPDS-VP) e investigar o poder de resposta e interpretabilidade da escala. Metodologia: Realizou-se um estudo metodológico, multicentro, baseado num coorte prospetivo de 132 utentes com DLC. Os utentes foram recrutados a partir da lista de espera de 16 serviços de Medicina Física e de Reabilitação/Fisioterapia de várias áreas geográficas de Portugal. A QBPDS- VP foi administrada 3 vezes, em 3 momentos de recolha de dados distintos: T0 - momento inicial (utentes em lista de espera); T1 - 1 semana de intervalo (início dos tratamentos de Fisioterapia); e T2 - 6 semanas de intervalo (pós-intervenção de Fisioterapia). Os dados recolhidos em T0 foram utilizados para a análise fatorial e para o estudo da consistência interna (n=132); os dados da amostra emparelhada de T0 e T1 (n=132) para a fiabilidade teste-reteste; e os dados da amostra emparelhada de T0 e T2 (n=120) para a análise do poder de resposta e interpretabilidade. A âncora externa utilizada foi a perceção global de mudança, neste caso a PGIC- VP, que foi respondida em T1 e T2. O nível de significância para o qual os valores se consideraram satisfatórios foi de p≤ 0,05. O tratamento dos dados foi realizado no software IBM SPSS Statistics (versão 20). Resultados: A QBPDS- VP é uma escala unidimensional, que revela uma excelente consistência interna (α de Cronbach= 0,95) e uma fiabilidade teste-reteste satisfatória (CCI= 0,696; IC 95%: 0,581–0,783). Esta escala demonstrou um poder de resposta moderado, quando aplicada em utentes com DLC ( = 0,426 e AAC= 0,741; IC 95%: 0,645 – 0,837). A Diferença Mínima Detetável (DMD) estimada foi de 19 pontos e as estimativas da Diferença Mínima Clinicamente Importante (DMCI) variaram entre 7 (pelo método curva ROC) e 8 pontos (pelo método “diferença média de pontuação”). A estimativa pela curva ROC deriva do ponto ótimo de corte de 6,5 pontos, com Área Abaixo da Curva (AAC)= 0,741, sensibilidade de 72%, e especificidade de 71%. Uma análise complementar da curva ROC baseada nas diferenças de pontuações da QBPDS, expressa em percentagem, revelou um ponto ótimo de corte de - 24% (AAC= 0,737, sensibilidade de 71%, e especificidade de 71%). Para pontuações iniciais da QBPDS- VP mais altas (≥34 pontos), foi encontrado um ponto ótimo de corte de 10,5 pontos (AAC= 0,738, sensibilidade de 73%, e especificidade de 67%). Conclusão: A QBPDS-VP demonstrou bons níveis de fiabilidade e poder de resposta, recomendando-se o seu uso na medição e avaliação da incapacidade funcional de utentes com DLC. A DMD estimada, de 19 pontos, determinou uma amplitude válida da QBPDS-VP de 19 a 81 pontos. Este estudo propõe estimativas de DMCI da QBPDS- VP numa aplicação específica da escala (em utentes com DLC que são referidos para a intervenção de Fisioterapia). A pontuação inicial da QBPDS- VP deve ser considerada na interpretação de mudanças de pontuação, após a intervenção de Fisioterapia.------------ ABSTRACT: One of the main results of physiotherapy interventions for patients with Chronic Low Back Pain (CLBP) is decrease the functional disability. The Quebec Back Pain Disability Scale (QBPDS) is an instrument widely accepted internationally, in measuring the level of disability reported by individuals with CLBP. The purpose of this study is to contribute to the cultural adaptation of the Portuguese version of QBPDS (QBPDS - PV) and investigate the Responsiveness and Interpretability of QBPDS-PV. Methodology: This was a methodological and multicenter study, based on a sample of 132 subjects with CLBP. The patients were recruited from the waiting lists of 16 medicine rehabilitation service, in many Portugal districts. The Quebec Back Pain Disability Scale was administered in three different moments: T0 – baseline (patients in the waiting list); T1- one week after T0 (the beginning of treatment); and T2 – six weeks after T1 (the posttreatment). The data collected at T0 were used for factor analysis and to study the internal consistency (n = 132); paired sample data of T0 and T1 (n=132) were used for test-retest reliability, and sample data paired for T0 and T2 (n=120) used for responsiveness and interpretability analysis. The external anchor was the global perception of change, measured by the Portuguese version of Patient’s Global Impression of Change (PGIC) Scale. The minimal level of significance established was p ≤ 0,05. Data analysis was performed using the IBM SPSS Statistics software (version 20). Results: The QBPDS-PV is a unidimensional scale, demonstrates an excellent internal consistency (Cronbach's α=0.95) and satisfactory test-retest reliability (ICC= 0.696, 95% CI: 0.581–0.783). The scale revealed moderate responsiveness when applied to patients with CLBP ( = 0.426 and AUC= 0.741, 95% CI: 0.645 - 0.837). The Smallest Detectable Change (SDC) was 19 points, whereas the Minimal Clinically Important Change (MCIC) ranged between 7 (ROC curve method) and 8 points (by the "mean difference score"). The estimate was derived from the ROC curve