7 resultados para hydraulic system behaviour

em RUN (Reposit


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Polyhydroxyalkanoates (PHAs) are biosynthetic polyesters, biodegradable and biocompatible making them of great interest for industrial purposes. The use of low value substrates with mixed microbial communities (MMC) is a strategy currently used to decrease the elevated PHA production costs. PHA production process requires an important step for selection and enrichment of PHA-storing microorganisms which is usually carried out in a Sequencing Batch Reactor (SBR). The aim of this study was to optimize the PHA accumulating culture selection stage using a 2-stage Continuous Stirrer Tank Reactor (CSTR) system. The system was composed by two separate feast and famine bioreactors operated continuously, mimicking the feast and famine phases in a SBR system. Acetate was used as carbon source and biomass seed was highly enriched in Plasticicumulans acidivorans obtained from activated sludge. The system was operated under two different sets of conditions (setup 1 and 2), maintaining a system total retention time of 12 hours and an OLR of 2.25 Cmmol/L.h-1. An average PHB-content of 3.3 % wt was obtained in setup 1 and 4.8% wt in setup 2. Several other experiments were performed in order to better understand the continuous system behaviour, using biomass from the continuous system. With the fed-batch experiment a maximum of 8.1% PHB was stored and the maximum substrate uptake and specific growth rates obtained in the growth experiment (1.15 Cmol Cmol-1.h-1 and 0.53 Cmol Cmol-1.h-1) were close to the ones from continuous system (1.12 Cmol Cmol-1.h-1 and 0.59 Cmol Cmol-1.h-1). The microbial community was characterized trough microscopic visualization, Denaturing Gradient Gel Electrophoresis (DGGE) analysis and Fluorescent in situ hybridization (FISH). The last studied performed mimicked the continuous system by building up a SBR system with all the same operational conditions while adding an extra acetate dosage during the 12 h cycle, simulating the substrate passing from the feast to the famine reactors under continuous operation. It was shown that possibly the continuous system was not able to efficiently select for PHB storing organisms under the operational conditions imposed, although the selected culture was capable of consuming the substrate and grow fast. This main conclusion might have resulted from two major factors affecting the system performance: the ammonium concentration in the Feast reactor and the amount of substrate leaching from the Feast to the Famine reactor.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

In a “perfect” drinking water system, the water quality for the consumers should be the same as the quality of the water leaving the treatment plant. However, some variability along the system can lead to a decrease in water quality (such as discolouration) which is usually reflected in the number of the customer complaints. This change may be related to the amount of sediment in the distribution network, leading to an increase in turbidity at the water supply. Since there is no such thing as a perfect drinking water system, the behaviour of particles in a drinking water network needs a suitable approach in order to understand how it works. Moreover, the combination of measurements, such as turbidity patterns and the Resuspension Potential Method (RPM) aid in the prevention of discoloured water complaints and intervention in the treatment upgrade or the network cleaning. Besides sediments there is also bacterial regrowth in the network, which is related to the water quality and distribution network characteristics. In a theoretical drinking water system higher velocities, temperature and shorter residences times lead to wider bacterial growth. In this study we observe velocity and residence steady-states and bacterial does not seem to be related to either. It can be concluded that adequate measurements of RPM, customer complaints and bacterial concentrations allow a wider knowledge on particle behaviour in drinking water systems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Doutor em Engenharia Electrotécnica e de Computadores

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Doutor em Engenharia Civil

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A Work Project, presented as part of the requirements for the Award of a Masters Degree in Management from the NOVA – School of Business and Economics

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dissertação para a obtenção do Grau de Mestre em Engenharia Biomédica

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the last few years, we have observed an exponential increasing of the information systems, and parking information is one more example of them. The needs of obtaining reliable and updated information of parking slots availability are very important in the goal of traffic reduction. Also parking slot prediction is a new topic that has already started to be applied. San Francisco in America and Santander in Spain are examples of such projects carried out to obtain this kind of information. The aim of this thesis is the study and evaluation of methodologies for parking slot prediction and the integration in a web application, where all kind of users will be able to know the current parking status and also future status according to parking model predictions. The source of the data is ancillary in this work but it needs to be understood anyway to understand the parking behaviour. Actually, there are many modelling techniques used for this purpose such as time series analysis, decision trees, neural networks and clustering. In this work, the author explains the best techniques at this work, analyzes the result and points out the advantages and disadvantages of each one. The model will learn the periodic and seasonal patterns of the parking status behaviour, and with this knowledge it can predict future status values given a date. The data used comes from the Smart Park Ontinyent and it is about parking occupancy status together with timestamps and it is stored in a database. After data acquisition, data analysis and pre-processing was needed for model implementations. The first test done was with the boosting ensemble classifier, employed over a set of decision trees, created with C5.0 algorithm from a set of training samples, to assign a prediction value to each object. In addition to the predictions, this work has got measurements error that indicates the reliability of the outcome predictions being correct. The second test was done using the function fitting seasonal exponential smoothing tbats model. Finally as the last test, it has been tried a model that is actually a combination of the previous two models, just to see the result of this combination. The results were quite good for all of them, having error averages of 6.2, 6.6 and 5.4 in vacancies predictions for the three models respectively. This means from a parking of 47 places a 10% average error in parking slot predictions. This result could be even better with longer data available. In order to make this kind of information visible and reachable from everyone having a device with internet connection, a web application was made for this purpose. Beside the data displaying, this application also offers different functions to improve the task of searching for parking. The new functions, apart from parking prediction, were: - Park distances from user location. It provides all the distances to user current location to the different parks in the city. - Geocoding. The service for matching a literal description or an address to a concrete location. - Geolocation. The service for positioning the user. - Parking list panel. This is not a service neither a function, is just a better visualization and better handling of the information.