47 resultados para Yersinia pestis F1 antigen detection
Resumo:
This dissertation presents an approach aimed at three-dimensional perception’s obstacle detection on all-terrain robots. Given the huge amount of acquired information, the adversities such environments present to an autonomous system and the swiftness, thus required, from each of its navigation decisions, it becomes imperative that the 3-D perceptional system to be able to map obstacles and passageways in the most swift and detailed manner. In this document, a hybrid approach is presented bringing the best of several methods together, combining the lightness of lesser meticulous analyses with the detail brought by more thorough ones. Realizing the former, a terrain’s slope mapping system upon a low resolute volumetric representation of the surrounding occupancy. For the latter’s detailed evaluation, two novel metrics were conceived to discriminate the little depth discrepancies found in between range scanner’s beam distance measurements. The hybrid solution resulting from the conjunction of these two representations provides a reliable answer to traversability mapping and a robust discrimination of penetrable vegetation from that constituting real obstructions. Two distinct robotic platforms offered the possibility to test the hybrid approach on very different applications: a boat, under an European project, the ECHORD Riverwatch, and a terrestrial four-wheeled robot for a national project, the Introsys Robot.
Resumo:
RESUMO:RESUMO: Nos últimos anos a ultrassonografia emergiu como um instrumento importante no diagnóstico da patologia torácica. O progresso tecnológico possibilitou a conceção de novos equipamentos como a ecoendoscopia brônquica radial e linear. Verificou-se, igualmente, o aparecimento de indicações para a realização de ecografia transtorácica. Uma das principais doenças impulsionadoras da técnica ultrassonográfica no tórax foi o cancro do pulmão, primeira causa de morte oncológica a nível mundial. A aplicabilidade e conhecimento do papel dos ultrassons no âmbito do diagnóstico e estadiamento do cancro do pulmão não se encontram esgotados, persistindo focos de controvérsia e dúvida científica que se pretendem esclarecer. A presente tese foi organizada em cinco capítulos: o primeiro abordou de forma geral e introdutória o estado da arte referente à ultrassonografia torácica, cancro do pulmão e a sua conjugação; o segundo destacou os principais objetivos; o terceiro sumarizou a metodologia utilizada; o quarto englobou os cinco estudos publicados, descritos subsequentemente, e o quinto incluiu uma discussão concisa, as principais conclusões e perspetivas futuras. O primeiro estudo avaliou a rentabilidade diagnóstica, segurança e curva de aprendizagem num coorte de 179 doentes submetidos a ecoendoscopia brônquica linear. De acordo com as indicações para este procedimento os doentes foram subdivididos em três grupos: (1) diagnóstico, (2) diagnóstico e estadiamento e (3) estadiamento. Para o primeiro, segundo e terceiro grupos a sensibilidade da ecoendoscopia foi 86.1%, 86.7% e 95% respetivamente e a precisão técnica foi 87.5%, 93.1% e 97.7% respetivamente. O treino originou um aumento progressivo do número de locais puncionados por doente, com menor duração e sem complicações, comprovando a eficácia e segurança do método quando realizado na população Portuguesa por broncologistas com experiência. O segundo estudo foi conduzido para averiguar a eficácia e custo da ecoendoscopia brônquica linear realizada através da via aérea e/ou esófago no diagnóstico de lesões sugestivas de neoplasia do pulmão, após ineficácia das técnicas convencionais. Nos doentes incluídos prospetivamente alcançou-se um diagnóstico definitivo em 106 casos (87.6%). A sensibilidade global para o diagnóstico de cancro do pulmão foi 89.8%, a especificidade foi 100%, o valor preditivo positivo foi 100%, o valor preditivo negativo foi 20% e a precisão foi 90.1%. Esta estratégia ultrassonográfica abrangente evitou intervenções cirúrgicas diagnósticas em doentes anteriormente submetidos a broncoscopia flexível ou punção aspirativa transtorácica guiada por tomografia computorizada, proporcionando uma redução significativa dos custos. No terceiro estudo investigou-se a viabilidade e papel da conjugação da ecoendoscopia brônquica linear com técnicas moleculares na avaliação de antigénios tumorais e padrões de metastização ganglionar em doentes com cancro do pulmão de não-pequenas células (CPNPC). Os marcadores citoqueratina 19 (CK-19), antigénio carcinoembrionário (CEA), molécula de adesão celular epitelial (EPCAM), sialyl-Lewis X e CD44 foram determinados nos aspirados ganglionares de 33 doentes com neoplasia e 17 controlos 10 Ultrassonografia através