6 resultados para Active noise control
Resumo:
White Color tuning is an attractive feature that Organic Light Emitting Diodes (OLEDs) offer. Up until now, there hasn’t been any report that mix both color tuning abilities with device stability. In this work, White OLEDs (W-OLEDs) based on a single RGB blend composed of a blue emitting N,N′-Di(1-naphthyl)-N,N′-diphenyl-(1,1′-biphenyl)-4,4′-diamine (NPB) doped with a green emitting Coumarin-153 and a red emitting 4-(Dicyanomethylene)-2-methyl-6-(4-dimethylaminostyryl)-4H-pyran (DCM1) dyes were produced. The final device structure was ITO/Blend/Bathocuproine (BCP)/ Tris(8-hydroxyquinolinato)aluminium (Alq3)/Al with an emission area of 0.25 cm2. The effects of the changing in DCM1’s concentration (from 0.5% to 1% wt.) allowed a tuning in the final white color resulting in devices capable of emitting a wide range of tunes – from cool to warm – while also keeping a low device complexity and a high stabilitty. Moreover, an explanation on the optoelectrical behavior of the device is presented. The best electroluminescense (EL) points toward 160 cd/m2 of brightness and 1.1 cd/A of efficiency, both prompted to being enhanced. An Impedance Spectroscopy (IS) analysis allowed to study both the effects of BCP as a Hole Blocking Layer and as an aging probe of the device. Finally, as a proof of concept, the emission was increased 9 and 64 times proving this structure can be effectively applied for general lighting.
Resumo:
RESUMO: Relevância e Objectivos: O objectivo deste estudo consistiu em verificar a eficácia e segurança de uma técnica de higiene brônquica – Active Cycle breathing technique (ACBT), na remoção de secreções e desinsuflação em crianças asmáticas. É uma técnica recente, que ainda não foi estudada nesta população. Metodologia: A amostra foi constituída por um total de 14 crianças, com idades compreendidas entre os 6 e 18 anos, com o diagnóstico de asma. Foi dividida em dois grupos: grupo de controlo, constituído por asmáticos estáveis e grupo experimental constituído por asmáticos pós-crise. Ambos receberam o mesmo tratamento, que consistiu numa única sessão de ACBT. Realizaram um exame da função respiratória (variáveis FEV1, PEF, MEF75%, RV e FRC) antes e após a aplicação da técnica. Mediu-se a Saturação de O2 antes, a meio e no fim da aplicação da técnica. Por último, pesaram-se as secreções recolhidas durante a sessão de tratamento. Resultados: Como resultados, quando omparamos o antes e após aplicação do ACBT, obtivemos diferenças significativas no RV (p <0,05) e FRC (p <0,05); muito significativa na Sa02 (p <0,01) e peso de secreções, nos asmáticos pós crise. Ocorreu uma melhoria significativa da saturação (p <0,05) em asmáticos estáveis, não havendo secreções. Não houve efeitos adversos nem broncoespasmo em ambos os grupos.Conclusão: O ACBT é uma técnica que promove a remoção de secreções e diminuição da insuflação na população de asmáticos.--------------------ABSTRACT:Relevance and Goals: the goal of this study was to verify the efficiency and security of a bronchial hygienic technique - Active Cycle Breathing Technique (ACBT) – in the obstruction and insufflation of asthmatic children. This is a new technique that has not yet been studied in this population. Procedures: The subjects were 14 children aged between 6 and 18 years old with asthma diagnosis. They were divided in two groups: the control group with stable asthmatics and the experimental group with post-crisis asthmatics. Both received the same treatment that was a single session of ACBT. They made a lung function test before and after the application of the technique (variables FEV1, PEF, MEF75%, RV and FRC). The level of O2 saturation was measured before, during and after the procedure. In the end, the secretions collected during the treatment were weighted. Results: We observed a significant difference on RV (p ˂0,05), FRC (p ˂0,05), Sa02 (p ˂0,01) and in the weight of the secretions in the post-crisis asthmatics after ACBT. There was a significant improvement of saturation (p ˂0,05) only in the stable asthmatics. There were no adverse effects or bronchospasm in both groups.
