34 resultados para IPS-Empress ceramic


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intern.Conference AZULEJAR, Univ. Aveiro, 10-12 October 2012

Relevância:

20.00% 20.00%

Publicador:

Resumo:

3rd Historic Mortars Conference, 11-14 September 2013, Glasgow, Scotland

Relevância:

20.00% 20.00%

Publicador:

Resumo:

9th International Masonry Conference 2014, 7-9 July, Universidade do Minho, Guimarães

Relevância:

20.00% 20.00%

Publicador:

Resumo:

XIII DBMC – 12th International Conference on Durability of Building Materials and Components,2-5 September 2014, Universidade de São Paulo, São Paulo, Brazil

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The formulation and use of lime mortars with ceramic particles has, in the past, been a very common technique. Knowledge of such used techniques and materials is fundamental for the successful rehabilitation and conservation of the built heritage. The durability that these mortars have shown encourages the study of the involved mechanisms, so that they may be adapted to the current reality. The considerable amount of waste from old ceramics factories which is sent for disposal might present an opportunity for the production of reliable improved lime mortars. In this paper a number of studies that characterize old building mortars containing ceramic fragments are reviewed. The most important research undertaken on laboratory prepared mortars with several heat treated clays types is presented, specifically with incorporated ceramic waste. Some studies on the pozzolanicity of heat treated clays are examined and the heating temperatures that seem most likely to achieve pozzolanicity are presented. It was verified that some heating temperatures currently used by ceramic industries might correspond to the temperatures that will achieve pozzolanicity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Considering the fundamental importance of preserving the built heritage and of ensuring the good performance achieved by incorporating ceramic particles in lime mortars in ancient times, it is important to study solutions that use materials the available today, in order to produce mortars intended to repair and replace the old ones. Solutions incorporating industrial ceramic waste might be profitable for several reasons, namely for economic, environmental and technical aspects. In this paper, seven ceramic waste products collected from ceramics factories are characterized. Their mineralogy, dimensional features and pozzolanicity were determined. Three of these products, with different particle size fractions (obtained directly from milling, dust only and fragment fractions only), were selected, incorporated into air lime mortars, and their mechanical strength was determined. In the present work, evidence of mechanical efficiency, when common sand or air lime were partially replaced by ceramic wastes, was made clear, drawing attention to the sustainability of this type of mortars, hence, encouraging further research.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Due to their exposure to environmental conditions, outer coatings composed by render and painting system are usually the first construction elements to deteriorate and require intervention. A correct conservation and rehabilitation of these materials is fundamental once they provide protection to other façade materials. It is known that old mortar renders were essentially air lime based mortars. To maintain the integrity of the whole wall-render elements, the image of the building and to avoid accelerated degradation, conservation and rehabilitation must be implemented with compatible mortars. As that, lime based mortars would be preferable. It was also common, in ancient renders, the incorporation of ceramic residues, which is, nowadays, an abundant material, especially in Central Region of Portugal. The reuse of these materials has great relevance once their landfilling causes serious environmental issues. In an attempt to combine the environmental and technical advantages of the use of ceramic waste in mortars’ production for rehabilitation purposes, a research has been developed at the University of Coimbra, in cooperation with Nova University of Lisbon, on the long term behaviour of air lime mortars with ceramic residues. In this paper the most significant up to one year results of an experimental campaign with air lime mortars with 1:3 