de citometria de fluxo (CF) e reação em cadeia da polimerase em tempo real (RTPCR). Os doentes com CPNPC possuíam um compartimento celular epitelial significativamente aumentado e com marcação superior de CK-19 comparativamente ao grupo de controlo. O compartimento imune foi também analisado nestas amostras e revelou-se alterado no CPNPC com aumento da população de monócitos e diminuição das subpopulações linfocitárias. Os transcriptos de CK-19, CEA e EPCAM estavam elevados nos doentes com cancro do pulmão, identificando-se uma correlação positiva entre estes marcadores e o tamanho da lesão primária. Concluiu-se que a identificação de CK-19, CEA e EPCAM nas amostras obtidas por ecoendoscopia e avaliadas por CF e RTPCR foi viável, podendo auxiliar na deteção de metástases ganglionares no CPNPC. O quarto estudo envolveu a combinação da ecoendoscopia brônquica radial com uma criosonda para o diagnóstico de lesões pulmonares sólidas periféricas. Foi determinada a viabilidade, rentabilidade diagnóstica, tamanho das amostras e segurança do método. Lesões inferiores a 40mm foram localizadas por ultrassonografia sendo os doentes randomizados para a realização de biópsias transbrônquicas com pinça seguidas por criosonda ou vice-versa. Nos 39 casos incluídos a lesão foi visualizada pela minisonda em 31 doentes (79.5%), com 80.6% de prevalência de cancro do pulmão na amostra. A rentabilidade diagnóstica da pinça de biópsia foi 61.3% e da criosonda foi 74.2%. O tamanho do tecido adquirido pelas criobiópsias foi significativamente maior do que o alcançado por pinça (11.17mm2 vs. 4.69mm2, p<0.001). Ocorreu um único caso de hemorragia moderada, controlada através de medidas conservadoras. As biópsias transbrônquicas com criosonda sob orientação de ecoendoscopia radial foram seguras e eficazes na obtenção de amostras histológicas. O quinto estudo determinou o valor diagnóstico da ecografia transtorácica na identificação de malignidade em doentes com derrame pleural de natureza indeterminada. Foram examinados de forma prospetiva 154 doentes. Os resultados clínicos e radiológicos de cada caso foram ocultados ao executante do exame que gerou imagens estáticas e vídeos ultrassonográficos relevantes. Estes foram posteriormente visualizados, sendo as suas características classificadas por revisores independentes e comparadas com o diagnóstico definitivo. Em 66 casos o diagnóstico foi de derrame pleural maligno (68.2% com cancro do pulmão) e em 67 de derrame benigno. A ecografia torácica obteve 80.3% de sensibilidade, 83.6% de especificidade, 81.2% de valor preditivo negativo e 82.8% de valor preditivo positivo na deteção de malignidade. A nodularidade pleural ou diafragmática, espessamento pleural superior a 10mm e sinal de swirling foram significativamente diferentes (p<0.001) sendo sugestivos de derrame maligno. A existência de nodularidade pleural e ausência de broncograma aéreo ecográfico aumentaram a probabilidade de malignidade (OR 29.0 e OR 10.4, respetivamente). A ecografia transtorácica permitiu diferenciar derrame pleural maligno do benigno. A existência de nódulos pleurais constituiu o fator discriminador mais relevante. Em conclusão, os resultados desta tese possibilitam uma melhor compreensão do papel da ecoendoscopia brônquica (linear e radial) e ecografia transtorácica no diagnóstico e estadiamento do cancro do pulmão, com implicações e aplicabilidade na prática clínica.------------- ABSTRACT: In recent years ultrasonography has emerged as an important instrument in the diagnosis of thoracic diseases. Technological progress has enabled the design of new equipment such as radial and linear endobronchial ultrasound. In addition, indications for transthoracic echography were established. One of the main diseases responsible for the progression of chest sonography was lung cancer, the leading cause of cancer mortality worldwide. The applicability and knowledge of the role of ultrasonography in diagnosing and staging lung cancer is not depleted, persisting foci of controversy and scientific doubt that we intend to elucidate. The present thesis was organized into five chapters: the first included a general introduction regarding chest ultrasound, lung cancer and their combination; the second emphasized the main objectives; the third summarized the methodology used; the fourth encompassed the five published studies, subsequently described, and the fifth included a concise discussion, the main findings and future perspectives. The first study evaluated the diagnostic yield, safety and learning curve in a cohort of 179 patients submitted to linear endobronchial ultrasound. According to procedure indications, the patients were divided into three groups: (1) diagnosis, (2) diagnosis and staging, and (3) staging. For the first, second and third groups, endobronchial ultrasound sensitivity was 86.1%, 86.7% and 95% respectively and accuracy was 87.5%, 93.1% and 97.7% respectively. Practise led to an increase number of punctured sites per patient, in a shorter period of time and without complications, proving the safety and efficacy of the method when performed in the Portuguese population by expert echoscopists. The second study was conducted to determine the efficacy and cost of linear endobronchial ultrasound performed through the airway and/or oesophagus for diagnosis of lesions suggestive of lung cancer, after failure of conventional techniques. Of the patients prospectively enrolled a definitive diagnosis was reached in 106 cases (87.6%). The overall sensitivity for the diagnosis of lung cancer was 89.8%, specificity was 100%, positive predictive value was 100%, negative predictive value was 20% and accuracy was 90.1%. In conclusion, this global ultrasonographic strategy avoided diagnostic surgical procedures in patients that had undergone flexible bronchoscopy or computed tomography-guided transthoracic needle aspiration, providing a significant cost reduction. In the third study, the feasibility and role of linear endobronchial ultrasound combined with molecular techniques in the evaluation of tumour antigens and patterns of lymph node metastasis in patients with non-small cell lung cancer (NSCLC) was investigated. Cytokeratin 19 (CK-19), carcinoembryonic antigen (CEA), epithelial cell adhesion molecule (EPCAM), sialyl Lewis-X and CD44 were determined in lymph node aspirates of 33 lung cancer patients and 17 controls, using flow cytometry (FC) and reverse transcription polymerase chain reaction (RT-PCR). In patients with NSCLC the epithelial cell compartment was significantly increased nd showed brighter CK-19 staining, compared to the control group. In NSCLC patients the immune compartment revealed an increased monocyte population and decreased lymphocyte subsets. The transcripts of CK- 19, CEA and EPCAM were higher in lung cancer patients and a positive correlation between these markers and the size of the primary lesion was also found. We concluded that the identification of CK-19, CEA and EPCAM in endobronchial ultrasound samples, using RT-PCR and FC was feasible and might aid in the detection of NSCLC lymph node metastases. The fourth study involved the combination of the radial endobronchial ultrasound with the cryoprobe for diagnosing solid peripheral lung lesions. We determined the feasibility, diagnostic yield, sample size and safety of the method. Lesions less than 40mm were located by ultrasound and forceps or cryobiopsies were performed in a randomized order. Of the 39 cases included, the lesion could be visualized by the miniprobe in 31 patients (79.5%), and lung cancer prevalence was 80.6%. The diagnostic yield of the biopsy forceps was 61.3% and for the cryobiopsy was 74.2 %. Cryobiopsies were significantly larger than forceps biopsies (11.17mm2 vs. 4.69mm2, p<0.001). There was only one case of moderate bleeding that was controlled by conservative measures. Transbronchial cryobiopsies under radial endobronchial ultrasound guidance were safe and effective in obtaining histological samples. The fifth study determined the diagnostic value of transthoracic sonography in predicting malignancy in patients with an undiagnosed pleural effusion. One hundred and fifty four patients were prospectively scanned. Relevant ultrasound images and videos were generated by an operator blinded to clinical and radiological results. These were subsequently visualized, its characteristics classified by independent reviewers and compared to the final diagnosis. A malignant pleural effusion was diagnosed in 66 cases (68.2 % with lung cancer) and a benign effusion in 67 cases. Thoracic ultrasound had a sensitivity of 80.3 %, specificity of 83.6%, negative predictive value of 81.2 % and positive predictive value of 82.8% to detect malignancy. The presence of pleural or diaphragmatic nodularity, pleural thickening greater than 10mm and swirling signal were significantly different (p<0.001 ), being suggestive of malignant effusion. The existence of pleural nodularity and absence of lung air bronchogram were more likely to indicate malignancy (OR 29.0 and OR 10.4, respectively). Transthoracic ultrasonography permits the distinction between malignant and benign pleural effusions. Pleural nodules were the most relevant feature. In conclusion, the results of this thesis provide a better understanding of the role of endobronchial ultrasound (linear and radial) and transthoracic sonography in lung cancer diagnosis and staging, with direct implications and applicability in clinical practice.
