15 resultados para Air Quality Control Systems
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia do Ambiente Perfil de Engenharia de Sistemas Ambientais
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Engenharia Informática
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia do Ambiente Perfil Gestão de Sistemas Ambientais
Resumo:
Leadership and Management in Engineering, January 2009
Resumo:
The capacity to use geologic materials (soil and rock) that are available in the surrounding environment is inherent to the human civilization and has contributed to the evolution of societies throughout the course of history. The use of these materials in the construction of structures such as houses, roads, railways or dams, stirred the improvement of socioeconomic and environmental conditions. Several reports of structural problems on embankments can be found throughout history. A considerable number of those registers can be linked to inadequate compaction, demonstrating the importance of guaranteeing a suitable quality of soil compaction. Various methodologies and specifications of compaction quality control on site of earthworks, based on the fill moisture content and dry unit weight, were developed during the 20th century. Two widely known methodologies are the conventional and nuclear techniques. The conventional methods are based on the use of the field sand cone test (or similar) and sampling of material for laboratory-based testing to evaluate the fill dry unit weight and water content. The nuclear techniques measure both parameters in the field using a nuclear density gauge. A topic under discussion in the geotechnical community, namely in Portugal, is the comparison between the accuracy of the nuclear gauge and sand cone test results for assessing the compaction and density ratio of earth fills, particularly for dams. The main purpose of this dissertation is to compare both of them. The data used were acquired during the compaction quality control operations at the Coutada/Tamujais dam trial embankment and core construction. This is a 25 m high earth dam located in Vila Velha de Rodão, Portugal. To analyse the spatial distribution of the compaction parameters (water content and compaction ratio), a 3D model was also developed. The main results achieved are discussed and finally some considerations are put forward on the suitability of both techniques to ensure fill compaction quality and on additional research to complement the conclusions obtained.
Resumo:
A Work Project, presented as part of the requirements for the Award of a Masters Degree in Management from the NOVA – School of Business and Economics
Resumo:
The study of Quality of Life (Qol) has been conducted on various scales throughout the years with focus on assessing overall quality of living amongst citizens. The main focus in these studies have been on economic factors, with the purpose of creating a Quality of Life Index (QLI).When it comes down to narrowing the focus to the environment and factors like Urban Green Spaces (UGS) and air quality the topic gets more focused on pointing out how each alternative meets this certain criteria. With the benefits of UGS and a healthy environment in focus a new Environmental Quality of Life Index (EQLI) will be proposed by incorporating Multi Criteria Analysis (MCA) and Geographical Information Systems (GIS). Working with MCA on complex environmental problems and incorporating it with GIS is a challenging but rewarding task, and has proven to be an efficient approach among environmental scientists. Background information on three MCA methods will be shown: Analytical Hierarchy Process (AHP), Regime Analysis and PROMETHEE. A survey based on a previous study conducted on the status of UGS within European cities was sent to 18 municipalities in the study area. The survey consists of evaluating the current status of UGS as well as planning and management of UGS with in municipalities for the purpose of getting criteria material for the selected MCA method. The current situation of UGS is assessed with use of GIS software and change detection is done on a 10 year period using NDVI index for comparison purposes to one of the criteria in the MCA. To add to the criteria, interpolation of nitrogen dioxide levels was performed with ordinary kriging and the results transformed into indicator values. The final outcome is an EQLI map with indicators of environmentally attractive municipalities with ranking based on predefinedMCA criteria using PROMETHEE I pairwise comparison and PROMETHEE II complete ranking of alternatives. The proposed methodology is applied to Lisbon’s Metropolitan Area, Portugal.