and 1:2 volumetric proportions and ceramic residues are presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Transparent conducting oxides (TCOs) have been largely used in the optoelectronic industry due to their singular combination of low electrical resistivity and high optical transmittance. They are usually deposited by magnetron sputtering systems being applied in several devices, specifically thin film solar cells (TFSCs). Sputtering targets are crucial components of the sputtering process, with many of the sputtered films properties dependent on the targets characteristics. The present thesis focuses on the development of high quality conductive Al-doped ZnO (AZO) ceramic sputtering targets based on nanostructured powders produced by emulsion detonation synthesis method (EDSM), and their application as a TCO. In this sense, the influence of several processing parameters was investigated from the targets raw-materials synthesis to the application of sputtered films in optoelectronic devices. The optimized manufactured AZO targets present a final density above 99 % with controlled grain size, an homogeneous microstructure with a well dispersed ZnAl2O4 spinel phase, and electrical resistivities of ~4 × 10-4 Ωcm independently on the Al-doping level among 0.5 and 2.0 wt. % Al2O3. Sintering conditions proved to have a great influence on the properties of the targets and their performance as a sputtering target. It was demonstrated that both deposition process and final properties of the films are related with the targets characteristics, which in turn depends on the initial powder properties. In parallel, the influence of several deposition parameters in the film´s properties sputtered from these targets was investigated. The sputtered AZO TCOs showed electrical properties at room temperature that are superior to simple oxides and comparable to a reference TCO – indium tin oxide (ITO), namely low electrical resistivity of 5.45 × 10-4 Ωcm, high carrier mobility (29.4 cm2V-1s-1), and high charge carrier concentration (3.97 × 1020 cm-3), and also average transmittance in the visible region > 80 %. These superior properties allowed their successful application in different optoelectronic devices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With the increasing importance given to building rehabilitation comes the need to create simple, fast and non-destructive testing methods (NDT) to identify problems and for anomaly diagnosis. Ceramic tiles are one of the most typical kinds of exterior wall cladding in several countries; the earliest known examples are Egyptian dating from 4000 BC. This type of building facade coating, though being quite often used in due to its aesthetic and architectural characteristics, is one of the most complex that can be applied given the several parts from which it is composed; hence, it is also one of the most difficult to correctly diagnose with expeditious methods. The detachment of ceramic wall tiles is probably the most common and difficult to identify anomaly associated with this kind of cladding and it is also definitely the one that can compromise security the most. Thus, it is necessary to study a process of inspection more efficient and economic than the currently used which often consist in semi-destructive methods (the most common is the pull off test), that can only be used in a small part of the building at a time, allowing some assumptions of what can the rest of the cladding be like. Infrared thermography (IRT) is a NDT with a wide variety of applications in building inspection that is becoming commonly used to identify anomalies related with thermal variations in the inspected surfaces. Few authors have studied the application of IRT in anomalies associated with ceramic claddings claiming that the presence of air or water beneath the superficial layer will influence the heat transfer in a way that can be detected in both a qualitative and a quantitative way by the thermal camera, providing information about the state of the wall in a much broad area per trial than other methods commonly used nowadays. This article intends to present a review of the state of art of this NDT and its potentiality in becoming a more efficient way to diagnose anomalies in ceramic wall claddings.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para a Obtenção do grau de Mestre em Ciências da Educação/ Educação e Desenvolvimento