Resumo:
Eradication of code smells is often pointed out as a way to improve readability, extensibility and design in existing software. However, code smell detection remains time consuming and error-prone, partly due to the inherent subjectivity of the detection processes presently available. In view of mitigating the subjectivity problem, this dissertation presents a tool that automates a technique for the detection and assessment of code smells in Java source code, developed as an Eclipse plugin. The technique is based upon a Binary Logistic Regression model that uses complexity metrics as independent variables and is calibrated by expert‟s knowledge. An overview of the technique is provided, the tool is described and validated by an example case study.
Resumo:
Breast cancer is the most common type of cancer worldwide. The effectiveness of its treatment depends on early stage detection, as well as on the accuracy of its diagnosis. Recently, diagnosis techniques have been submitted to relevant breakthroughs with the upcoming of Magnetic Resonance Imaging, Ultrasound Sonograms and Positron Emission Tomography (PET) scans, among others. The work presented here is focused on studying the application of a PET system to a Positron Emission Mammography (PEM) system. A PET/PEM system works under the principle that a scintillating crystal will detect a gamma-ray pulse, originated at the cancerous cells, converting it into a correspondent visible light pulse. The latter must then be converted into an electrical current pulse by means of a Photo- -Sensitive Device (PSD). After the PSD there must be a Transimpedance Amplifier (TIA) in order to convert the current pulse into a suitable output voltage, in a time period lower than 40 ns. In this Thesis, the PSD considered is a Silicon Photo-Multiplier (SiPM). The usage of this recently developed type of PSD is impracticable with the conventional TIA topologies, as it will be proven. Therefore, the usage of the Regulated Common-Gate (RCG) topology will be studied in the design of the amplifier. There will be also presented two RCG variations, comprising a noise response improvement and differential operation of the circuit. The mentioned topology will also be tested in a Radio-Frequency front-end, showing the versatility of the RCG. A study comprising a low-voltage self-biasing feedback TIA will also be shown. The proposed circuits will be simulated with standard CMOS technology (UMC 130 nm), using a 1.2 V power supply. A power consumption of 0.34 mW with a signal-to-noise ratio of 43 dB was achieved.
Resumo:
Nowadays, existing 3D scanning cameras and microscopes in the market use digital or discrete sensors, such as CCDs or CMOS for object detection applications. However, these combined systems are not fast enough for some application scenarios since they require large data processing resources and can be cumbersome. Thereby, there is a clear interest in exploring the possibilities and performances of analogue sensors such as arrays of position sensitive detectors with the final goal of integrating them in 3D scanning cameras or microscopes for object detection purposes. The work performed in this thesis deals with the implementation of prototype systems in order to explore the application of object detection using amorphous silicon position sensors of 32 and 128 lines which were produced in the clean room at CENIMAT-CEMOP. During the first phase of this work, the fabrication and the study of the static and dynamic specifications of the sensors as well as their conditioning in relation to the existing scientific and technological knowledge became a starting point. Subsequently, relevant data acquisition and suitable signal processing electronics were assembled. Various prototypes were developed for the 32 and 128 array PSD sensors. Appropriate optical solutions were integrated to work together with the constructed prototypes, allowing the required experiments to be carried out and allowing the achievement of the results presented in this thesis. All control, data acquisition and 3D rendering platform software was implemented for the existing systems. All these components were combined together to form several integrated systems for the 32 and 128 line PSD 3D sensors. The performance of the 32 PSD array sensor and system was evaluated for machine vision applications such as for example 3D object rendering as well as for microscopy applications such as for example micro object movement detection. Trials were also performed involving the 128 array PSD sensor systems. Sensor channel non-linearities of approximately 4 to 7% were obtained. Overall results obtained show the possibility of using a linear array of 32/128 1D line sensors based on the amorphous silicon technology to render 3D profiles of objects. The system and setup presented allows 3D rendering at high speeds and at high frame rates. The minimum detail or gap that can be detected by the sensor system is approximately 350 μm when using this current setup. It is also possible to render an object in 3D within a scanning angle range of 15º to 85º and identify its real height as a function of the scanning angle and the image displacement distance on the sensor. Simple and not so simple objects, such as a rubber and a plastic fork, can be rendered in 3D properly and accurately also at high resolution, using this sensor and system platform. The nip structure sensor system can detect primary and even derived colors of objects by a proper adjustment of the integration time of the system and by combining white, red, green and blue (RGB) light sources. A mean colorimetric error of 25.7 was obtained. It is also possible to detect the movement of micrometer objects using the 32 PSD sensor system. This kind of setup offers the possibility to detect if a micro object is moving, what are its dimensions and what is its position in two dimensions, even at high speeds. Results show a non-linearity of about 3% and a spatial resolution of < 2µm.
