9 resultados para Apparent and partial molar volume


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A Work Project, presented as part of the requirements for the Award of a Masters Degree in Management from the NOVA – School of Business and Economics

Relevância:

100.00% 100.00%

Publicador:

Resumo:

International Journal of Systematic and Evolutionary Microbiology, 60

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Thesis dissertation presented to obtain a PhD degree in Biochemistry at Instituto de Tecnologia Química e Biológica, Universidade Nova de Lisboa

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Acta Crystallographica Section F Structural Biology and Crystallization Communications Volume 65, Part 8

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia Informática

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Due to the importance and wide applications of the DNA analysis, there is a need to make genetic analysis more available and more affordable. As such, the aim of this PhD thesis is to optimize a colorimetric DNA biosensor based on gold nanoprobes developed in CEMOP by reducing its price and the needed volume of solution without compromising the device sensitivity and reliability, towards the point of care use. Firstly, the price of the biosensor was decreased by replacing the silicon photodetector by a low cost, solution processed TiO2 photodetector. To further reduce the photodetector price, a novel fabrication method was developed: a cost-effective inkjet printing technology that enabled to increase TiO2 surface area. Secondly, the DNA biosensor was optimized by means of microfluidics that offer advantages of miniaturization, much lower sample/reagents consumption, enhanced system performance and functionality by integrating different components. In the developed microfluidic platform, the optical path length was extended by detecting along the channel and the light was transmitted by optical fibres enabling to guide the light very close to the analysed solution. Microfluidic chip of high aspect ratio (~13), smooth and nearly vertical sidewalls was fabricated in PDMS using a SU-8 mould for patterning. The platform coupled to the gold nanoprobe assay enabled detection of Mycobacterium tuberculosis using 3 8l on DNA solution, i.e. 20 times less than in the previous state-of-the-art. Subsequently, the bio-microfluidic platform was optimized in terms of cost, electrical signal processing and sensitivity to colour variation, yielding 160% improvement of colorimetric AuNPs analysis. Planar microlenses were incorporated to converge light into the sample and then to the output fibre core increasing 6 times the signal-to-losses ratio. The optimized platform enabled detection of single nucleotide polymorphism related with obesity risk (FTO) using target DNA concentration below the limit of detection of the conventionally used microplate reader (i.e. 15 ng/μl) with 10 times lower solution volume (3 μl). The combination of the unique optical properties of gold nanoprobes with microfluidic platform resulted in sensitive and accurate sensor for single nucleotide polymorphism detection operating using small volumes of solutions and without the need for substrate functionalization or sophisticated instrumentation. Simultaneously, to enable on chip reagents mixing, a PDMS micromixer was developed and optimized for the highest efficiency, low pressure drop and short mixing length. The optimized device shows 80% of mixing efficiency at Re = 0.1 in 2.5 mm long mixer with the pressure drop of 6 Pa, satisfying requirements for the application in the microfluidic platform for DNA analysis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

