69 resultados para 3D object detection


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Breast cancer is the most common type of cancer worldwide. The effectiveness of its treatment depends on early stage detection, as well as on the accuracy of its diagnosis. Recently, diagnosis techniques have been submitted to relevant breakthroughs with the upcoming of Magnetic Resonance Imaging, Ultrasound Sonograms and Positron Emission Tomography (PET) scans, among others. The work presented here is focused on studying the application of a PET system to a Positron Emission Mammography (PEM) system. A PET/PEM system works under the principle that a scintillating crystal will detect a gamma-ray pulse, originated at the cancerous cells, converting it into a correspondent visible light pulse. The latter must then be converted into an electrical current pulse by means of a Photo- -Sensitive Device (PSD). After the PSD there must be a Transimpedance Amplifier (TIA) in order to convert the current pulse into a suitable output voltage, in a time period lower than 40 ns. In this Thesis, the PSD considered is a Silicon Photo-Multiplier (SiPM). The usage of this recently developed type of PSD is impracticable with the conventional TIA topologies, as it will be proven. Therefore, the usage of the Regulated Common-Gate (RCG) topology will be studied in the design of the amplifier. There will be also presented two RCG variations, comprising a noise response improvement and differential operation of the circuit. The mentioned topology will also be tested in a Radio-Frequency front-end, showing the versatility of the RCG. A study comprising a low-voltage self-biasing feedback TIA will also be shown. The proposed circuits will be simulated with standard CMOS technology (UMC 130 nm), using a 1.2 V power supply. A power consumption of 0.34 mW with a signal-to-noise ratio of 43 dB was achieved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Part of this thesis will be published in the following: Gomes, B.C., Santos, B. 2015. Methods for studying microRNAs expression and their targets in formalin-fixed, paraffin-embedded (FFPE) breast cancer tissues. In Methods in Molecular Biology: Cancer Drug Resistance (Rueff, J. & Rodrigues, A.S. eds), Springer Protocols.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simulação dinâmica de reservatórios de petróleo requer a alocação de permeabilidades equivalentes para todos os blocos. A determinação da permeabilidade equivalente em reservatórios fraturados é uma questão complexa e crítica no fluxograma de modelação, porque é totalmente dependente da geometria 3D sistema de fraturas, e respetivas aberturas, que muitas vezes são mal conhecidos. Para avaliar a permeabilidade equivalente de blocos fraturados, o método do tensor ou de Oda é um dos mais utilizados. É expedito e eficiente mesmo para a sistemas com vários milhões de fraturas. Todavia, na literatura são apontadas algumas críticas, por exemplo, sobrestima a permeabilidade em blocos pouco fraturados e subestima-a em blocos muito fraturados. Este trabalho tem como objetivos, revisitar a problemática da caracterização da permeabilidade equivalente em blocos de reservatórios fraturados. Recorreu-se a um pacote de programas informáticos FROM3D-K (fractures object model – permeability evaluation) desenvolvidos e/ ou adaptados no contexto deste trabalho e que permitem as funcionalidades: (1) simulação estocástica 3D de fraturas; (2) determinação da permeabilidade equivalente pelo método do tensor; (3) determinação da permeabilidade equivalente pelo método de upscaling de microblocos. Estas funções permitem que a mesma rede de fraturas seja avaliada pelos dois métodos. Para a demonstração de resultados mostram-se dois exemplos, o primeiro onde são simuladas fraturas condicionadas a estatísticas sintéticas de orientação, intensidade e abertura e o segundo onde se utilizam dados FMI de poço de um reservatório fraturado.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The main objective of this thesis was the development of a gold nanoparticle-based methodology for detection of DNA adducts as biomarkers, to try and overcome existing drawbacks in currently employed techniques. For this objective to be achieved, the experimental work was divided in three components: sample preparation, method of detection and development of a model for exposure to acrylamide. Different techniques were employed and combined for de-complexation and purification of DNA samples (including ultrasonic energy, nuclease digestion and chromatography), resulting in a complete protocol for sample treatment, prior to detection. The detection of alkylated nucleotides