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Engenharia Mecânica

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Proceedings of the Chemistry and Conservation Science

Relevância:

10.00% 10.00%

Publicador:

Resumo:

RESUMO: Introdução: A dor e disfunções do movimento no complexo articular do ombro (CAO) são comuns e debilitantes. O uso de exercícios segundo os pressupostos de estabilidade dinâmica (ED), com auxílio de Biofeedback electromiográfico (BEMG) tem vindo a ser referido, como uma forma de aumentar a efectividade da intervenção nas disfunções do complexo articular do ombro (DCAO)Objectivo Principal: Estudar os efeitos de um protocolo de intervenção, com BEMG, cujas finalidades foram abolir a dor, aumentar a funcionalidade e a ED da omoplata, em utentes com DCAO. Objectivos secundários: Comparar os subgrupos e quanto às características, resultados, tempos de intervenção total e até atingir critérios de alta; Comparar os resultados nos momentos inicial e final. Métodos: Foi realizado um coorte clínico, longitudinal, retrospectivo, observacional, analítico. A amostra foi constituída por 82 sujeitos, divididos em dois subgrupos (n=53 SCSA e n=29 IGU). Os instrumentos de medida utilizados foram a EVA, o DASH, o SPADI e o BEMG. Foi seguido o protocolo de ED proposto por Santos e Matias (2007), de acordo com as 3 fases de intervenção por eles descritas, realizando uma sessão semanal, monitorizando exercícios que seguem estes princípios, com BEMG. Foram avaliadas as variáveis dor, postura, padrão de recrutamento, controlo motor, posição inicial da omoplata (PIO), amplitudes articulares (AA’s), força muscular (FM) e postura. Para analisar os dados, recorreu-se a estatística descritiva e inferencial. Resultados: A intervenção foi efectiva na abolição da dor no momento (0,43 para 0,00/10EVA no subgrupo SCSA e 0,66 para 0,00/10EVA no subgrupo IGU) na pior dor (5,47/10EVA para 0,06/10EVA no subgrupo SCSA e 5,28/10 para 0,14/10 no subgrupo IGU), no aumento da função (28,57 para 0,66/100DASH e 39,00 para 0,63/100SAPDI no subgrupo SCSA e 25,80 para 0,38/100DASH e 28,19 para 0,39/100 no subgrupo IGU) e no aumento da ED da omoplata com normalização do padrão de recrutamento, controlo motor, PIO dentro do espectro de normalidade e boa capacidade de controlar a sua posição, ao longo do movimento do membro superior (MS). A intervenção proporcionou, ainda a normalização das AA’s, FM e autocorrecção postural. O tempo médio de intervenção foi de 6,45semanas no subgrupo SCSA e 5,83sem no subgrupo IGU. Estes resultados são semelhantes comparativamente a estudos que utilizaram uma intervenção baseada nos mesmos princípios (Matias e Cruz, 2004; Cunha e Matias, 2006; Santos e Matias, 2007; Rodrigues e Matias, 2009). Conclusão: O protocolo de intervenção aplicado, com uso de exercícios baseados nos princípios da ED e uso de BEMG, permitiu o alcance dos objectivos, junto de utentes com DCAO (SCSA e IGU). Verificou-se que, independentemente da condição, os resultados foram idênticos em ambos subgrupos, não apresentando diferenças significativas entre as variáveis de medida final, o tempo total de intervenção e os tempos até atingir os critérios de alta, expecto para a Dor, sendo este superior no subgrupo SCSA.---------------------------------------- ABSTRACT:Introduction: Movement disorders and pain in the shoulder joint complex (SJC) are common and debilitating. The use of exercises under the premises of dynamic stability (DS), with the aid of electromyographic biofeedback (EMGBF) has been mentioned as a way to increase the effectiveness of the intervention in disorders of the shoulder joint complex (DSJC) Main Objective: To evaluate the results of an intervention protocol, with EMGBF whose aims were to abolish the pain, increase functionality and DS of the scapula in patients with DSJC. Objectives: To compare the subgroups and the characteristics, outcomes, and total intervention times to reach discharge criteria; to compare the results at the beginning and at the end. Methods: We conducted a clinical cohort, longitudinal, retrospective, observational analysis. The sample consisted of 82 subjects, divided into two subgroups (n = 53 shoulder impingement syndrome SIS n = 29 shoulder joint instability SJI). The measurement instruments used were the VAS, DASH, SPADI, and EMGBF. It was followed the DS protocol proposed by Santos and Matias (2007), according to the three phases of intervention, described by performing a weekly session, monitoring exercises that follow these principles, with EMGBF. The variables were pain, posture, recruitment pattern, motor control, the initial position of the scapula (IPS), range of motion (ROM), muscular strength (MS) and posture. To analyze the data, we used the descriptive and inferential statistics. Results: The intervention was effective in abolishing the pain at the time (0.43 to 0.00/10 VAS in the SIS subgroup and 0.66 to 0.00/10 VAS in the SJI subgroup) in worst pain (5.47 to 0,06/10 VAS in the SIS subgroup and 5.28/ to 0.14/10 VAS in the SJI subgroup), increasing the function (28,57 to 0,66/100 DASH and 39,00 to 0,63/100 SAPDI in the SIS subgroup and 25,80 to 0,38/100 DASH and 28,19 to 0,39/100 SPADI in the SJI subgroup) and the increase in DS of the scapula with normalization of the pattern recruitment, motor control, IPS within the spectrum of normalcy and good ability to control its position along the movement of the upper limb (UL). The intervention provided, although the normalization of ROM, MS and self-correcting posture. The average length of intervention was 6.45 weeks in the SIS subgroup and 5.83 in the IS subgroup. These results are comparable with similar studies that used an intervention based on the same principles (Matias e Cruz, 2004; Cunha e Matias, 2006; Santos e Matias, 2007; Rodrigues e Matias, 2009). Conclusion: The intervention protocol implemented with the use of exercises based on the principles of DS and the use of EMGBF was effective, allowing the accomplishment of goals, in patients with DSJC (SIS and SJI). It was found that, regardless of condition, the results were identical in both groups, showing no significant differences between the variables of the final measure, the total time of intervention and the times to reach discharge criteria, except for pain, which was higher in the SIS subgroup.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