by an optimal cutoff point of 6.5 points, with Area Under the Curve (AUC)= 0.741, sensitivity 72%, and specificity of 71%. A complementary analysis of the ROC curve based on differences in QBPDS scores from baseline, expressed in percentage, revealed an optimal cutoff point of -24% (AUC= 0.737, sensitivity of 71%, and specificity of 71%). For the highest initial scores of QBPDS-PV (≥ 34 points) was found an optimal cutoff of 10.5 points (AUC= 0.738, sensitivity of 73%, and specificity 67%). Conclusion: The QBPDS-PV demonstrated good levels of reliability and responsiveness, being recommended its use in the measurement and evaluation of disability of patients with CLBP. The SDC of 19 points determined the QBPDS‟ scale width of 19 to 81. This study proposes MCIC values for QBPDS –PV for this specific setting (in CLBP patients who are referred for physiotherapy intervention). The QBPDS –PV baseline score have to be taken into account while interpreting the score change after physiotherapy intervention.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RESUMO: Introdução: A relação cinemática entre as articulações do CAO apresenta grande importância na função do MS, e é por isso cada vez mais investigada e descrita. O posicionamento da omoplata ganha um importante papel para compreender as DCAO. É indiscutível o importante papel da omoplata na dinâmica do MS, bem como o posicionamento escapular como parâmetro clínico de disfunção do CAO. Todos estes factores criam a necessidade de desenvolver instrumentos de avaliação da posição da articulação ET. A grande maioria dos testes de avaliação, restringem a sua avaliação às disfunções da articulação GU, não integrando uma avaliação mais dinâmica e interactiva que respeite os pressupostos teóricos inerentes ao REU. È importante também que os métodos de avaliação sejam de fácil aplicabilidade clínica e que avaliem fidedignamente e com validade os outcomes. Objectivos: Contribuir para o desenvolvimento de uma metodologia de avaliação da omoplata em diferentes amplitudes do MS, através do estudo da validade concorrente, da fidedignidade intra e inter-observador. Metodologia: A amostra foi constituída por 20 elementos seleccionados por conveniência, entre o corpo de discentes da ESS-IPS, sem história de disfunção do CAO. Foi realizada uma análise cinemática ao MS de cada sujeito, usando um aparelho de análise por varrimento electromagnético, o FOB. Em cada sujeito foram ainda medidas, as distâncias escapulares em estudo, usando a fita métrica. Cada método de medição foi constituído por dois momento (teste e reteste), em cada momento, as medidas eram recolhidas por dois investigadores distintos. Resultados e Discussão: Foram considerados como positivos os resultados que se apresentassem acima do limiar de 0,5, que classifica uma correlação como moderada a excelente. Os resultados da validade mostram que para o investigador 1 nas medidas M1e M2 apenas houve correlação com valores excelentes a moderados até aos 30º de elevação do MS. Já para M3 apenas aos 30º no plano da omoplata essa mesma correlação não tem valores próximos do cutpoint. Em M4 nenhum valor tem correlação significativa com os valores do FOB, chegando mesmo a haver correlação negativa para os 120º no plano da omoplata. Em M5 apenas os 0º mostram valores correlacionais excelentes a moderados. Para o investigador 2, em M1 e M2 á semelhança do investigador 1, só existem valores de correlação significativos até aos 30º de elevação do MS. Já para M3 todos os valores mostram excelente a moderada correlação á excepção dos 120º no plano frontal. Em M4 este investigador apresenta maus resultados. Já em M5 os valores de correlação são moderados aos 0º e aos 90º. No que diz respeitos aos resultados dos CCI intra-observador,podemos afirmar que foi em M5 que estes valores mais se aproximaram do cut point. M1 e M2 são as medidas onde se encontram resultados menos satisfatórios. É aos 60º que existem valores mais satisfatórios, seguidos pelos 0º e 30º, quando nos aproximamos de graus mais elevados, como 90º e 120º, estes valores tendem a baixar. Quanto á fidedignidade inter-observador para M1 apenas aos 90º e aos 120º houve valores de correlação abaixo do cutpoint. Em M2, só os 60º do plano sagital não teve valores acima do cutpoint, em M3 apenas os 30º plano sagital não obtiveram valores acima do cut-point, o mesmo acontece para M3 aos 30º plano da omoplata e em M5 aos 30º e 120º no plano frontal. Conclusão: Os resultados deste estudo indicam que a metodologia em causa apresenta elevado grau de fidedignidade inter-observador, já no que toca é fidedignidade intra-observador o grau de semelhança não é tão elevado. Também o erro associado á medida não ultrapassou 1,5cm, sendo considerado baixo. Na validade concorrente concluímos que é aos 0º que a metodologia se torna uma opção válida na aferição das distâncias medidas com uma boa a excelente concordância com o FOB. As medidas consideradas como opções válidas, nas diferentes amplitudes, podem funcionar como parâmetros clínicos de caracterização do posicionamento da omoplata, podendo vir a contribuir ainda para a caracterização da orientação da mesma.