using gold nanoparticles was performed by two distinct methodologies: mass spectrometry and colorimetric detection. In mass spectrometry, gold nanoparticles were employed for laser desorption/ionisation instead of the organic matrix. Identification of nucleotides was possible by fingerprint, however no specific mass signals were denoted when using gold nanoparticles to analyse biological samples. An alternate method using the colorimetric properties of gold nanoparticles was employed for detection. This method inspired in the non-cross-linking assay allowed the identification of glycidamide-guanine adducts and DNA adducts generated in vitro. For the development of a model of exposure, two different aquatic organisms were studies: a goldfish and a mussel. Organisms were exposed to waterborne acrylamide, after which mortality was recorded and effect concentrations were estimated. In goldfish, both genotoxicity and metabolic alterations were assessed and revealed dose-effect relationships of acrylamide. Histopathological alterations were verified primarily in pancreatic cells, but also in hepatocytes. Mussels showed higher effect concentrations than goldfish. Biomarkers of oxidative stress, biotransformation and neurotoxicity were analysed after prolonged exposure, showing mild oxidative stress in mussel cells, and induction of enzymes involved in detoxification of oxygen radicals. A qualitative histopathological screening revealed gonadotoxicity in female mussels, which may present some risk to population equilibrium.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study analyses financial data using the result characterization of a self-organized neural network model. The goal was prototyping a tool that may help an economist or a market analyst to analyse stock market series. To reach this goal, the tool shows economic dependencies and statistics measures over stock market series. The neural network SOM (self-organizing maps) model was used to ex-tract behavioural patterns of the data analysed. Based on this model, it was de-veloped an application to analyse financial data. This application uses a portfo-lio of correlated markets or inverse-correlated markets as input. After the anal-ysis with SOM, the result is represented by micro clusters that are organized by its behaviour tendency. During the study appeared the need of a better analysis for SOM algo-rithm results. This problem was solved with a cluster solution technique, which groups the micro clusters from SOM U-Matrix analyses. The study showed that the correlation and inverse-correlation markets projects multiple clusters of data. These clusters represent multiple trend states that may be useful for technical professionals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A transimpedance amplifier (TIA) is used, in radiation detectors like the positron emission tomography(PET), to transform the current pulse produced by a photo-sensitive device into an output voltage pulse with a desired amplitude and shape. The TIA must have the lowest noise possible to maximize the output. To achieve a low noise, a circuit topology is proposed where an auxiliary path is added to the feedback TIA input, In this auxiliary path a differential transconductance block is used to transform the node voltage in to a current, this current is then converted to a voltage pulse by a second feedback TIA complementary to the first one, with the same amplitude but 180º out of phase with the first feedback TIA. With this circuit the input signal of the TIA appears differential at the output, this is used to try an reduced the circuit noise. The circuit is tested with two different devices, the Avalanche photodiodes (APD) and the Silicon photomultiplier (SIPMs). From the simulations we find that when using s SIPM with Rx=20kΩ and Cx=50fF the signal to noise ratio is increased from 59 when using only one feedback TIA to 68.3 when we use an auxiliary path in conjunction with the feedback TIA. This values where achieved with a total power consumption of 4.82mv. While the signal to noise ratio in the case of the SIPM is increased with some penalty in power consumption.