59 resultados para multi-quasi-elliptic operators
Resumo:
Double degree. A Work Project presented as part of the requirements for the Award of a Masters Degree in Management from the NOVA- School of Business and Economics and Warsaw School of Economics
Resumo:
Environmental pollution is one of the major and most important problems of the modern world. In order to fulfill the needs and demands of the overgrowing human population, developments in agriculture, medicine, energy sources, and all chemical industries are necessary (Ali 2010). Over the last century, the increased industrialization and continued population growth led to an augmented production of environmental pollutants that are released into air, water, and soil, with significant impact in the degradation of various ecosystems (Ali 2010, Khan et al. 2013).(...)
Resumo:
The following work project illustrates the strategic issues There App, a mobile application, faces regarding the opportunity to expand from its current state as a product to a multisided platform. Initially, a market analysis is performed to identify the ideal customer groups to be integrated in the platform. Strategic design issues are then discussed on how to best match its value proposition with the identified market opportunity. Suggestions on how the company should organize its resources and operational processes to best deliver on its value proposition complete the work.
Resumo:
An energy harvesting system requires an energy storing device to store the energy retrieved from the surrounding environment. This can either be a rechargeable battery or a supercapcitor. Due to the limited lifetime of rechargeable batteries, they need to be periodically replaced. Therefore, a supercapacitor, which has ideally a limitless number of charge/discharge cycles can be used to store the energy; however, a voltage regulator is required to obtain a constant output voltage as the supercapacitor discharges. This can be implemented by a Switched-Capacitor DC-DC converter which allows a complete integration in CMOS technology, although it requires several topologies in order to obtain a high efficiency. This thesis presents the complete analysis of four different topologies in order to determine expressions that allow to design and determine the optimum input voltage ranges for each topology. To better understand the parasitic effects, the implementation of the capacitors and the non-ideal effect of the switches, in 130 nm technology, were carefully studied. With these two analysis a multi-ratio SC DC-DC converter was designed with an output power of 2 mW, maximum efficiency of 77%, and a maximum output ripple, in the steady state, of 23 mV; for an input voltage swing of 2.3 V to 0.85 V. This proposed converter has four operation states that perform the conversion ratios of 1/2, 2/3, 1/1 and 3/2 and its clock frequency is automatically adjusted to produce a stable output voltage of 1 V. These features are implemented through two distinct controller circuits that use asynchronous time machines (ASM) to dynamically adjust the clock frequency and to select the active state of the converter. All the theoretical expressions as well as the behaviour of the whole system was verified using electrical simulations.
Resumo:
As nonprofits do not have access to the same capital markets as for-profit enterprises, organizations usually scramble for funding to keep up with their mission. This scenario can be changed through the use of the right financial engineering. This Work Project aims at studying an innovative financing mechanism based on the concept of quasi-equity for organizations devoted to social ends to cope with their capital needs. A quasi-equity investment model is built for the Portuguese social business SPEAK, and an in-depth assessment of its current financial, organizational and impact situations is conducted. This is a pioneer case study in Portugal.
