12 resultados para Brams, Steven J.: The win-win solution
Resumo:
European Journal of Operational Research, nº 73 (1994)
Resumo:
A Work Project, presented as part of the requirements for the Award of a Masters Degree in Management from the NOVA – School of Business and Economics
Resumo:
There were two main objectives in this thesis investigation, first, the production, characterisation, in vitro degradation and release studies of double walled microspheres for drug release control. The second one, and the most challenging, was the production of double walled nanospheres, also for drug control delivery. The spheres were produced using two polymers, the Poly(L-lactide)Acid, PLLA, and the Poly(L-lactide-co-glycolic)Acid, PLGA.Afterwards, a model drug, Meloxicam, which is an antiinflammatory drug, was encapsulated into the particles. Micro and nanospheres were produced by the solvent extraction/evaporation method, where perfect spherical particles were obtained. By varying the polymers PLLA/PLGA mass ratio, different core and shell composition, as well as several shell and core thickness were observed. In the particles with a PLLA/PLGA mass ratio 1:1, the shell is composed by PLLA and the core by PLGA. It was also verified that the Meloxicam has a tendency to be distributed in the PLGA layer. Micro and nanoparticles were characterised in morphology, size, polymer cristalinity properties and drug distribution. Particles degradation studies was performed, where the particles in a PVA solution of pH 7,4 where placed in an incubator, during approximately 40 days, at 120rpm, and 37ºC, simulating, as much as possible, the human body environment. From these studies, the conclusion was that particles containing a PLGA shell and a PLLA core degrade more rapidly, due to the fact that PLLA is more hydrophobic than the PLGA. Concerning the drug release controlled results, done also for 40 and 50 days, they showed that the microspheres containing a shell of PLLA release more slowly than when the shell is composed of PLGA. This result was predictable, since the drug is solubilised in the PLGA polymer and so, in that case, the PLLA shell works like a barrier between the drug and the outer medium. Another positive aspect presented by this study is the lower initial burst effect, obtained when using double walled particles, which is one of the advantages of the same. In a second part of this investigation, the production of the nanospheres was the main goal, since it was not yet accomplished by other authors or investigators. After several studies, referring to the speed, time and type of agitation, as well as, the concentration and volume of the first aqueous solution of poly-vinyl-alcohol (PVA) during the process of solvent extraction/evaporation it was possible to obtain double walled nanospheres.(...)
Resumo:
Mestrado integrado em Engenharia Química e Bioquímica
Resumo:
Thesis submitted to Faculdade de Ciências e Tecnologia from Universidade Nova de Lisboa in partial fulfillment of the requirements for the obtention of the degree of Master of Science in Biotechnology
Resumo:
The aim of this contribution is to extend the techniques of composite materials design to non-linear material behaviour and apply it for design of new materials for passive vibration control. As a first step a computational tool allowing determination of macroscopic optimized one-dimensional isolator behaviour was developed. Voigt, Maxwell, standard and more complex material models can be implemented. Objective function considers minimization of the initial reaction and/or displacement peak as well as minimization of the steady-state amplitude of reaction and/or displacement. The complex stiffness approach is used to formulate the governing equations in an efficient way. Material stiffness parameters are assumed as non-linear functions of the displacement. The numerical solution is performed in the complex space. The steady-state solution in the complex space is obtained by an iterative process based on the shooting method which imposes the conditions of periodicity with respect to the known value of the period. Extension of the shooting method to the complex space is presented and verified. Non-linear behaviour of material parameters is then optimized by generic probabilistic meta-algorithm, simulated annealing. Dependence of the global optimum on several combinations of leading parameters of the simulated annealing procedure, like neighbourhood definition and annealing schedule, is also studied and analyzed. Procedure is programmed in MATLAB environment.
Resumo:
Dissertação para obtenção do Grau de Doutor em Ciência e Engenharia de Materiais
Resumo:
A PhD Dissertation, presented as part of the requirements for the Degree of Doctor of Philosophy from the NOVA - School of Business and Economics
Resumo:
This paper discusses the development of modular solutions for eco low-cost houses based on a pre-fabricated modular wall system environmentally sustainable, socioeconomically competitive and geared towards developing African nations with a housing deficit. The key point to the research of a modular wall solution is a structural layer complemented with local and materials made by non-specialized workforce. This wall also meets also hydrothermal acoustic and mechanical properties. Thus,the solution also offers good safety and interior comfort conditions to its users while maintaining the flexibility to expand the size of the house. Parameters as dimensions, materials and constructive processes of the existing housing stock were studied. Features such as the family size, typology, different uses, common materials, existing regulations, minimal living conditions, safety and comfort have also been considered to achieve the most efficient solution.