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nas últimas décadas o aumento da expansão das áreas urbanas conduziu a rápidas mudanças nos ambientes urbanos. Estas mudanças necessitam de uma observação e compreensão, por forma a permitir a monitorização e avaliação do processo de planeamento urbano. A utilização de dados obtidos por Deteção Remota (DR), aliada aos Sistemas de Informação Geográfica (SIG), surge como uma fonte de informação válida para modelar, recolher, armazenar, exibir e analisar os sistemas urbanos. Neste contexto, a informação planimétrica e altimétrica recolhida por sensores remotos pode ser explorada por forma a extrair informação acerca do uso e ocupação do solo, e apresenta-la sob a forma de indicadores para apoio à decisão. Um sistema de indicadores urbanos baseados em dados obtidos por DR constitui uma ferramenta para as cidades transmitirem os diferentes riscos urbanos bem como na promoção de medidas e estratégias para um eficiente planeamento urbano. A dissertação de mestrado proposta tem como principal objetivo a criação de um sistema de indicadores urbanos que caracterize a cidade de Lisboa ao nível das áreas verdes e do volume construído. Assim, de forma a atingir o objetivo principal é desenvolvida uma metodologia baseada em informação altimétrica e planimétrica que permite analisar as áreas verdes da cidade de Lisboa bem como o volume construído. A informação altimétrica urbana (3D) é derivada de dados cartográficos oficiais (curvas de nível que originam um Modelo Digital de Terreno) e informação recolhida por LiDAR (Light Detection And Ranging) (que representa o Modelo Digital de Superfície). A informação 2D é extraída de uma imagem do satélite de alta resolução Worldview-2 de 2010, com um pixel de 0,5m, do concelho de Lisboa, através de técnicas de processamento digital de imagem. A informação recolhida permite, por um lado a modelação 3D do edificado, e por outro a quantificação 2D da cobertura vegetal em meio urbano. Posteriormente, num ambiente SIG, a informação extraída é cruzada com dados censitários e dados de uso e ocupação do solo. A análise ocorre tendo por base as Subsecções Estatísticas (SSE) da cidade de Lisboa (INE, 2011) e o sistema proposto inclui assim a extração de indicadores divididos tematicamente em indicadores de área e indicadores de volume. Os resultados obtidos permitem relacionar as áreas verdes, a população e o volume construído.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis is one of the first reports of digital microfluidics on paper and the first in which the chip’s circuit was screen printed unto the paper. The use of the screen printing technique, being a low cost and fast method for electrodes deposition, makes the all chip processing much more aligned with the low cost choice of paper as a substrate. Functioning chips were developed that were capable of working at as low as 50 V, performing all the digital microfluidics operations: movement, dispensing, merging and splitting of the droplets. Silver ink electrodes were screen printed unto paper substrates, covered by Parylene-C (through vapor deposition) as dielectric and Teflon AF 1600 (through spin coating) as hydrophobic layer. The morphology of different paper substrates, silver inks (with different annealing conditions) and Parylene deposition conditions were studied by optical microscopy, AFM, SEM and 3D profilometry. Resolution tests for the printing process and electrical characterization of the silver electrodes were also made. As a showcase of the applications potential of these chips as a biosensing device, a colorimetric peroxidase detection test was successfully done on chip, using 200 nL to 350 nL droplets dispensed from 1 μL drops.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As the complexity of markets and the dynamicity of systems evolve, the need for interoperable systems capable of strengthening enterprise communication effectiveness increases. This is particularly significant when it comes to collaborative enterprise networks, like manufacturing supply chains, where several companies work, communicate, and depend on each other, in order to achieve a specific goal. Once interoperability is achieved, that is once all network parties are able to communicate with and understand each other, organisations are able to exchange information along a stable environment that follows agreed laws. However, as markets adapt to new requirements and demands, an evolutionary behaviour is triggered giving space to interoperability problems, thus disrupting the sustainability of interoperability and raising the need to develop monitoring activities capable of detecting and preventing unexpected behaviour. This work seeks to contribute to the development of monitoring techniques for interoperable SOA-based enterprise networks. It focuses on the automatic detection of harmonisation breaking events during real-time communications, and strives to develop and propose a methodological approach to handle these disruptions with minimal or no human intervention, hence providing existing service-based networks with the ability to detect and promptly react to interoperability issues.