Resumo:
Trabalho apresentado no âmbito do Mestrado em Engenharia Informática, como requisito parcial para obtenção do grau de Mestre em Engenharia Informática
Resumo:
RESUMO Tratando-se a asma de uma doença respiratória, desde há várias décadas que tem sido abordada a hipótese de que factores ambientais, nomeadamente os relacionados com a qualidade do ar inalado, possam contribuir para o seu agravamento. Para além dos aeroalergenos, outros factores ambientais como a poluição atmosférica estarão associados às doenças respiratórias. O ar respirado contém uma variedade de poluentes atmosféricos, provenientes quer de fontes naturais quer de origem antropogénica, nomeadamente de actividades industriais, domésticas ou das emissões de veículos. Estes poluentes, tradicionalmente considerados como um problema de foro ambiental, têm sido cada vez mais encarados como um problema de saúde pública. Também a qualidade do ar interior, tem sido associada a queixas respiratórias, não só em termos ocupacionais mas também em exposições domésticas. Dentro dos principais poluentes, encontramos a matéria particulada (como as PM10), o O3, NO2, e os compostos orgânicos voláteis (COVs). Se é verdade que os três primeiros têm como principais fontes de exposição a combustão fóssil associada aos veículos automóveis, já os COVs (como o benzeno, tolueno, xileno, etilbenzeno e formaldeído) são poluentes mais característicos do ar interior. Os mecanismos fisiopatológicos subjacentes à agressão dos poluentes do ar não se encontram convenientemente esclarecidos. Pensa-se que após a sua inalação, induzam um grau crescente de stress oxidativo que será responsável pelo desenvolvimento da inflamação das vias aéreas. A progressão do stress oxidativo e da inflamação, associarse- ão posteriormente a lesão local (pulmonar) e sistémica. Neste trabalho pretendeu-se avaliar os efeitos da exposição individual a diversos poluentes, do ar exterior e interior, sobre as vias aéreas, recorrendo a parâmetros funcionais, inflamatórios e do estudo do stress oxidativo. Neste sentido, desenvolveu-se um estudo de painel na cidade de Viseu, em que foram acompanhadas durante 18 meses, 51 crianças com história de sibilância, identificadas pelo questionário do estudo ISAAC. As crianças foram avaliadas em quatro Visitas (quatro medidas repetidas), através de diversos exames, que incluíram execução de espirometria com broncodilatação, medição ambulatória do PEF, medição de FENO e estudo do pH no condensado brônquico do ar exalado. O estudo dos 8-isoprostanos no condensado brônquico foi efectuado somente em duas Visitas, e o do doseamento de malonaldeído urinário somente na última Visita. Para além da avaliação do grau de infestação de ácaros do pó do colchão, para cada criança foi calculado o valor de exposição individual a PM10, O3, NO2, benzeno, tolueno, xileno, etilbenzeno e formaldeído, através de uma complexa metodologia que envolveu técnicas de modelação associadas a medições directas do ar interior (na casa e escola da criança) e do ar exterior. Para a análise de dados foram utilizadas equações de estimação generalizadas com uma matriz de correlação de trabalho uniforme, com excepção do estudo das associações entre poluentes, 8-isoprostanos e malonaldeído. Verificou-se na análise multivariável a existência de uma associação entre o agravamento dos parâmetros espirométricos e a exposição aumentada a PM10, NO2, benzeno, tolueno e etilbenzeno. Foram também encontradas associações entre diminuição do pH do EBC e exposição crescente a PM10, NO2, benzeno e etilbenzeno e associações entre valores aumentados de FENO e exposição a etilbenzeno e tolueno. O benzeno, o tolueno e o etilbenzeno foram associados com maior recurso a broncodilatador nos 6 meses anteriores à Visita e o tolueno com deslocações ao serviço de urgência. Os resultados dos modelos de regressão que incluíram o efeito do poluente ajustado para o grau de infestação de ácaros do pó foram, de uma forma geral, idênticos ao da análise multivariável anterior, com excepção das associações para com o FENO. Nos modelos de exposição com dois poluentes, com o FEV1 como variável resposta, somente o benzeno persistiu com significado estatístico. No modelo com dois poluentes tendo o pH do EBC como variável resposta, somente persistiram as PM10. Os 8-isoprostanos correlacionaram-se com alguns COVs, designadamente etilbenzeno, xileno, tolueno e benzeno. Os valores de malonaldeído urinário não se correlacionaram com os valores de poluentes. Verificou-se no entanto que de uma forma geral, e em particular mais uma vez para os COVs, as crianças mais expostas a poluentes, apresentaram valores superiores de malonaldeído na urina. Verificou-se que os poluentes do ar em geral, e os COVs em particular, se associaram com uma deterioração das vias aéreas. A exposição crescente a poluentes associou-se não só com obstrução brônquica, mas também com FENO aumentado e maior acidez das vias aéreas. A exposição crescente a COVs correlacionou-se com um maior stress oxidativo das vias aéreas (medido pelos 8-isoprostanos). As crianças com exposição superior a COVs apresentaram maiores valores de malonaldeído urinário. Este trabalho sugere uma associação entre exposição a poluentes, inflamação das vias aéreas e stress oxidativo. Vem reforçar o interesse dos poluentes do ar, nomeadamente os associados a ambientes interiores, frequentemente esquecidos e que poderão ser explicativos do agravamento duma criança com sibilância.