RESUMO: Introdução: A obstrução da via aérea central (OVAC) refere-se a um processo patológico que conduz a limitação do fluxo de ar ao nível do espaço glótico e subglótico, traqueia e brônquios principais. O seu correcto diagnóstico e tratamento constituem um território de interesse e preocupação para os profissionais de saúde, e requerem um profundo conhecimento da sua etiologia, fisiologia, diagnóstico e opções terapêuticas dado o potencial em originar significativa morbilidade e mortalidade. A avaliação da OVAC abrange múltiplas vertentes, entre as quais se salienta o componente clínico (sinais e sintomas), a repercussão fisiopatológica (função respiratória) e o estudo imagiológico (TC do tórax e broncoscopia). A compilação destes dados associada à etiologia, constituem factores importantes para estabelecer o prognóstico, determinar a necessidade de tratamento ou delinear uma futura intervenção terapêutica. A broncoscopia é o Gold Standard de avaliação desta condição, mas desde há cerca de 40 anos a curva de débito-volume constitui uma ferramenta não invasiva de detecção de OVAC. Apesar deste método ser utilizado até os nossos dias, poucos têm sido os estudos com o objectivo de verificar a sensibilidade e especificidade da curva de débito-volume na detecção de OVAC, bem como averiguar a relação entre as alterações morfológicas e quantitativas da mesma com a localização, o tipo e o grau da obstrução. Material e Métodos: Entre 1 de Novembro de 2009 e 30 de Abril de 2010, os doentes com indicação para a realização de broncoscopia diagnóstica ou terapêutica na Unidade de Técnicas Invasivas Pneumológicas (UTIP) do Centro Hospitalar Lisboa Norte – Hospital Pulido Valente (CHLN – HPV) foram seleccionados de forma consecutiva de acordo com os critérios de inclusão e exclusão. As avaliações (broncoscopia, curva de débito-volume e avaliação da dispneia) realizaram-se com um intervalo de tempo máximo de sete dias. A broncoscopia flexível foi realizada segundo as normas da British Thoracic Society e as curvas de débito-volume segundo as normas da ATS/ERS TaskForce 2005. Para a avaliação da dispneia recorreu-se à escala de dispneia MRC (Medical Research Council). Um painel de peritos realizou a avaliação da morfologia da curva de débito-volume (sugestiva ou não de OVAC) e um elemento independente a verificação dos critérios quantitativos e morfológicos (variáveis intra e extratorácica e fixa) da curva. O estudo foi aprovado pela Comissão de Ética para a Saúde do CHLN e todos os doentes assinaram um consentimento informado de participação. Resultados: Estudaram-se 82 doentes, 36 (44%) dos quais com OVAC. A predominância foi do género masculino, em relação ao feminino. A sensibilidade e especificidade dos critérios quantitativos da curva de débito-volume na detecção de OVAC foi de 91.3% e 88.9% respectivamente. Quando se utilizaram os critérios morfológicos da curva de débito-volume os valores foram de 93.5% e 30.6%. A agregação dos critérios morfológicos e quantitativos permitiu alcançar uma sensibilidade de 95.7% e especificidade de 86.1%. Nesta amostra, o critério quantitativo com maior ocorrência foi o FEF50/FIF50≥1 (83% dos doentes com OVAC). Este mostrou relacionar-se com todas as localizações de obstrução excepto o terço médio da traqueia. Mostrou, ainda, ter uma relação forte e positiva com o grau e tipo de obstrução (intra e extraluminal). O segundo foi o FEV1/PEF≥8, presente em 36% dos casos de OVAC. Relacionou-se com as obstruções no terço inferior da traqueia e brônquio principal direito (BPD). Também apresentou relação forte e positiva com o grau de obstrução e com os tipos de obstrução anteriormente descritos. Quanto à sintomatologia foi possível associar o grau de obstrução com o de dispneia e a presença de estridor com o grau e localização da obstrução na traqueia. Conclusões: Os resultados deste estudo demonstram que os critérios quantitativos da curva de débito-volume têm elevada sensibilidade e especificidade na detecção de OVAC. O critério FEV50/FIF50≥1 tem um bom poder discriminativo na detecção dessa condição, tendo sido relacionado com a localização, o grau e o tipo de obstrução. O critério FEV1/PEF≥8, embora com menor poder discriminativo, também se relaciona com o grau, a localização e o tipo de obstrução. A morfologia da curva tem uma boa sensibilidade mas baixa especificidade na detecção de OVAC, mas a agregação entre os critérios morfológicos e quantitativos aumenta a sensibilidade e especificidade. A dispneia e o estridor foram relacionados com o grau de obstrução e o último com a localização ao nível da traqueia.-------------ABSTRACT: Introduction: Central airway obstruction (CAO) refers to a pathological process that leads to restriction of airflow at the level of the glottis and subglottis, trachea and main bronchi. It’s proper diagnosis and treatment is an area of interest and concern to health professionals, and requires a deep knowledge of its etiology, physiology, diagnosis and treatment options, concerning the potential to cause significant morbidity and mortality. The evaluation of CAO covers multiple aspects: the clinical component (signs and symptoms), the pathophysiological effect (lung function) and the imaging study (bronchoscopy and chest CT). The compilation of this data associated with the etiology, are important for establishing prognosis, determine the need for treatment or outline a future therapeutic intervention. Bronchoscopy is the gold standard for evaluating this condition, but for the last 40 years the flow-volume loop has been used as a noninvasive tool for detecting CAO. Although this method is still in use, only few studies were made in order to verify its sensitivity and specificity in detecting CAO, and investigate the relation between morphological and quantitative changes of the curve to location, type and degree of obstruction. Methods: Between 1st November 2009 and 30th April 2010, patients with indication to perform diagnostic or therapeutic bronchoscopy in Interventional Pulmonology Unit - Hospital Pulido Valente (CHLN - HPV), were selected consecutively according to the inclusion and exclusion criteria. All assessments (bronchoscopy, flow-volume loop and dyspnea) were carried out within a period of seven days. The flexible bronchoscopy was performed according to the standards of the British Thoracic Society and the flow-volume loops in accordance with the standards of the ATS / ERS Taskforce 2005. For the evaluation of dyspnea was used to MRC dyspnea scale (Medical Research Council). A panel of experts evaluated the morphology