Resumo:
Part of this thesis will be published in the following: Gomes, B.C., Santos, B. 2015. Methods for studying microRNAs expression and their targets in formalin-fixed, paraffin-embedded (FFPE) breast cancer tissues. In Methods in Molecular Biology: Cancer Drug Resistance (Rueff, J. & Rodrigues, A.S. eds), Springer Protocols.
Resumo:
The main objective of this thesis was the development of a gold nanoparticle-based methodology for detection of DNA adducts as biomarkers, to try and overcome existing drawbacks in currently employed techniques. For this objective to be achieved, the experimental work was divided in three components: sample preparation, method of detection and development of a model for exposure to acrylamide. Different techniques were employed and combined for de-complexation and purification of DNA samples (including ultrasonic energy, nuclease digestion and chromatography), resulting in a complete protocol for sample treatment, prior to detection. The detection of alkylated nucleotides using gold nanoparticles was performed by two distinct methodologies: mass spectrometry and colorimetric detection. In mass spectrometry, gold nanoparticles were employed for laser desorption/ionisation instead of the organic matrix. Identification of nucleotides was possible by fingerprint, however no specific mass signals were denoted when using gold nanoparticles to analyse biological samples. An alternate method using the colorimetric properties of gold nanoparticles was employed for detection. This method inspired in the non-cross-linking assay allowed the identification of glycidamide-guanine adducts and DNA adducts generated in vitro. For the development of a model of exposure, two different aquatic organisms were studies: a goldfish and a mussel. Organisms were exposed to waterborne acrylamide, after which mortality was recorded and effect concentrations were estimated. In goldfish, both genotoxicity and metabolic alterations were assessed and revealed dose-effect relationships of acrylamide. Histopathological alterations were verified primarily in pancreatic cells, but also in hepatocytes. Mussels showed higher effect concentrations than goldfish. Biomarkers of oxidative stress, biotransformation and neurotoxicity were analysed after prolonged exposure, showing mild oxidative stress in mussel cells, and induction of enzymes involved in detoxification of oxygen radicals. A qualitative histopathological screening revealed gonadotoxicity in female mussels, which may present some risk to population equilibrium.
Resumo:
This study analyses financial data using the result characterization of a self-organized neural network model. The goal was prototyping a tool that may help an economist or a market analyst to analyse stock market series. To reach this goal, the tool shows economic dependencies and statistics measures over stock market series. The neural network SOM (self-organizing maps) model was used to ex-tract behavioural patterns of the data analysed. Based on this model, it was de-veloped an application to analyse financial data. This application uses a portfo-lio of correlated markets or inverse-correlated markets as input. After the anal-ysis with SOM, the result is represented by micro clusters that are organized by its behaviour tendency. During the study appeared the need of a better analysis for SOM algo-rithm results. This problem was solved with a cluster solution technique, which groups the micro clusters from SOM U-Matrix analyses. The study showed that the correlation and inverse-correlation markets projects multiple clusters of data. These clusters represent multiple trend states that may be useful for technical professionals.
Resumo:
A transimpedance amplifier (TIA) is used, in radiation detectors like the positron emission tomography(PET), to transform the current pulse produced by a photo-sensitive device into an output voltage pulse with a desired amplitude and shape. The TIA must have the lowest noise possible to maximize the output. To achieve a low noise, a circuit topology is proposed where an auxiliary path is added to the feedback TIA input, In this auxiliary path a differential transconductance block is used to transform the node voltage in to a current, this current is then converted to a voltage pulse by a second feedback TIA complementary to the first one, with the same amplitude but 180º out of phase with the first feedback TIA. With this circuit the input signal of the TIA appears differential at the output, this is used to try an reduced the circuit noise. The circuit is tested with two different devices, the Avalanche photodiodes (APD) and the Silicon photomultiplier (SIPMs). From the simulations we find that when using s SIPM with Rx=20kΩ and Cx=50fF the signal to noise ratio is increased from 59 when using only one feedback TIA to 68.3 when we use an auxiliary path in conjunction with the feedback TIA. This values where achieved with a total power consumption of 4.82mv. While the signal to noise ratio in the case of the SIPM is increased with some penalty in power consumption.