Resumo:
RESUMO - Estudos anteriores nos Cuidados de Saúde Primários (CSP) apontam para um incremento da Deteção Precoce (DP) e Intervenções Breves (IB) em pacientes com Problemas Ligados ao Álcool (PLA) após formação apropriada dos profissionais de saúde (com melhoria das suas atitudes). Este estudo quasi experimental, exploratório, é pioneiro no âmbito da Saúde Ocupacional (SO) para a implementação de Rastreio/DP e IB nos PLA. O objetivo principal foi avaliar se uma formação sobre Rastreio/DP e IB pode melhorar as atitudes dos profissionais de SO ao lidar com os PLA em Meio Laboral (PLAML). Foi aplicado um questionário em duas partes: Q1/pré-formação (variáveis sociodemográficas, profissionais, competências em alcoologia, experiência pessoal com álcool/familiares com PLA, dificuldades em lidar com trabalhadores com PLA, AUDIT-C e SAAPPQ) e Q2/pós-formação (avaliação da formação e das atitudes SAAPPQ - Adequação, Legitimidade, Motivação, Autoestima e Satisfação). Os resultados na amostra (N=39) revelaram um aumento sobretudo na Adequação e Satisfação. No entanto, naqueles com níveis baixos das atitudes pré-formação constou-se melhoria das atitudes à excepção da Autoestima e foram encontradas algumas associações com as características do perfil inicial dos participantes. Sugerem-se estudos posteriores para identificação de pacotes formativos mais efetivos e propostas para um Plano integrador de RIB para PLAML
Resumo:
O processo de reestruturação do setor elétrico deu origem à criação de diferentes estruturas de mercado, tendo como objetivo o aumento da competitividade e eficiência. Atualmente, a comercialização de energia elétrica pode ser realizada com recurso a mercados em bolsa ou através da celebração de contratos bilaterais. Sendo o mercado em bolsa caraterizado por uma forte volatilidade de preços, e considerando a atribuição de incentivos para o crescimento da geração renovável não controlada, revela-se importante analisar o impacto de níveis elevados de energia eólica sobre os preços do mercado diário. Neste contexto, a presente dissertação tem como principais objetivos estudar e implementar os algoritmos de preço marginal único e preço marginal local, normalmente utilizados no mercado em bolsa, bem como dotar o simuladormultiagente MANREM com um módulo para simular os mercados diário e intradiário, e analisar o impacto de níveis elevados de energia eólica sobre os preços do mercado diário. O estudo detalhado de um caso prático e os resultados obtidos com recurso ao simuladormulti-agente permitiram replicar, em computador, o impacto esperado, sendo possível observar uma redução de preços e uma alteração dos compromissos de produção dos produtores convencionais. O estudo contemplou a simulação do mercado diário com recurso aos algoritmos de preço marginal único e preço marginal local, podendo constatar-se que a ferramenta multi-agente constitui um auxiliar importante à tomada de decisão nos mercados de eletricidade.
Resumo:
An ion emitter consisting of a sharp silver tip covered in RbAg4I5 solid electrolyte film has been developed and studied. An accelerating potential is applied and Ag+ ions are emitted from the tip’s apex by field evaporation. The emitted ions are collected by a Faraday cup, producing a current on the pico/nanoampere level which is read by an electrometer. The tips were produced mechanically by sandpaper polishing. The sharpest tip produced had a 2:4 m apex radius. Two deposition methods were studied: thermal vacuum and pulsed laser deposition. The best tip produced a peak current value of 96nA at 180oC, and a quasi-stable 4nA emission current at 160oC, both using an extraction potential of 10kV . The emission dependence on time, temperature and accelerating potential has been studied. Deposited films were characterized by X-ray diffraction (XRD), profilometry, optical and Scanning Electron Microscope (SEM) and Secondary Ion Mass Spectroscopy (SIMS) measurements. Several ion emitters were developed, the latter ones were all able to maintain stable high ion emissions for long periods of time. This investigation was a continuation of an ongoing project backed by the European Space Agency, with the objective of making a proof of concept of this kind of ion emitter with potential application on ion thrusters for orbiting satellites. Going forward, it would be interesting to make a finer analysis of the electrolyte’s conductivity at high temperatures, explore Wien Effect-based emission and to further develop a multi-tip ion emitter prototype.
Resumo:
ABSTRACT - Objectives: We attempted to show how the implementation of the key elements of the World Health Organization Patient Safety Curriculum Guide Multi-professional Edition in an undergraduate curriculum affected the knowledge, skills, and attitudes towards patient safety in a graduate entry Portuguese Medical School. Methods: After receiving formal recognition by the WHO as a Complementary Test Site and approval of the organizational ethics committee , the validated pre-course questionnaires measuring the knowledge, skills, and attitudes to patient safety were administered to the 2nd and3rd year students pursuing a four-year course (N = 46). The key modules of the curriculum were implemented over the academic year by employing a variety of learning strategies including expert lecturers, small group problem-based teaching sessions, and Simulation Laboratory sessions. The identical questionnaires were then administered and the impact was measured. The Curriculum Guide was evaluated as a health education tool in this context. Results: A significant number of the respondents, 47 % (n = 22), reported having received some form of prior patient safety training. The effect on Patient Safety Knowledge was assessed by using the percentage of correct pre- and post-course answers to construct 2 × 2 contingency tables and by applying Fishers’ test (two-tailed). No significant differences were detected (p < 0.05). To assess the effect of the intervention on Patient Safety skills and attitudes, the mean and standard deviation were calculated for the pre and post-course responses, and independent samples were subjected to Mann-Whitney’s test. The attitudinal survey indicated a very high baseline incidence of desirable attitudes and skills toward patient safety. Significant changes were detected (p < 0.05) regarding what should happen if an error is made (p = 0.016), the role of healthcare organizations in error reporting (p = 0.006), and the extent of medical error (p = 0.005). Conclusions: The implementation of selected modules of the WHO Patient Safety Curriculum was associated with a number of positive changes regarding patient safety skills and attitudes, with a baseline incidence of highly desirable patient safety attitudes, but no measureable change on the patient safety knowledge, at the University of Algarve Medical School. The significance of these results is discussed along with implications and suggestions for future research.