RESUMO: Introdução: A relação cinemática entre as articulações do CAO apresenta grande importância na função do MS, e é por isso cada vez mais investigada e descrita. O posicionamento da omoplata ganha um importante papel para compreender as DCAO. É indiscutível o importante papel da omoplata na dinâmica do MS, bem como o posicionamento escapular como parâmetro clínico de disfunção do CAO. Todos estes factores criam a necessidade de desenvolver instrumentos de avaliação da posição da articulação ET. A grande maioria dos testes de avaliação, restringem a sua avaliação às disfunções da articulação GU, não integrando uma avaliação mais dinâmica e interactiva que respeite os pressupostos teóricos inerentes ao REU. È importante também que os métodos de avaliação sejam de fácil aplicabilidade clínica e que avaliem fidedignamente e com validade os outcomes. Objectivos: Contribuir para o desenvolvimento de uma metodologia de avaliação da omoplata em diferentes amplitudes do MS, através do estudo da validade concorrente, da fidedignidade intra e inter-observador. Metodologia: A amostra foi constituída por 20 elementos seleccionados por conveniência, entre o corpo de discentes da ESS-IPS, sem história de disfunção do CAO. Foi realizada uma análise cinemática ao MS de cada sujeito, usando um aparelho de análise por varrimento electromagnético, o FOB. Em cada sujeito foram ainda medidas, as distâncias escapulares em estudo, usando a fita métrica. Cada método de medição foi constituído por dois momento (teste e reteste), em cada momento, as medidas eram recolhidas por dois investigadores distintos. Resultados e Discussão: Foram considerados como positivos os resultados que se apresentassem acima do limiar de 0,5, que classifica uma correlação como moderada a excelente. Os resultados da validade mostram que para o investigador 1 nas medidas M1e M2 apenas houve correlação com valores excelentes a moderados até aos 30º de elevação do MS. Já para M3 apenas aos 30º no plano da omoplata essa mesma correlação não tem valores próximos do cutpoint. Em M4 nenhum valor tem correlação significativa com os valores do FOB, chegando mesmo a haver correlação negativa para os 120º no plano da omoplata. Em M5 apenas os 0º mostram valores correlacionais excelentes a moderados. Para o investigador 2, em M1 e M2 á semelhança do investigador 1, só existem valores de correlação significativos até aos 30º de elevação do MS. Já para M3 todos os valores mostram excelente a moderada correlação á excepção dos 120º no plano frontal. Em M4 este investigador apresenta maus resultados. Já em M5 os valores de correlação são moderados aos 0º e aos 90º. No que diz respeitos aos resultados dos CCI intra-observador,podemos afirmar que foi em M5 que estes valores mais se aproximaram do cut point. M1 e M2 são as medidas onde se encontram resultados menos satisfatórios. É aos 60º que existem valores mais satisfatórios, seguidos pelos 0º e 30º, quando nos aproximamos de graus mais elevados, como 90º e 120º, estes valores tendem a baixar. Quanto á fidedignidade inter-observador para M1 apenas aos 90º e aos 120º houve valores de correlação abaixo do cutpoint. Em M2, só os 60º do plano sagital não teve valores acima do cutpoint, em M3 apenas os 30º plano sagital não obtiveram valores acima do cut-point, o mesmo acontece para M3 aos 30º plano da omoplata e em M5 aos 30º e 120º no plano frontal. Conclusão: Os resultados deste estudo indicam que a metodologia em causa apresenta elevado grau de fidedignidade inter-observador, já no que toca é fidedignidade intra-observador o grau de semelhança não é tão elevado. Também o erro associado á medida não ultrapassou 1,5cm, sendo considerado baixo. Na validade concorrente concluímos que é aos 0º que a metodologia se torna uma opção válida na aferição das distâncias medidas com uma boa a excelente concordância com o FOB. As medidas consideradas como opções válidas, nas diferentes amplitudes, podem funcionar como parâmetros clínicos de caracterização do posicionamento da omoplata, podendo vir a contribuir ainda para a caracterização da orientação da mesma.