of flow-volume loop (suggestive or non-suggestive of CAO) and an independent element established the quantitative criteria and morphological (intra and extrathoracic variables and fixed) of the curve. This study was approved by the Ethics Committee for Health CHLN and all the patients signed an informed consent to participate. Results: We’ve studied 82 patients, 36 (44%) of those with CAO. The majority of the patients were males, compared to females. The sensitivity and specificity of the quantitative criteria of the flow-volume curve in detecting CAO was 91.3% and 88.9% respectively. When we used the morphological criteria of flow-volume loop these values were 93.5% and 30.6%. The combination of quantitative and morphological criteria produced values of 95.7% sensitivity and 86.1% specificity. FEF50/FIF50≥1 was the most representative quantitative criterion (83% of patients with CAO) and it was correlated with all sites of obstruction except in the middle third of the trachea. It has shown a strong and positive association with the degree and type of obstruction (intra and extraluminal). The second was the FEV1/PEF ≥ 8, present in 36% of cases of CAO. It could be correlated with the obstruction in the lower third of the trachea and right main bronchus. It also showed a strong positive relation with the degree and types of obstruction described above. Regarding symptoms, we found a link between the degree of obstruction and dyspnea. The presence of stridor was correlated with the location and the degree of obstruction in the trachea. Conclusion: The results of this study demonstrate that the quantitative criteria of the flow-volume loop have a high sensitivity and specificity in detecting CAO. The criterion FEV50/FIF50 ≥ 1 has a good discriminative power to detect this condition and was related to the location, degree and type of obstruction. The criterion FEV1/PEF ≥ 8, although with a weaker discriminative power, also relates to the degree, location and type of obstruction. The morphology of the curve has a good sensitivity but low specificity in detecting CAO although the combination between the morphological and quantitative criteria increases sensitivity and specificity. Dyspnea and stridor were related to the degree of obstruction and the last one with its location in the trachea.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Taking a Media Anthropology’s approach to dynamics of mediated selfrepresentation in migratory contexts, this thesis starts by mapping radio initiatives produced by, for and/or with migrants in Portugal. To further explore dynamics of support of initial settlement in the country, community-making, cultural reproduction, and transnational connectivity - found both in the mapping stage and the minority media literature (e.g. Kosnick, 2007; Rigoni & Saitta, 2012; Silverstone & Georgiou, 2005) - a case study was selected: the station awarded with the first bilingual license in Portugal. The station in question caters largely to the British population presenting themselves as “expats” and residing in the Algarve. The ethnographic strategy to research it consisted of “following the radio” (Marcus, 1995) beyond the station and into the events and establishments it announces on air, so as to relate production and consumption realms. The leading research question asks how does locally produced radio play into “expats” processes of management of cultural identity – and what are the specificities of its role? Drawing on conceptualizations of lifestyle migration (Benson & O’Reilly, 2009), production of locality (Appadurai 1996) and the public sphere (Butsch, 2007; Calhoun & et al, 1992; Dahlgren, 2006), this thesis contributes to valuing radio as a productive gateway to research migrants’ construction of belonging, to inscribe a counterpoint in the field of minority media, and to debate conceptualizations of migratory categories and flows. Specifically, this thesis argues that the station fulfills similar roles to other minority radio initiatives but in ways that are specific to the population being catered to. Namely, unlike other minority stations, radio facilitates the process of transitioning between categories along on a continuum linking tourists and migrants. It also reflects and participates in strategies of reterritorialization that rest on functional and partial modes of incorporation. While contributing to sustain a translocality (Appadurai, 1996) it indexes and fosters a stance of connection that is symbolically and materially connected to the UK and other “neighborhoods” but is, simultaneously, oriented to engaging with the Algarve as “home”. Yet, besides reifying a British cultural identity, radio’s oral, repetitive and ephemeral discourse particularly trivializes the reproduction of an ambivalent stance of connection with place that is shared by other “expats”. This dynamic is related to migratory projects driven by social imaginaries fostered by international media that stimulate the search for idealized ways of living, which the radio associates with the Algarve. While recurrently localizing and validating the narrative projecting an idealized “good life”, radio amplifies dynamics among migrants that seem to reaffirm the migratory move as a good choice.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Release of chloroethene compounds into the environment often results in groundwater contamination, which puts people at risk of exposure by drinking contaminated water. cDCE (cis-1,2-dichloroethene) accumulation on subsurface environments is a common environmental problem due to stagnation and partial degradation of other precursor chloroethene species. Polaromonas sp. strain JS666 apparently requires no exotic growth factors to be used as a bioaugmentation agent for aerobic cDCE degradation. Although being the only suitable microorganism found capable of such, further studies are needed for improving the intrinsic bioremediation rates and fully comprehend the metabolic processes involved. In order to do so, a metabolic model, iJS666, was reconstructed from genome annotation and available bibliographic data. FVA (Flux Variability Analysis) and FBA (Flux Balance Analysis) techniques were used to satisfactory validate the predictive capabilities of the iJS666 model. The iJS666 model was able to predict biomass growth for different previously tested conditions, allowed to design key experiments which should be done for further model improvement and, also, produced viable predictions for the use of biostimulant metabolites in the cDCE biodegradation.