Resumo:
The main objective of this work was the development of polymeric structures, gel and films, generated from the dissolution of the Chitin-Glucan Complex (CGC) in biocompatible ionic liquids for biomedical applications. Similar as chitin, CGC is only soluble in some special solvents which are toxic and corrosive. Due to this fact and the urgent development of biomedical applications, the need to use biocompatible ionic liquids to dissolve the CGC is indispensable. For the dissolution of CGC, the biocompatible ionic liquid used was Choline acetate. Two different CGC’s, KiOnutrime from KitoZyme and biologically produced CGC from Faculdade de Ciencias e Tecnologia (FCT) - Universidade Nova de Lisboa, were characterized in order to develop biocompatible wound dressing materials. The similar result is shown in term of the ratio of chitin:glucan, which is 1:1.72 for CGC-FCT and 1:1.69 for CGC-Commercial. For the analysis of metal element content, water and inorganic salts content and protein content, both polymers showed some discrepancies, where the content in CGC-FCT is always higher compared to the commercial one. The different characterization results between CGC-FCT and CGC-Commercial could be addressed to differences in the purification method, and the difference of its original strain yeast, whereas CGC-FCT is derived from P.pastoris and the commercial CGC is from A.niger. This work also investigated the effect of biopolymers, temperature dissolution, non-solvent composition on the characteristics of generated polymeric structure with biocompatible ionic liquid. The films were prepared by casting a polymer mixture, immersion in a non-solvent, followed by drying at ambient temperature. Three different non-solvents were tested in phase inversion method, i.e. water, methanol, and glycerol. The results indicate that the composition of non-solvent in the coagulation bath has great influence in generated polymeric structure. Water was found to be the best coagulant for producing a CGC polymeric film structure. The characterizations that have been done include the analysis of viscosity and viscoelasticity measurement, as well as sugar composition in the membrane and total sugar that was released during the phase inversion method. The rheology test showed that both polymer mixtures exhibit a non- Newtonian shear thinning behaviour. Where the viscosity and viscoelasticity test reveal that CGCFCT mixture has a typical behaviour of a viscous solution with entangled polymer chains and CGCCommercial mixture has true gel behaviour. The experimental results show us that the generated CGC solution from choline acetate could be used to develop both polymeric film structure and gel. The generated structures are thermally stable at 100° C, and are hydrophilic. The produced films have dense structure and mechanical stabilities against puncture up to 60 kPa.
Resumo:
Three different treatments were applied on several specimens of dolomitic and calcitic marble, properly stained with rust to mimic real situations (the stone specimens were exposed to the natural environment for about six months in contact with rusted iron). Thirty six marble specimens, eighteen calcitic and eighteen dolomitic, were characterized before and after treatment and monitored throughout the cleaning tests. The specimens were characterized by SEM-EDS (Scanning Electron Microscopy coupled with Energy Dispersion System), XRD (XRay Diffraction), XRF (X-Ray Fluorescence), FTIR (Fourier Transform Infrared Spectroscopy) and color measurements. It was also made a microscopic and macroscopic analysis of the stone surface along with the tests of short and long term capillary absorption. A series of test trials were conducted in order to understand which concentrations and contact times best suits to this purpose, to confirm what had been written to date in the literature. We sought to develop new methods of treatment application, skipping the usual methods of applying chemical treatments on stone substrates, with the use of cellulose poultice, resorting to the agar, a gel already used in many other areas, being something new in this area, which possesses great applicability in the field of conservation of stone materials. After the application of the best methodology for cleaning, specimens were characterized again in order to understand which treatment was more effective and less harmful, both for the operator and the stone material. Very briefly conclusions were that for a very intense and deep penetration into the stone, a solution of 3.5% of SDT buffered with ammonium carbonate to pH around 7 applied with agar support would be indicated. For rust stains in its initial state, the use of Ammonium citrate at a concentration of 5% buffered with ammonium to pH 7 could be applied more than once until satisfactory results appear.
Resumo:
Analytical, numerical and experimental models have been developed over time to try to characterize and understand the metal cutting process by chip removal. A true knowledge of the cutting process by chip removal is required by the increasing production, by the quality requirements of the product and by the reduced production time, in the industries in which it is employed. In this thesis an experimental setup is developed to evaluate the forces and the temperature distribution in the tool according to the orthogonal cutting model conditions, in order to evaluate its performance and its possible adoption in future works. The experimental setup is developed in a CNC lathe and uses an orthogonal cutting configuration, in which thin discs fixed onto a mandrel are cut by the cutting insert. In this experimental setup, the forces are measured by a piezoelectric dynamometer while temperatures are measured by thermocouples placed juxtaposed to the side face of the cutting insert. Three different solutions are implemented and evaluated for the thermocouples attachment in the cutting insert: thermocouples embedded in thermal paste, thermocouples embedded in copper plate and thermocouples brazed in the cutting insert. From the tests performed in the experimental setup it is concluded that the adopted forces measurement technique shows a good performance. Regarding to the adopted temperatures measurement techniques, only the thermocouples brazed in the cutting insert solution shows a good performance for temperature measurement. The remaining solutions show contact problems between the thermocouple and the side face of the cutting insert, especially when the vibration phenomenon intensifies during the cut. It is concluded that the experimental setup does not present a sufficiently robust and reliable performance, and that it can only be used in future work after making improvements in the assembly of the thermocouples.