-----------ABSTRACT: Asthma is a chronic respiratory disease that could be influenced by environmental factors, as allergens and air pollutants. The air breathed contains a diversity of air pollutants, both from natural or anthropogenic sources. Atmospheric pollution, traditionally considered an environmental problem, is nowadays looked as an important public health problem. Indoor air pollutants are also related with respiratory diseases, not only in terms of occupational exposures but also in domestic activities. Particulate matter (such as PM10), O3, NO2 and volatile organic compounds (VOCs) are the main air pollutants. The main source for PM10, O3, NO2 exposure is traffic exhaust while for VOCs (such as benzene, toluene, xylene, ethylbenzene and phormaldehyde) the main sources for exposure are located in indoor environments. The pathophysiologic mechanisms underlying the aggression of air pollutants are not properly understood. It is thought that after inhalation, air pollutants could induce oxidative stress, which would be responsible for airways inflammation. The progression of oxidative stress and airways inflammation, would contribute for the local and systemic effects of the air pollutants. The present study aimed to evaluate the effects of individual exposure to various pollutants over the airways, through lung function tests, inflammatory and oxidative stress biomarkers. In this sense, we developed a panel study in the city of Viseu, that included 51 children with a history of wheezing. Those children that were identified by the ISAAC questionnaire, were followed for 18 months. Children were assessed four times (four repeated measures) through the following tests: spirometry with bronchodilation test, PEF study, FENO evaluation and exhaled breath condensate pH measurement. 8-isoprostane in the exhaled breath condensate were also measured but only in two visits. Urinary malonaldehyde measurement was performed only in the last visit. Besides the assessment of the house dust mite infestation, we calculated for each child the value of individual exposure to a wide range of pollutants: PM10, O3, NO2, benzene, toluene, xylene, ethyl benzene and formaldehyde. This strategy used a complex methodology that included air pollution modelling techniques and direct measurements indoors (homes and schools) and outdoors. Generalized estimating equations with an exchangeable working correlation matrix were used for the analysis of the data. Exceptions were for the study of associations between air pollutants, malonaldehyde and 8-isoprostanes. In the multivariate analysis we found an association between worsening of spirometric outcomes and increased exposure to PM10, NO2, benzene, toluene and ethylbenzene. In the multivariate analysis we found also negative associations between EBC pH and exposure to PM10, NO2, benzene, ethylbenzene and positive associations between FENO and exposure to ethylbenzene and toluene. Benzene, toluene and ethylbenzene were associated with increased use of bronchodilator in the 6 months prior to the visit and toluene with emergency department visits. Results of the regression models that included also the effect of the pollutant adjusted for the degree of infestation to house dust mites, were identical to the previous models. Exceptions were for FENO associations. In the two-pollutant models, with the FEV1 as dependent variable, only benzene persisted with statistical significance. In the two pollutant model with pH of EBC as dependent variable, only PM10 persisted. 8-isoprostanes were well correlated with some VOCs, namely with ethylbenzene, xylene, toluene and benzene. Urinary malonaldehyde did not present any correlation with air pollutants exposure. However, those children more exposed to air pollutants (namely to VOCs), presented higher values of malonaldehyde. It was found that air pollutants in general, and namely VOCs, were associated with deterioration of the airways. The increased exposure to air pollutants was associated not only with airways obstruction, but also with increased FENO and higher acidity of the airways. The increased exposure to VOCs was correlated with increased airways oxidative stress (measured by 8-isoprostane). Children with higher levels of exposure to VOCs had higher values of urinary malonaldehyde. This study suggests a relation between air pollution, airways inflammation and oxidative stress. It suggests also that attention should be dedicated to air quality as air pollutants could cause airways deterioration.
