12 resultados para Energy performance rating


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Dissertation submitted in partial fulfillment of the requirements for the Degree of Master of Science in Geospatial Technologies.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A União Europeia tem dado cada vez mais enfoque à eficiência energética nos edifícios e à sua capacidade de produção de energia, tendo lançado a directiva “Energy Performance of Buildings Directive” com o intuito de que até 31 de Dezembro de 2018 todos os edifícios novos sejam “nZEB-nearly Zero Energy Building”, o que significa que devem por um lado diminuir o seu consumo energético, aumentando a sua eficiência, e por outro lado produzir localmente e através de fontes de energias renováveis toda, ou quase toda, a energia de que necessitam. A presente tese está integrada no Projecto “Frame – Prefabricated systems (modules) for low-energy buildings: design, prototyping and testing” (Ref: PTDC/AURAQI-AQI/117782/2010) que está a ser desenvolvido na Unidade de Eficiência Energética do Laboratório Nacional de Energia e Geologia (LNEG). Neste trabalho é desenvolvido e analisado um sistema BIPV/T-PCM (Building Integrated Photovoltaic Thermal – Phase Change Materials) que engloba todo um novo conceito de captação, armazenamento e gestão da energia solar em fachadas. Este sistema é composto por um módulo fotovoltaico, uma bateria de PCM (Materiais de Mudança de Fase) e todo um sistema de fluxo de ar que permite a gestão da energia colectada e armazenada. Foi também desenvolvido teoricamente um código de gestão energética para a manipulação do sistema. O sistema em estudo apoia-se em três objectivos principais: aquecer no inverno; arrefecer no verão; e aumentar a eficiência do PV arrefecendo-o. Na sequência do trabalho realizado verificou-se que o conceito do sistema em estudo alcança alguns dos objectivos propostos, tendo ainda potencial para se continuar o seu desenvolvimento. O sistema em estudo é um sistema inovador, e como tal está a ser registada uma patente com base no conceito desenvolvido.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper examines the impact of Sovereign rating changes on the aggregate stock and bond market returns both in emerging and developed countries. Rating downgrades in emerging markets are associated with significant negative wealth effects both in the stock and bond markets. Moreover, the effects of rating downgrades persist up to six-months after the event. In contrast, upgrades in emerging markets convey no information. Rating changes in developed markets have no significant impact on either stock and bond market returns. Rating agencies act pro-cyclically, downgrading countries in bad times and, consequently, contributing to the instability in emerging markets.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Due to global warming and shrinking fossil fuel resources, politics as well as society urge for a reduction of green house gas (GHG) emissions. This leads to a re-orientation towards a renewable energy sector. In this context, innovation and new technologies are key success factors. Moreover, the renewable energy sector has entered a consolidation stage, where corporate investors and mergers and acquisitions (M&A) gain in importance. Although both M&A and innovation in the renewable energy sector are important corporate strategies, the link between those two aspects has not been examined before. The present thesis examines the research question how M&A influence the acquirer’s post-merger innovative performance in the renewable energy sector. Based on a framework of relevant literature, three hypotheses are defined. First, the relation between non-technology oriented M&A and post-merger innovative performance is discussed. Second, the impact of absolute acquired knowledge on postmerger innovativeness is examined. Third, the target-acquirer relatedness is discussed. A panel data set of 117 firms collected over a period of six years has been analyzed via a random effects negative binomial regression model and a time lag of one year. The results support a non-significant, negative impact of non-technology M&A on postmerger innovative performance. The applied model did not support a positive and significant impact of absolute acquired knowledge on post-merger innovative performance. Lastly, the results suggest a reverse relation than postulated by Hypothesis 3. Targets from the same industry significantly and negatively influence the acquirers’ innovativeness.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dissertação apresentada na faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para a obtenção do grau de Mestre em Engenharia Electrotécnica e de Computadores

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Journal of Environmental Management, nº 82 p. 410–432

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia do Ambiente Perfil de Gestão e Sistemas Ambientais

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Doutor em Engenharia Electrotécnica e Computadores

Relevância:

30.00% 30.00%

Publicador:

Resumo:

High reflective paints (cool paints) are used on flat roofs to reduce heat gains from the incidence of solar radiation and thus improve the thermal comfort and energy efficiency of buildings, especially in summer periods. Given the application potential of these paints on vertical surfaces, a research study has been developed to evaluate the thermal performance of reflective paints on walls under real exposure conditions. Accordingly, different reflective paints have been applied as the final coating of an ETICS type solution, on the facades of a full scale experimental cell built at LNEC campus. For being applied in an ETICS system a paint has to fulfill several requirements, whether aesthetic or functional (such as the adhesion between the coating layers or the durability of the insulation), essential for its efficient performance. Since this construction coating system is subject to a prolonged sun exposure, various problems may arise, such as paint degradation or deterioration of the thermal insulation properties, particularly when dark colors are applied. To evaluate the thermal performance of the chosen paints, the method of non-destructive analysis by Infrared Thermography was used. Thermography allows knowing the temperature distribution of facades by measuring the radiation emitted by their surfaces. To complement the thermographic diagnosis, thermocouples were placed between the insulation and the paint system of the experimental cell. Additional laboratory tests allowed the characterization of the optical properties (reflectance and emittance) of the different reflective paints used in this study. The comparative analysis of the thermal performance of reflective and conventional paints revealed that the reflective paint allows a reduction of the facade surface temperature, reducing the risk of loss of insulating properties of the ETICS system and thus ensuring its longevity and functionality. The color of the paint used affects, naturally, the reflective ability of the surface and may have an important role in energy balance of the building. This paper also showed the potential of infrared thermography in the evaluation of the thermal performance of reflective paints.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Scarcity of fuels, changes in environmental policy and in society increased the interest in generating electric energy from renewable energy sources (RES) for a sustainable energy supply in the future. The main problem of RES as solar and wind energy, which represent a main pillar of this transition, is that they cannot supply constant power output. This results inter alia in an increased demand of backup technologies as batteries to assure electricity system safety. The diffusion of energy storage technologies is highly dependent on the energy system and transport transition pathways which might lead to a replacement or reconfiguration of embedded socio-technical practices and regimes (by creating new standards or dominant designs, changing regulations, infrastructure and user patterns). The success of this technology is dependent on hardly predictable future technical advances, actor preferences, development of competing technologies and designs, diverging interests of actors, future cost efficiencies, environmental performance, the evolution of market demand and design and evolution of our society.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Clayish earth-based mortars can be considered eco-efficient products for indoor plastering since they can contribute to improve important aspects of building performance and sustainability. Apart from being products with low embodied energy when compared to other types of mortars used for interior plastering, mainly due to the use raw clay as natural binder, earth-based plasters may give a significant contribution for health and comfort of inhabitants. Due to high hygroscopicity of clay minerals, earth-based mortars present a high adsorption and desorption capacity, particularly when compared to other type of mortars for interior plastering. This capacity allows earth-based plasters to act as a moisture buffer, balancing the relative humidity of the indoor environment and, simultaneously, acting as a passive removal material, improving air quality. Therefore, earth-based plasters may also passively promote the energy efficiency of buildings, since they may contribute to decreasing the needs of mechanical ventilation and air conditioning. This study is part of an ongoing research regarding earth-based plasters and focuses on mortars specifically formulated with soils extracted from Portuguese ‘Barrocal’ region, in Algarve sedimentary basin. This region presents high potential for interior plastering due to regional geomorphology, that promote the occurrence of illitic soils characterized by a high adsorption capacity and low expansibility. More specifically, this study aims to assess how clayish earth and sand ratio of mortars formulation can influence the physical and mechanical properties of plasters. For this assessment four mortars were formulated with different volumetric proportions of clayish earth and siliceous sand. The results from the physical and mechanical characterization confirmed the significantly low linear shrinkage of all the four mortars, as well as their extraordinary adsorption-desorption capacity. These results presented a positive correlation with mortars´ clayish earth content and are consistent with the mineralogical analysis, that confirmed illite as the prevalent clay mineral in the clayish earth used for this study. Regarding mechanical resistance, although the promising results of the adhesion test, the flexural and compressive strength results suggest that the mechanical resistance of these mortars should be slightly improved. Considering the present results the mortars mechanical resistance improvement may be achieved through the formulation of mortars with higher clayish earth content, or alternatively, through the addition of natural fibers to mortars formulation, very common in this type of mortars. Both those options will be investigated in future research.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The considerable amount of energy consumed on Earth is a major cause for not achieving sustainable development. Buildings are responsible for the highest worldwide energy consumption, nearly 40%. Strong efforts have been made in what concerns the reduction of buildings operational energy (heating, hot water, ventilation, electricity), since operational energy is so far the highest energy component in a building life cycle. However, as operational energy is being reduced the embodied energy increases. One of the building elements responsible for higher embodied energy consumption is the building structural system. Therefore, the present work is going to study part of embodied energy (initial embodied energy) in building structures using a life cycle assessment methodology, in order to contribute for a greater understanding of embodied energy in buildings structural systems. Initial embodied energy is estimated for a building structure by varying the span and the structural material type. The results are analysed and compared for different stages, and some conclusions are drawn. At the end of this work it was possible to conclude that the building span does not have considerable influence in embodied energy consumption of building structures. However, the structural material type has influence in the overall energetic performance. In fact, with this research it was possible that building structure that requires more initial embodied energy is the steel structure; then the glued laminated timber structure; and finally the concrete structure.