Resumo:
Os sistemas de comunicação sem fios são sistemas de difusão por natureza. Devido a essa sua natureza, um dos problemas inerentes à mesma deve-se à segurança e ao secretismo, pois se o canal é partilhado a informação facilmente é obtida por um utilizador não autorizado, ao contrário dos sistemas de comunicação com fios. Tradicionalmente, a introdução de segurança em sistemas de comunicação, resulta na encriptação da informação, resultante de protocolos de encriptação. No entanto, a segurança através da criptografia baseia-se na premissa de que o utilizador não autorizado tem uma capacidade de processamento limitada, pois senão poderia simplesmente tentar todas as combinações possíveis e obter a chave de encriptação. Como a capacidade de processamento tem crescido exponencialmente, este tipo de sistemas tem se tornado cada vez mais complexos para não se tornarem obsoletos. A introdução de segurança na camada física torna-se então uma opção apelativa pois pode servir como um complemento, visto que os sistemas de criptografia funcionam em camadas superiores independentes da camada fisica, apresentando assim uma abordagem multi-camada em termos de segurança. Tipicamente as técnicas de segurança no nível físico podem se agrupar em 2 tipos: técnicas que se baseiam em códigos, ou técnicas que exploram variações temporais e espaciais do canal. As primeiras diminuem a eficiência espectral do sistema, e as segundas apresentam bons resultados em ambientes dinâmicos, mas em ambientes estáticos não são muito promissores. Há também a necessidade de aumentar as taxas de transmissão nos próximos sistemas de comunicação. Devido a estes requisitos, uma das tecnologias propostas para a nova geração de comunicações, é uma tecnologia baseada numa arquitectura Multiple-Input-Multiple-Output(MIMO). Esta tecnologia é promissora e consegue atingir taxas de transferências que correspondem aos requisitos propostos. Apresenta-se assim uma nova técnica de segurança no nível físico, que explora as caracteristicas físicas do sistema, como um complemento a outras medidas de segurança em camadas mais altas. Esta técnica não provoca diminuição da eficiência espectral e é independente do canal, o que tenta solucionar os problemas das restantes técnicas já existentes.
Resumo:
Field lab: Business project
Resumo:
This present study aimed to investigate the fatigue life of unused (new) endodontic instruments made of NiTi with control memory by Coltene™ and subjected to the multi curvature of a mandibular first molar root canal. Additionally, the instrument‟s structural behaviour was analysed through non-linear finite element analysis (FEA). The fatigue life of twelve Hyflex™ CM files was assessed while were forced to adopt a stance with multiple radius of curvature, similar to the ones usually found in a mandibular first molar root canal; nine of them were subjected to Pecking motion, a relative movement of axial type. To achieve this, it was designed an experimental setup with the aim of timing the instruments until fracture while worked inside a stainless steel mandibular first molar model with relative axial motion to simulate the pecking motion. Additionally, the model‟s root canal multi-curvature was confirmed by radiography. The non-linear finite element analysis was conducted using the computer aided design software package SolidWorks™ Simulation, in order to define the imposed displacement required by the FEA, it was necessary to model an endodontic instrument with simplified geometry using SolidWorks™ and subsequently analyse the geometry of the root canal CAD model. The experimental results shown that the instruments subjected to pecking motion displayed higher fatigue life values and higher lengths of fractured tips than those with only rotational relative movement. The finite element non-linear analyses shown, for identical conditions, maximum values for the first principal stress lower than the yield strength of the material and those were located in similar positions to the instrument‟s fracture location determined by the experimental testing results.