Resumo:
ABSTRACT - The problem of how to support “intentions to make behavioural changes” (IBC) and “behaviour changes” (BC) in smoking cessation when there is a scarcity of resources is a pressing issue in public health terms. The present research focuses on the use of information and communications technologies and their role in smoking cessation. It is developed in Portugal after the ratification of WHO Framework Convention on Tobacco Control (on 8 November 2005). The prevalence of smokers over fifteen years of age within the population stood at 20.9% (30.9% for men and 11.8% for women). While the strategy of helping people to quit smoking has been emphasised at National Health Service (NHS) level, the uptake of cessation assistance has exceeded the capacity of the service. This induced the search of new theoretical and practical venues to offer alternative options to people willing to stop smoking. Among these, the National Health Plan (NHP) of Portugal (2004-2010), identifies the use of information technologies in smoking cessation. eHealth and the importance of health literacy as a means of empowering people to make behavioural changes is recurrently considered an option worth investigating. The overall objective of this research is to understand, in the Portuguese context, the use of the Internet to help people to stop smoking. Research questions consider factors that may contribute to “intentions to make behavioural changes” (IBC) and “behavioural changes” (BC) while using a Web-Assisted Tobacco Intervention Probe (WATIP). Also consideration is given to the trade-off on the use of the Web as a tool for smoking cessation: can it reach a vast number of people for a small cost (efficiency) demonstrating to work in the domain of smoking cessation (efficacy)”? In addition to the introduction, there is a second chapter in which the use of tobacco is discussed as a public health menace. The health gains achieved by stopping smoking and the means of quitting are also examined, as is the use of the Internet in smoking cessation. Then, several research issues are introduced. These include background theory and the theoretical framework for the Sense of Coherence. The research model is also discussed. A presentation of the methods, materials and of the Web-Assisted Tobacco Intervention Probe (WATIP) follows. In chapter four the results of the use of the Web-Assisted Tobacco Intervention Probe (WATIP) are presented. This study is divided into two sections. The first describes results related to quality control in relation to the Web-Assisted Tobacco Intervention Probe (WATIP) and gives an overview of its users. Of these, 3,150 answered initial eligibility questions. In the end, 1,463 met all eligibility requirements, completed intake, decided on a day to quit smoking (Dday) and declared their “intentions to make behavioural changes” (IBC) while a second targeted group of 650 did not decide on a Dday. With two quit attempts made before joining the platform, most of the participants had experienced past failures while wanting to stop. The smoking rate averaged 21 cigarettes per day. With a mean age of 35, of the participants 55% were males. Among several other considerations, gender and the Sense of Coherence (SOC) influenced the success of participants in their IBC and endeavour to set quit dates. The results of comparing males and females showed that, for current smokers, establishing a Dday was related to gender differences, not favouring males (OR=0.76, p<0.005). Belonging to higher Socio-economic strata (SES) was associated with the intention to consider IBC (when compared to lower SES condition) (OR=1.57, p<0.001) and higher number of school years (OR=0.70, p<0.005) favoured the decision to smoking cessation. Those who demonstrated higher confidence in their likelihood of success in stopping in the shortest time had a higher rate of setting a Dday (OR=0.51, p<0.001). There were differences between groups in IBC reflecting the high and low levels of the SOC score (OR=1.43, p=0.006), as those who considered setting a Dday had higher levels of SOC. After adjusting for all variables, stages of readiness to change and SOC were kept in the model. This is the first Arm of this research where the focus is a discussion