-------------------- ABSTRACT:Introduction: The kinematic relationship between the joints of the CAO has great importance in the function of MS, which is why more and more investigated and described. The positioning of the blade gets an important role in understanding the DCAO. There is no doubt the important role of the scapula in the dynamics of MS as well as the positioning of scapular dysfunction as a clinical parameter of the CAO. All these factors create the need to develop tools for evaluating the place of articulation ET. Most assessment tests, restrict its assessment to GU joint disorders, not incorporating a more dynamic and interactive way that respects the theoretical assumptions inherent in the REU. It is also important that the methods are easy to apply clinical and reliably to assess the validity and outcomes. Objectives: To contribute to the development of a methodology for evaluating the scapula in different ranges of MS, through the study of concurrent validity, reliability of intra-and inter-observer. Methodology: The sample consisted of 20 selected elements for convenience, between the body of students of IPS-ESS with no history of dysfunction of the CAO. We performed a kinematic analysis of each subject to MS, using a scanning device for electromagnetic analysis, the FOB. In each subject were also measured, the scapular distances under study, using tape measure. Each method of measuring the time consisted of two (test and retest), in each moment, the measures were collected by two different investigators. Results and Discussion: We considered as positive results that were above the threshold of 0.5, which ranks as a moderate to excellent correlation. The results show that the validity for the researcher in an action M1e M2 was only correlated with moderate to excellent values up to 30º of elevation of the MS. As for M3 only to 30º in the plane of the scapula has the same correlation values near the cutpoint. M4 has no value in correlation with the values of the FOB, and even negative correlation to 120 ° in the plane of the scapula. In M5 show only the values 0 ° correlational excellent to moderate. For investigator 2 in M1 and M2 will be like an investigator, there are only significant correlation values up to 30º of elevation of the MS. As for M3 all the values show excellent correlation to moderate with the exception of 120 ° in the frontal plane. In this researcher M4 has bad results. M5 already in the correlation values are moderate to 0º and 90 º. Regarding the results of ICC intra-observer, we can say that M5 was that these values come closest to the cut point. M1 and M2 are measures which are less than satisfactory results. At 60 ° there are more satisfactory values, followed by 0º and 30º, when we approached the highest levels, such as 90 ° and 120 °, these values tend to decrease. The inter-observer reliability for M1 only to 90 º and 120 ºcorrelation values were below the cutpoint. In M2, only 60 of the sagital plane did not have values above the cutpoint in M3 only 30º sagital plane did not obtain values above the cut-point, the same goes for M3 at 30 ° plane of the scapula and M5 at 30 º and 120 º in frontal plane. Conclusion: The results of this study indicate that the methodology in question has a high degree of inter-observer reliability, as far as intra-observer reliability is the degree of similarity is not as high. Also the error of measure did not exceed 1.5 cm, and is considered low. In concurrent validity conclude that it is at 0 ° the methodology becomes a valid option for the measurement of distances measured with a good to excellent agreement with the FOB. The measures considered as valid options in different amplitudes, can function as clinical parameters to characterize the positioning of the shoulder blade and could further contribute to the characterization of the orientation of the same.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertation to obtain the Master Degree in Biotechnology

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Work Project, presented as part of the requirements for the Award of a Masters Degree in Finance from the NOVA – School of Business and Economics

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Work Project, presented as part of the requirements for the Award of a Masters Degree in Economics from the NOVA – School of Business and Economics

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Work Project, presented as part of the requirements for the Award of a Masters Degree in Economics from the NOVA – School of Business and Economics

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Work Project, presented as part of the requirements for the Award of a Masters Degree in Finance from the NOVA – School of Business and Economics