-------------------- ABSTRACT:Introduction: The kinematic relationship between the joints of the CAO has great importance in the function of MS, which is why more and more investigated and described. The positioning of the blade gets an important role in understanding the DCAO. There is no doubt the important role of the scapula in the dynamics of MS as well as the positioning of scapular dysfunction as a clinical parameter of the CAO. All these factors create the need to develop tools for evaluating the place of articulation ET. Most assessment tests, restrict its assessment to GU joint disorders, not incorporating a more dynamic and interactive way that respects the theoretical assumptions inherent in the REU. It is also important that the methods are easy to apply clinical and reliably to assess the validity and outcomes. Objectives: To contribute to the development of a methodology for evaluating the scapula in different ranges of MS, through the study of concurrent validity, reliability of intra-and inter-observer. Methodology: The sample consisted of 20 selected elements for convenience, between the body of students of IPS-ESS with no history of dysfunction of the CAO. We performed a kinematic analysis of each subject to MS, using a scanning device for electromagnetic analysis, the FOB. In each subject were also measured, the scapular distances under study, using tape measure. Each method of measuring the time consisted of two (test and retest), in each moment, the measures were collected by two different investigators. Results and Discussion: We considered as positive results that were above the threshold of 0.5, which ranks as a moderate to excellent correlation. The results show that the validity for the researcher in an action M1e M2 was only correlated with moderate to excellent values up to 30º of elevation of the MS. As for M3 only to 30º in the plane of the scapula has the same correlation values near the cutpoint. M4 has no value in correlation with the values of the FOB, and even negative correlation to 120 ° in the plane of the scapula. In M5 show only the values 0 ° correlational excellent to moderate. For investigator 2 in M1 and M2 will be like an investigator, there are only significant correlation values up to 30º of elevation of the MS. As for M3 all the values show excellent correlation to moderate with the exception of 120 ° in the frontal plane. In this researcher M4 has bad results. M5 already in the correlation values are moderate to 0º and 90 º. Regarding the results of ICC intra-observer, we can say that M5 was that these values come closest to the cut point. M1 and M2 are measures which are less than satisfactory results. At 60 ° there are more satisfactory values, followed by 0º and 30º, when we approached the highest levels, such as 90 ° and 120 °, these values tend to decrease. The inter-observer reliability for M1 only to 90 º and 120 ºcorrelation values were below the cutpoint. In M2, only 60 of the sagital plane did not have values above the cutpoint in M3 only 30º sagital plane did not obtain values above the cut-point, the same goes for M3 at 30 ° plane of the scapula and M5 at 30 º and 120 º in frontal plane. Conclusion: The results of this study indicate that the methodology in question has a high degree of inter-observer reliability, as far as intra-observer reliability is the degree of similarity is not as high. Also the error of measure did not exceed 1.5 cm, and is considered low. In concurrent validity conclude that it is at 0 ° the methodology becomes a valid option for the measurement of distances measured with a good to excellent agreement with the FOB. The measures considered as valid options in different amplitudes, can function as clinical parameters to characterize the positioning of the shoulder blade and could further contribute to the characterization of the orientation of the same.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertation presented to Faculdade de Ciências e Tecnologia, Universidade Nova de Lisboa for obtaining the master degree in Membrane Engineering