of the system’s implications for the participants’ “intentions to make behavioural changes” (IBC). Moreover, a second section of this study (second Arm) offers input collected from 77 in-depth interviews with the Web-Assisted Tobacco Intervention Probe (WATIP) users. Here, “Behaviour Change” (BC) and the usability of the platform are explored a year after IBC was declared. A percentage of 32.9% of self-reported, 12-month quitters in continuous abstinence from smoking from Dday to the 12-month follow- up point of the use of the Web-Assisted Tobacco Intervention Probe (WATIP) has been assessed. Comparing the Sense of Coherence (SOC) scores of participants by their respective means, according to the two groups, there was a significant difference in these scores of non smokers (BC) (M=144,66, SD=22,52) and Sense of Coherence (SOC) of smokers (noBC) (M=131,51, SD=21,43) p=0.014. This WATIP strategy and its contents benefit from the strengthening of the smoker’s sense of coherence (SOC), so that the person’s progress towards a life without tobacco may be experienced as comprehensible, manageable and meaningful. In this sample the sense of coherence (SOC) effect is moderate although it is associated with the day to quit smoking (Dday). Some of the limitations of this research have to do with self-selection bias, sample size (power) and self-reporting (no biochemical validation). The enrolment of participants was therefore not representative of the smoking population. It is not possible to verify the Web-Assisted Tobacco Intervention Probe (WATIP) evaluation of external validity; consequently, the results obtained cannot be applied generalized. No participation bias is provided. Another limitation of this study is the associated limitations of interviews. Interviewees’ perception that fabricating answers could benefit them more than telling the simple truth in response to questions is a risk that is not evaluated (with no external validation like measuring participants’ carbon monoxide levels). What emerges in this analysis is the relevance of the process that leads to the establishment of the quit day (Dday) to stop using tobacco. In addition, technological issues, when tailoring is the focus, are key elements for scrutiny. The high number of dropouts of users of the web platform mandates future research that should concentrate on the matters of the user-centred design of portals. The focus on gains in health through patient-centred care needs more research, so that technology usability be considered within the context of best practices in smoking cessation.
Resumo:
RESUMO - A legionella em meio hospitalar tem sido alvo de preocupação e de várias discussões, sendo esta uma bactéria patogénica que coloniza vários tipos de ambientes aquáticos (naturais e artificiais). Estas bactérias têm a particularidade de se desenvolver em meio aquático mas a infeção apenas é transmitida através de aerossóis de água contaminada, ou seja, por via aérea. Não se transmitindo de pessoa para pessoa. Pelas suas características os sistemas de arrefecimento de ar, nomeadamente as torres de arrefecimento, condensadores evaporativos, humidificadores e sistemas de ar condicionado, são fontes importantes de disseminação da legionella. Assim surge a necessidade da existência de programas de prevenção, que deverão ter em conta uma adequada manutenção, limpeza e desinfeção. Dada a quantidade de frequentadores assim como da especificidade dos mesmos, em meio hospitalar é particularmente importante a eficácia destes sistemas. Ou seja, os sistemas de arrefecimento em hospitais devem, para além de garantir o conforto térmico, ser responsáveis por manter a qualidade do ar e reduzir os riscos existentes a ele associados. O presente estudo pretende conhecer a verdadeira eficácia dos programas de manutenção e vigilância da Legionella, apenas nos sistemas de arrefecimento. Trata-se então de um estudo exploratório, descritivo recolha desta informação in-loco dos sistemas em estudo, de X hospitais da cidade de Lisboa. Na metodologia serão utilizadas grelhas de observação e resultados de colheita de água dos locais de maior risco. A realização deste estudo visa obter um retrato do panorama existente e contribuir para o início de novos estudos epidemiológicos.
