2 resultados para Oceanographic instruments

em RUN (Repositório da Universidade Nova de Lisboa) - FCT (Faculdade de Cienecias e Technologia), Universidade Nova de Lisboa (UNL), Portugal


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The state of research on the evolution of marine bivalve taxonomic diversity of the Mediterranean Pliocene is analysed. The following assertions are discussed: 1) The Early Pliocene malacofauna is characterized by a high number of warm-water taxa and a high taxonomic diversity with respect to that of the present time. 2) The first appreciable extinction event in the Mediterranean Pliocene approximates or just follows the FO of Globorotalia bononiensis. 3) The second appreciable extinction event is between the LAD of Discoaster tamalis and the LAD of Discoaster surculus . 4) A third minor extinction event is penecontemporaneous with the FO of Globorotalia inflaia. Taking into account the available data on the Pliocene extinction events it has been possible to distinguish 4 different molluscan units with different climatic-oceanographic significance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This present study aimed to investigate the fatigue life of unused (new) endodontic instruments made of NiTi with control memory by Coltene™ and subjected to the multi curvature of a mandibular first molar root canal. Additionally, the instrument‟s structural behaviour was analysed through non-linear finite element analysis (FEA). The fatigue life of twelve Hyflex™ CM files was assessed while were forced to adopt a stance with multiple radius of curvature, similar to the ones usually found in a mandibular first molar root canal; nine of them were subjected to Pecking motion, a relative movement of axial type. To achieve this, it was designed an experimental setup with the aim of timing the instruments until fracture while worked inside a stainless steel mandibular first molar model with relative axial motion to simulate the pecking motion. Additionally, the model‟s root canal multi-curvature was confirmed by radiography. The non-linear finite element analysis was conducted using the computer aided design software package SolidWorks™ Simulation, in order to define the imposed displacement required by the FEA, it was necessary to model an endodontic instrument with simplified geometry using SolidWorks™ and subsequently analyse the geometry of the root canal CAD model. The experimental results shown that the instruments subjected to pecking motion displayed higher fatigue life values and higher lengths of fractured tips than those with only rotational relative movement. The finite element non-linear analyses shown, for identical conditions, maximum values for the first principal stress lower than the yield strength of the material and those were located in similar positions to the instrument‟s fracture location determined by the experimental testing results.