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Eletrotécnica e de Computadores
Resumo:
The work presented in this thesis was developed in collaboration with a Portuguese company, BeyonDevices, devoted to pharmaceutical packaging, medical technology and device industry. Specifically, the composition impact and surface modification of two polymeric medical devices from the company were studied: inhalers and vaginal applicators. The polyethylene-based vaginal applicator was modified using supercritical fluid technology to acquire self-cleaning properties and prevent the transport of bacteria and yeasts to vaginal flora. For that, in-situ polymerization of 2-substituted oxazolines was performed within the polyethylene matrix using supercritical carbon dioxide. The cationic ring-opening polymerization process was followed by end-capping with N,N-dimethyldodecylamine. Furthermore, for the same propose, the polyethylene matrix was impregnated with lavender oil in supercritical medium. The obtained materials were characterized physical and morphologically and the antimicrobial activity against bacteria and yeasts was accessed. Materials modified using 2-substituted oxazolines showed an effective killing ability for all the tested microorganisms, while the materials modified with lavender oil did not show antimicrobial activity. Only materials modified with oligo(2-ethyl-2-oxazoline) maintain the activity during the long term stability. Furthermore, the cytotoxicity of the materials was tested, confirming their biocompatibilty. Regarding the inhaler, its surface was modified in order to improve powder flowability and consequently, to reduce powder retention in the inhaler´s nozzle. New dry powder inhalers (DPIs), with different needle’s diameters, were evaluated in terms of internal resistance and uniformity of the emitted dose. It was observed that they present a mean resistance of 0.06 cmH2O0.5/(L/min) and the maximum emitted dose obtained was 68.9% for the inhaler with higher needle´s diameter (2 mm). Thus, this inhaler was used as a test and modified by the coating with a commonly-used force control agent, magnesium stearate, dried with supercritical carbon dioxide (scCO2) and the uniformity of delivered dose tests were repeated. The modified inhaler showed an increase in emitted dose from 68.9% to 71.3% for lactose and from 30.0% to 33.7% for Foradil.
Resumo:
Modern CMOS radio frequency (RF) Receivers have enabled efficient and increasing applications. The main requirement is to have system in a single chip, in order to minimize area and cost. For the purpose it is required the development of inductorless circuits for the key blocks of an RF receiver. Examples of this key blocks are RC oscillators, RF band pass filters, and Low Noise Amplifiers. The present dissertation presents an inductorless wideband MOSFET-only RF Non-Gyrator Type of Active Inductors with low area, low cost, and very low power, capable of covering the whole WMTS, and ISM, band and intended for biomedical applications. The proposed circuit is based on a floating capacitor connected between two controlled current sources. The first current source, which is controlled by the circuit input voltage, has two objectives: supply current to the capacitor (
Resumo:
Modern fully integrated receiver architectures, require inductorless circuits to achieve their potential low area, low cost, and low power. The low noise amplifier (LNA), which is a key block in such receivers, is investigated in this thesis. LNAs can be either narrowband or wideband. Narrowband LNAs use inductors and have very low noise figure, but they occupy a large area and require a technology with RF options to obtain inductors with high Q. Recently, wideband LNAs with noise and distortion cancelling, with passive loads have been proposed, which can have low NF, but have high power consumption. In this thesis the main goal is to obtain a very low area, low power, and low-cost wideband LNA. First, it is investigated a balun LNA with noise and distortion cancelling with active loads to boost the gain and reduce the noise figure (NF). The circuit is based on a conventional balun LNA with noise and distortion cancellation, using the combination of a common-gate (CG) stage and common-source (CS) stage. Simulation and measurements results, with a 130 nm CMOS technology, show that the gain is enhanced by about 3 dB and the NF is reduced by at least 0.5 dB, with a negligible impact on the circuit linearity (IIP3 is about 0 dBm). The total power dissipation is only 4.8 mW, and the active area is less than 50 x 50 m2 . It is also investigated a balun LNA in which the gain is boosted by using a double feedback structure.We propose to replace the load resistors by active loads, which can be used to implement local feedback loops (in the CG and CS stages). This will boost the gain and reduce the noise figure (NF). Simulation results, with the same 130 nm CMOS technology as above, show that the gain is 24 dB and NF is less than 2.7 dB. The total power dissipation is only 5.4 mW (since no extra blocks are required), leading to a figure-of-merit (FoM) of 3.8 mW