7 resultados para Ammonia.


Relevância:

10.00% 10.00%

Publicador:

Resumo:

XVIII Jornadas de Paleontología, 2002

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Thesis for the Degree of Master of Science in Biotechnology Universidade Nova de Lisboa, Faculdade de Ciências e Tecnologia

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Hindawi Publishing Corporation Bioinorganic Chemistry and Applications Volume 2010, Article ID 634597, 8 pages

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia do ambiente, perfil de engenharia sanitária

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The main objective of this thesis is to study the developing fields of aquaponics and its potential for aquaculture wastewater treatment and human urine treatment. Aquaponics is a food production system which combines fish farming (aquaculture) with soilless crop farming (hydroponics). In this thesis the concept of aquaponics and the underlying processes are explained. Research on aquaculture wastewater and human urine wastewater is reviewed and its potential application with aquaponic systems is studied. An overview of the different types of aquaponic systems and current research on the field is also presented. A case study was conducted in a farm in Askeröd, Sweden, which involved building two aquaponic systems (System 1 and System 2) and a human urine-based aquaponic system (System 3), with different degrees of component complexity and sizes. The design, building and monitoring of System 1, System 2 and System 3 was documented and described in detail. Four day experiments were conducted which tested the evolution in concentration of Total Ammonia Nitrogen (NH4+/NH3), Nitrite (NO2-), Nitrate (NO3-), Phosphate (PO43-), and Dissolved Oxygen (O2) after an initial nutrient input. The goal was to assess the concentrations of these parameters after four days and compare them with relevant literature examples in the aquaculture industry and in source-separated urine research. Neither of the two aquaponic systems (System 1 and System 2) displayed all of the parameter concentrations in the last day of testing below reference values found in literature. The best performing of the aquaponic systems was the more complex system (System 2) combining the hydroponic Nutrient Film Technique with a Deep Water Culture component, with a Total Ammonia Nitrogen concentration of 0,20 mg/L, a Nitrite concentration of 0,05 mg/L, a Nitrate concentration of 1,00-5,00 mg/L, a Phosphate concentration of <0,02 mg/L and a Dissolved Oxygen concentration of 8,00 mg/L. The human urine-based aquaponic system (System 3) underperformed in achieving the reference concentration values in literature for most parameters. The removal percentage between the higher recorded values after the input addition and the final day of testing was calculated for two literature examples of separated urine treatment and System 3. The system had a removal percentage of 75% for Total Ammonia Nitrogen, 98% for Nitrite, 25% for Nitrate and 50% for Phosphate. These percentages still underperformed literature examples in most of the tested parameters. The results gathered allowed to conclude that while aquaculture wastewater treatment and human urine treatment is possible with aquaponics systems, overall these did not perform as well as some examples found in recirculating aquaculture systems and source-separated urine treatment literature. However, better measuring techniques, longer testing periods and more research is recommended in this field in order to draw an improved representative conclusion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Water is a limited resource for which demand is growing. Contaminated water from inadequate wastewater treatment provides one of the greatest health challenges as it restricts development and increases poverty in emerging and developing countries. Therefore, the connection between wastewater and human health is linked to access to sanitation and to human waste disposal. Adequate sanitation is expected to create a barrier between disposed human excreta and sources of drinking water. Different approaches to wastewater management are required for different geographical regions and different stages of economic governance depending on the capacity to manage wastewater. Effective wastewater management can contribute to overcome the challenges of water scarcity. Separate collection of human urine at its source is one promising approach that strongly reduces the economic and load demands on wastewater treatment plants (WWTP). Treatment of source-separated urine appears as a sanitation system that is affordable, produces a valuable fertiliser, reduces pollution of water resources and promotes health. However, the technical realisation of urine separation still faces challenges. Biological hydrolysis of urea causes a strong increase of ammonia and pH. Under these conditions ammonia volatilises which can cause odour problems and significant nitrogen losses. The above problems can be avoided by urine stabilisation. Biological nitrification is a suitable process for stabilisation of urine. Urine is a highly concentrated nutrient solution which can lead to strong inhibition effects during bacterial nitrification. This can further lead to process instabilities. The major cause of instability is accumulation of the inhibitory intermediate compound nitrite, which could lead to process breakdown. Enhanced on-line nitrite monitoring can be applied in biological source-separated urine nitrification reactors as a sustainable and efficient way to improve the reactor performance, avoiding reactor failures and eventual loss of biological activity. Spectrophotometry appears as a promising candidate for the development and application of on-line nitrite monitoring. Spectroscopic methods together with chemometrics are presented in this work as a powerful tool for estimation of nitrite concentrations. Principal component regression (PCR) is applied for the estimation of nitrite concentrations using an immersible UV sensor and off-line spectra acquisition. The effect of particles and the effect of saturation, respectively, on the UV absorbance spectra are investigated. The analysis allows to conclude that (i) saturation has a substantial effect on nitrite estimation; (ii) particles appear to have less impact on nitrite estimation. In addition, improper mixing together with instabilities in the urine nitrification process appears to significantly reduce the performance of the estimation model.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In order to address and resolve the wastewater contamination problem of the Sines refinery with the main objective of optimizing the quality of this stream and reducing the costs charged to the refinery, a dynamic mass balance was developed nd implemented for ammonia and polar oil and grease (O&G) contamination in the wastewater circuit. The inadequate routing of sour gas from the sour water stripping unit and the kerosene caustic washing unit, were identified respectively as the major source of ammonia and polar substances present in the industrial wastewater effluent. For the O&G content, a predictive model was developed for the kerosene caustic washing unit, following the Projection to Latent Structures (PLS) approach. Comparison between analytical data for ammonia and polar O&G concentrations in refinery wastewater originating from the Dissolved Air Flotation (DAF) effluent and the model predictions of the dynamic mass balance calculations are in a very good agreement and highlights the dominant impact of the identified streams for the wastewater contamination levels. The ammonia contamination problem was solved by rerouting the sour gas through an existing clogged line with ammonia salts due to a non-insulated line section, while for the O&G a dynamic mass balance was implemented as an online tool, which allows for prevision of possible contamination situations and taking the required preventive actions, and can also serve as a basis for establishing relationships between the O&G contamination in the refinery wastewater with the properties of the refined crude oils and the process operating conditions. The PLS model developed could be of great asset in both optimizing the existing and designing new refinery wastewater treatment units or reuse schemes. In order to find a possible treatment solution for the spent caustic problem, an on-site pilot plant experiments for NaOH recovery from the refinery kerosene caustic washing unit effluent using an alkaline-resistant nanofiltration (NF) polymeric membrane were performed in order to evaluate its applicability for treating these highly alkaline and contaminated streams. For a constant operating pressure and temperature and adequate operating conditions, 99.9% of oil and grease rejection and 97.7% of chemical oxygen demand (COD) rejection were observed. No noticeable membrane fouling or flux decrease were registered until a volume concentration factor of 3. These results allow for NF permeate reuse instead of fresh caustic and for significant reduction of the wastewater contamination, which can result in savings of 1.5 M€ per year at the current prices for the largest Portuguese oil refinery. The capital investments needed for implementation of the required NF membrane system are less than 10% of those associated with the traditional wet air oxidation solution of the spent caustic problem. The operating costs are very similar, but can be less than half if reusing the NF concentrate in refinery pH control applications. The payback period was estimated to be 1.1 years. Overall, the pilot plant experimental results obtained and the process economic evaluation data indicate a very competitive solution through the proposed NF treatment process, which represents a highly promising alternative to conventional and existing spent caustic treatment units.