Resumo:
As the complexity of markets and the dynamicity of systems evolve, the need for interoperable systems capable of strengthening enterprise communication effectiveness increases. This is particularly significant when it comes to collaborative enterprise networks, like manufacturing supply chains, where several companies work, communicate, and depend on each other, in order to achieve a specific goal. Once interoperability is achieved, that is once all network parties are able to communicate with and understand each other, organisations are able to exchange information along a stable environment that follows agreed laws. However, as markets adapt to new requirements and demands, an evolutionary behaviour is triggered giving space to interoperability problems, thus disrupting the sustainability of interoperability and raising the need to develop monitoring activities capable of detecting and preventing unexpected behaviour. This work seeks to contribute to the development of monitoring techniques for interoperable SOA-based enterprise networks. It focuses on the automatic detection of harmonisation breaking events during real-time communications, and strives to develop and propose a methodological approach to handle these disruptions with minimal or no human intervention, hence providing existing service-based networks with the ability to detect and promptly react to interoperability issues.
Resumo:
RESUMO: A infecção por H. pylori, enquadra-se nas doenças infecciosas gastroduodenais e estima-se que mais de 50% da população mundial esteja infectada. A história natural da infecção por H. pylori, sofre interferências relacionadas com a genética do hospedeiro, a estirpe e as características da toxicidade da bactéria. Associam-se a estes factores, o tempo de exposição à infecção, assim como as condições sociais e higiéno-sanitárias. Paralelamente, o H. pylori é considerado o principal agente patogénico das doenças gastroduodenais. Este estudo teve como objectivo principal caracterizar a infecção por H. pylori em populações de Angola e sua avaliação como problema de Saúde Pública. Trata-se de um estudo prospectivo dirigido a dois grupos populacionais, um constituído por indivíduos aparentemente saudáveis, sem queixas gástricas específicas, em ambiente de comunidade, Grupo I, e outro, Grupo II, constituído por doentes que acorreram ao serviço de Gastrenterologia do Hospital Militar Principal de Luanda (HMP). No que diz respeito ao estudo na comunidade a pesquisa de H. pylori foi realizada pelo método ELISA de pesquisa de antigénios nas fezes. Por sua vez, a nível hospitalar, os métodos de diagnóstico da infecção por H. pylori foram: a endoscopia digestiva alta para a colheita de biópsias da mucosa gástrica destinadas ao exame anatomopatológico, ao exame citobacteriológico e aos métodos moleculares. Como método não invasivos foi utilizado o teste respiratório com ureia marcada. Grupo I: o diagnóstico da infecção por H. pylori, realizado pela pesquisa de antigénios deste microrganismo nas fezes, revelou uma frequência de 69,6% na população em estudo. Considerando em cada região, verificou-se que a região do Sambizanga possuía o valor mais elevado de frequência, 81,2%, seguida do Dinge com 79,5%, estatisticamente significativas (p 0,001). A avaliação da distribuição da frequência da infecção por grupo etário, revelou que os indivíduos com idade inferior a 15 anos, possuíam uma frequência de infecção de 63,5% e sendo de 76% nos indivíduos com idade superior a 15 anos. Este estudo permitiu concluir que a frequência da infecção por H. pylori nas regiões estudadas, é de 70% à excepção do Capulo, zona litoral em que não obstante as precárias condições de saneamento, a frequência da infecção por H. pylori é baixa. Grupo II: dos 309 doentes avaliados, verificou-se que 22 (7%), apresentavam uma mucosa normal e 287 (93%) uma mucosa alterada. A avaliação histológica das biópsias do antro, em 270 amostras de acordo com o Sistema de Sidney, em 235 (87,0%), revelou a presença de gastrite, 13 (4,8%) a presença de úlcera e em 9 (3,3%), uma lesão tumoral. A avaliação histológica da actividade nas 226 amostras do antro gástrico, verificou-se que 129 (57%) possuíam actividade e 97 (43%) não possuíam. O estudo das 255 biópsias do corpo, revelou em 212 (83,1%), a presença de lesões de gastrite, em 7 (2,7%), observaram-se lesões tumorais e 2 (0.8%) apresentaram úlcera. Dos 263 doentes avaliados histologicamente para pesquisa do H. pylori, 148 (58,2%) revelaram a presença positiva desta bactéria e 106 (41,7%) foram negativas. No que diz respeito à susceptibilidade aos macrólidos, do universo de 158 doentes com H. pylori positivo, 125 (79,1%) doentes apresentaram estirpes sensíveis aos macrólidos e 33 (20,9%) estirpes resistentes. Em relação aos factores de virulência, na avaliação conjunta dos dois factores de virulência estudados (cagA e vacA), em relação ao tipo de lesões encontradas na mucosa gástrica, verificou-se que dos 11 doentes com úlcera, 7 (63,6%), apresentavam uma estirpe cagA negativa, sendo 6 vacA s1 (85,7%), uma s2 e 4 (36,3%) com uma estirpe cagA positiva e vacA s1. Por sua vez dos 2 doentes com tumor, ambas as