Resumo:
21th Annual Conference of the International Group for Lean Construction (IGLC 21), July 2013, Fortaleza, Brazil
Resumo:
RESUMO - O ozono é o principal componente da poluição fotoquímica do ar. Como agente irritante do aparelho respiratório, os seus efeitos sobre a saúde caracterizam-se, essencialmente, por tosse, dispneia, desconforto torácico e alterações da função pulmonar, encontrando-se também associadas à exposição ambiental a O3 tanto uma maior frequência e gravidade de crises de asma como a ocorrência de quadros clínicos de irritação conjuntival. É sobretudo a partir dos anos 50, com a descoberta de concentrações elevadas de ozono em ambientes de trabalho respeitantes à actividade de soldadura «a arco», que aquele gás passa a ser encarado como factor profissional de risco. No início dos anos 60 surgem os primeiros estudos de exposição a O3 em cabinas de avião, suscitados pela ocorrência, em tripulantes e passageiros, de queixas clínicas de irritação do tracto respiratório. Esta sintomatologia era, até então, atribuída à acção de outros factores, designadamente o sistema de ventilação e o baixo teor de humidade do ar. Posteriormente, alguns estudos revelaram que, em voos comerciais subsónicos, os teores elevados de O3 observados no interior das cabinas poderiam ser provocados pela sua insuficiente destruição nos sistemas de entrada de ar.O presente estudo, efectuado em voos de longo curso realizados em aeronaves Airbus A340-300 numa única rota comercial, teve por objectivo avaliar a exposição a ozono no ar interior em cabina de avião. Os teores médios de concentração de ozono observados foram inferiores aos valores susceptíveis de provocarem efeitos adversos sobre o aparelho respiratório. Como valor máximo instantâneo, foi atingida a concentração de 152 ppb. Adicionalmente, foi constatada a influência das estações do ano nos teores de O3. O conjunto dos resultados obtidos permite concluir que as concentrações de ozono no ar interior nas cabinas de avião estudadas são inferiores às correspondentes concentrações máximas admissíveis, tendo, em todos os voos, sido observado o cumprimento da norma da FAA respeitante à protecção da exposição ao ozono em cabinas de aeronaves de aviação comercial.
Resumo:
Dissertação para obtenção do Grau de Doutor em Engenharia do Ambiente
Resumo:
The processes of mobilization of land for infrastructures of public and private domain are developed according to proper legal frameworks and systematically confronted with the impoverished national situation as regards the cadastral identification and regularization, which leads to big inefficiencies, sometimes with very negative impact to the overall effectiveness. This project report describes Ferbritas Cadastre Information System (FBSIC) project and tools, which in conjunction with other applications, allow managing the entire life-cycle of Land Acquisition and Cadastre, including support to field activities with the integration of information collected in the field, the development of multi-criteria analysis information, monitoring all information in the exploration stage, and the automated generation of outputs. The benefits are evident at the level of operational efficiency, including tools that enable process integration and standardization of procedures, facilitate analysis and quality control and maximize performance in the acquisition, maintenance and management of registration information and expropriation (expropriation projects). Therefore, the implemented system achieves levels of robustness, comprehensiveness, openness, scalability and reliability suitable for a structural platform. The resultant solution, FBSIC, is a fit-for-purpose cadastre information system rooted in the field of railway infrastructures. FBSIC integrating nature of allows: to accomplish present needs and scale to meet future services; to collect, maintain, manage and share all information in one common platform, and transform it into knowledge; to relate with other platforms; to increase accuracy and productivity of business processes related with land property management.