6 resultados para Boiling heat transfer
Resumo:
This thesis is a study of how heat is transported in non-steady-state conditions from a superconducting Rutherford cable to a bath of superfluid helium (He II). The same type of superconducting cable is used in the dipole magnets of the Large Hadron Collider (LHC). The dipole magnets of the LHC are immersed in a bath of He II at 1.9 K. At this temperature helium has an extremely high thermal conductivity. During operation, heat needs to be efficiently extracted from the dipole magnets to keep their superconducting state. The thermal stability of the magnets is crucial for the operation of the LHC, therefore it is necessary to understand how heat is transported from the superconducting cables to the He II bath. In He II the heat transfer can be described by the Landau regime or by the Gorter-Mellink regime, depending on the heat flux. In this thesis both measurements and numerical simulation have been performed to study the heat transfer in the two regimes. A temperature increase of 8 2 mK of the superconducting cables was successfully measured experimentally. A new numerical model that covers the two heat transfer regimes has been developed. The numerical model has been validated by comparison with existing experimental data. A comparison is made between the measurements and the numerical results obtained with the developed model.
Resumo:
Dissertation to obtain the Doctoral degree in Physics Engineering
Resumo:
Construction and Building Materials 49 (2013), 315-327
Resumo:
Dissertation to obtain the degree of Doctor of Philosophy in Biomedical Engineering
Resumo:
The continued economic and population development puts additional pressure on the already scarce energetic sources. Thus there is a growing urge to adopt a sustainable plan able to meet the present and future energetic demands. Since the last two decades, solar trough technology has been demonstrating to be a reliable alternative to fossil fuels. Currently, the trough industry seeks, by optimizing energy conversion, to drive the cost of electricity down and therefore to place itself as main player in the next energetic age. One of the issues that lately have gained considerable relevance came from the observation of significant heat losses in a large number of receiver modules. These heat losses were attributed to slow permeation of traces of hydrogen gas through the steel tube wall into the vacuum annulus. The presence of hydrogen gas in the absorber tube results from the decomposition of heat transfer fluid due to the long-term exposure to 400°C. The permeated hydrogen acts as heat conduction mean leading to a decrease in the receivers performance and thus its lifetime. In order to prevent hydrogen accumulation, it has been common practice to incorporate hydrogen getters in the vacuum annulus of the receivers. Nevertheless these materials are not only expensive but their gas absorbing capacity can be insufficient to assure the required level of vacuum for the receivers to function. In this work the building of a permeation measurement device, vulnerabilities detected in the construction process and its overcome are described. Furthermore an experimental procedure was optimized and the obtained permeability results, of different samples were evaluated. The data was compared to measurements performed by an external entity. The reliability of the comparative data was also addressed. In the end conclusions on the permeability results for the different samples characteristics, feasibility of the measurement device are drawn and recommendations on future line of work were made.
Resumo:
With the increasing importance given to building rehabilitation comes the need to create simple, fast and non-destructive testing methods (NDT) to identify problems and for anomaly diagnosis. Ceramic tiles are one of the most typical kinds of exterior wall cladding in several countries; the earliest known examples are Egyptian dating from 4000 BC. This type of building facade coating, though being quite often used in due to its aesthetic and architectural characteristics, is one of the most complex that can be applied given the several parts from which it is composed; hence, it is also one of the most difficult to correctly diagnose with expeditious methods. The detachment of ceramic wall tiles is probably the most common and difficult to identify anomaly associated with this kind of cladding and it is also definitely the one that can compromise security the most. Thus, it is necessary to study a process of inspection more efficient and economic than the currently used which often consist in semi-destructive methods (the most common is the pull off test), that can only be used in a small part of the building at a time, allowing some assumptions of what can the rest of the cladding be like. Infrared thermography (IRT) is a NDT with a wide variety of applications in building inspection that is becoming commonly used to identify anomalies related with thermal variations in the inspected surfaces. Few authors have studied the application of IRT in anomalies associated with ceramic claddings claiming that the presence of air or water beneath the superficial layer will influence the heat transfer in a way that can be detected in both a qualitative and a quantitative way by the thermal camera, providing information about the state of the wall in a much broad area per trial than other methods commonly used nowadays. This article intends to present a review of the state of art of this NDT and its potentiality in becoming a more efficient way to diagnose anomalies in ceramic wall claddings.