estirpes eram cagA negativas, sendo uma vacA s1 e outra vacA s2. Em relação aos factores de virulência nos doentes aos quais se diagnosticou úlcera e tumor apresentavam estirpe cagA negativa, vacAs1. Em relação ás lesões gástricas inflamatórias, os doentes com gastrite apresentavam cagA positivo. Do presente trabalho, em atenção aos resultados obtidos no que concerne a prevalência em populações sem queixas gastrenterológicas, recomenda-se que o mesmo se possa vir a replicar numa abrangência maior, realizando-se, por exemplo, estudos comparativos de prevalência entre as populações residentes no litoral (beira-mar) e as do interior. Pelas características genotípicas de H. pylori, em correspondência com as lesões encontradas, após novos estudos mais abrangentes, recomenda-se a avaliação de uma terapêutica mais acessível para o doente e que seja de maior eficácia. Face à escassez de médicos especialistas em gastrenterologia em Angola e de meios de diagnóstico, recomenda-se um estudo mais alargado da eficácia do seguimento do doente dispéptico, conforme protocolo avaliado pelo Colégio da Especialidade de Gastrenterologia da Ordem dos Médicos de Angola e já em prática em algumas instituições de saúde.--------------------------- ABSTRACT: H.pylori infection, is part of the gastroduodenal infectious diseases and it is estimated that over 50% of the world population is infected. The natural history of H.pylori infection, is influenced by host genetic, strain type, of bacterial virulence factors, time of exposure to the infection, as well as social and hygienic-sanitary conditions. In parallel, H.pylori is considered the main pathogen of gastroduodenal diseases. This study's main objective was to characterize H.pylori infection in populations of Angola and its evaluation as a public health problem. This is a prospective study conducted in two population groups, one in community environment composed by healthy individuals without specific gastric complaints - Group I, and Group II consisting of patients who went to the Gastroenterology Service of the Hospital Military of Luanda (HMP). As regards to the study in the community detection of H.pylori was carried out by antigen search in faeces using ELISA method. At hospital level H.pylori infection diagnostic methods were: upper gastrointestinal endoscopy to obtain gastric mucosal biopsies for histology, culture and molecular methods. As a non-invasive breath test with labelled urea was used. Group I: the diagnosis of H.pylori infection, by antigens detection in faeces, revealed a frequency of 69.6% in the study population. Whereas in each region, it was found that the Sambizanga region had the highest frequency of positive cases, 81.2% , followed by Dinge with 79.5%, Funda with 78.7 and Capulo with 39.8% being differences statistically significant (p=0.001). The evaluation of the distribution of the infection frequency by age group, revealed that individuals younger than 15 years had a frequency of 63.5% and in individuals older than 15 years, 76%. This study showed that the frequency of H.pylori infection in the regions studied was 70% exception due to Capulo, a coastal zone where despite the poor sanitation conditions; the frequency of H.pylori infection is lower. Group II: from the 309 patients evaluated, it was found that 22 (7%) had a normal mucosa and 287 (93%) a modified mucosa. Histological evaluation of antrum biopsies in 270 samples according to the Sydney System revealed the presence of gastritis in 235 (87.0%), the presence of ulcers in 13 (4.8%) and a tumour in 9 (3 3%). Histological assessment of activity in the gastric antrum of 226 samples, revealed that 129 (57%) had activity and 97 (43%) did not. The evaluation of the 255 corpus biopsies showed in 212 (83.1%), the presence of lesions of gastritis, in 7 (2.7%) tumour lesions and in 2 (0.8%) an ulcer. Of the 263 patients histological evaluated for H.pylori, 148 (58.2%) revealed the presence of this bacteria and 106 (41.7%) were negative. As regards susceptibility to macrolides from the universe of 158 patients with H.pylori, 125 (79.1%) patients had macrolides susceptible strains and 33 (20.9%) resistant strains. Regarding virulence factors (vacA and cagA), it was found that from the 11 patients with ulcers, 7 (63.6%), had a cagA negative strain, being 6 vacA s1, (85.7%) one vacA s2 and 4 (36.3%) with a cagA positive strain vacA s1. Concerning the 2 patients with tumour, both strains were cagA negative, one vacA s1 and other vacA s2. Patients with ulcer and tumour had cagA negative strains vacAs1. From this work, considering the prevalence of H.pylori obtained in health population, it is recommended that the same study should be performed in larger scale to confirm these results. The results of H.pylori genotyping suggest that more comprehensive studies are needed. Given the reduce number gastroenterology specialist in Angola and the lack of diagnostics methods, we recommend a larger study of the effectiveness of follow-up the patient dyspeptic, according to the protocol assessed by the College of Gastroenterology Specialty of the Order of Doctors and Angola already in place in some health institutions.
Resumo:
In cataract surgery, the eye’s natural lens is removed because it has gone opaque and doesn’t allow clear vision any longer. To maintain the eye’s optical power, a new artificial lens must be inserted. Called Intraocular Lens (IOL), it needs to be modelled in order to have the correct refractive power to substitute the natural lens. Calculating the refractive power of this substitution lens requires precise anterior eye chamber measurements. An interferometry equipment, the AC Master from Zeiss Meditec, AG, was in use for half a year to perform these measurements. A Low Coherence Interferometry (LCI) measurement beam is aligned with the eye’s optical axis, for precise measurements of anterior eye chamber distances. The eye follows a fixation target in order to make the visual axis align with the optical axis. Performance problems occurred, however, at this step. Therefore, there was a necessity to develop a new procedure that ensures better alignment between the eye’s visual and optical axes, allowing a more user friendly and versatile procedure, and eventually automatizing the whole process. With this instrument, the alignment between the eye’s optical and visual axes is detected when Purkinje reflections I and III are overlapped, as the eye follows a fixation target. In this project, image analysis is used to detect these Purkinje reflections’ positions, eventually automatically detecting when they overlap. Automatic detection of the third Purkinje reflection of an eye following a fixation target is possible with some restrictions. Each pair of detected third Purkinje reflections is used in automatically calculating an acceptable starting position for the fixation target, required for precise measurements of anterior eye chamber distances.
Resumo:
Circulating tumor cells (CTCs) may induce metastases when detached from the primary tumor. The numbers of these cells in blood offers a valuable prognostic indication. Magnetoresistive sensing is an attractive option for CTC counting. In this technique, cells are labeled with nancomposite polymer beads that provide the magnetic signal. Bead properties such as size and magnetic content must be optimized in order to be used as a detection tool in a magnetoresistive platform. Another important component of the platform is the magnet required for proper sensing. Both components are addressed in this work. Nanocomposite polymer beads were produced by nano-emulsion and membrane emulsification. Formulations of the oil phase comprising a mixture of aromatic monomers and iron oxide were employed. The effect of emulsifier (surfactant) concentration on bead size was studied. Formulations of polydimethilsiloxane (PDMS) with different viscosities were also prepared with nano-emulsion method resulting in colloidal beads. Polycaprolactone (PCL) beads were also synthetized by the membrane emulsification method. The beads were characterized by different techiques such as dynamic light scattering (DLS), thermogravimetric analysis (TGA) and scanning electron microscopy (SEM). Additionally, the magnet dimensions of the platform designed to detect CTCs were optimized through a COMSOL multiphysics simulation.
Resumo:
Remote sensing - the acquisition of information about an object or phenomenon without making physical contact with the object - is applied in a multitude of different areas, ranging from agriculture, forestry, cartography, hydrology, geology, meteorology, aerial traffic control, among many others. Regarding agriculture, an example of application of this information is regarding crop detection, to monitor existing crops easily and help in the region’s strategic planning. In any of these areas, there is always an ongoing search for better methods that allow us to obtain better results. For over forty years, the Landsat program has utilized satellites to collect spectral information from Earth’s surface, creating a historical archive unmatched in quality, detail, coverage, and length. The most recent one was launched on February 11, 2013, having a number of improvements regarding its predecessors. This project aims to compare classification methods in Portugal’s Ribatejo region, specifically regarding crop detection. The state of the art algorithms will be used in this region and their performance will be analyzed.