37 resultados para Static Mixer
Resumo:
Rupture of aortic aneurysms (AA) is a major cause of death in the Western world. Currently, clinical decision upon surgical intervention is based on the diameter of the aneurysm. However, this method is not fully adequate. Noninvasive assessment of the elastic properties of the arterial wall can be a better predictor for AA growth and rupture risk. The purpose of this study is to estimate mechanical properties of the aortic wall using in vitro inflation testing and 2D ultrasound (US) elastography, and investigate the performance of the proposed methodology for physiological conditions. Two different inflation experiments were performed on twelve porcine aortas: 1) a static experiment for a large pressure range (0 – 140 mmHg); 2) a dynamic experiment closely mimicking the in vivo hemodynamics at physiological pressures (70 – 130 mmHg). 2D raw radiofrequency (RF) US datasets were acquired for one longitudinal and two cross-sectional imaging planes, for both experiments. The RF-data were manually segmented and a 2D vessel wall displacement tracking algorithm was applied to obtain the aortic diameter–time behavior. The shear modulus G was estimated assuming a Neo-Hookean material model. In addition, an incremental study based on the static data was performed to: 1) investigate the changes in G for increasing mean arterial pressure (MAP), for a certain pressure difference (30, 40, 50 and 60 mmHg); 2) compare the results with those from the dynamic experiment, for the same pressure range. The resulting shear modulus G was 94 ± 16 kPa for the static experiment, which is in agreement with literature. A linear dependency on MAP was found for G, yet the effect of the pressure difference was negligible. The dynamic data revealed a G of 250 ± 20 kPa. For the same pressure range, the incremental shear modulus (Ginc) was 240 ± 39 kPa, which is in agreement with the former. In general, for all experiments, no significant differences in the values of G were found between different image planes. This study shows that 2D US elastography of aortas during inflation testing is feasible under controlled and physiological circumstances. In future studies, the in vivo, dynamic experiment should be repeated for a range of MAPs and pathological vessels should be examined. Furthermore, the use of more complex material models needs to be considered to describe the non-linear behavior of the vascular tissue.
Resumo:
Most of today’s systems, especially when related to the Web or to multi-agent systems, are not standalone or independent, but are part of a greater ecosystem, where they need to interact with other entities, react to complex changes in the environment, and act both over its own knowledge base and on the external environment itself. Moreover, these systems are clearly not static, but are constantly evolving due to the execution of self updates or external actions. Whenever actions and updates are possible, the need to ensure properties regarding the outcome of performing such actions emerges. Originally purposed in the context of databases, transactions solve this problem by guaranteeing atomicity, consistency, isolation and durability of a special set of actions. However, current transaction solutions fail to guarantee such properties in dynamic environments, since they cannot combine transaction execution with reactive features, or with the execution of actions over domains that the system does not completely control (thus making rolling back a non-viable proposition). In this thesis, we investigate what and how transaction properties can be ensured over these dynamic environments. To achieve this goal, we provide logic-based solutions, based on Transaction Logic, to precisely model and execute transactions in such environments, and where knowledge bases can be defined by arbitrary logic theories.
Resumo:
In this thesis a CMOS low-power and low-voltage RF receiver front-end is presented. The main objective is to design this RF receiver so that it can be powered by a piezoelectric energy harvesting power source, included in a Wireless Sensor Node application. For this type of applications the major requirements are: the low-power and low-voltage operation, the reduced area and cost and the simplicity of the architecture. The system key blocks are the LNA and the mixer, which are studied and optimized with greater detail, achieving a good linearity, a wideband operation and a reduced introduction of noise. A wideband balun LNA with noise and distortion cancelling is designed to work at a 0.6 V supply voltage, in conjunction with a double-balanced passive mixer and subsequent TIA block. The passive mixer operates in current mode, allowing a minimal introduction of voltage noise and a good linearity. The receiver analog front-end has a total voltage conversion gain of 31.5 dB, a 0.1 - 4.3 GHz bandwidth, an IIP3 value of -1.35 dBm, and a noise figure lower than 9 dB. The total power consumption is 1.9 mW and the die area is 305x134.5 m2, using a standard 130 nm CMOS technology.
Resumo:
In the context of this dissertation several studies were developed resulting in submission and publication “Evaluation of mechanical soft-abrasive blasting and chemical cleaning methods on alkyd-paint graffiti made on calcareous stones” to Journal of Cultural Heritage. (http://dx.doi.org/10.101 /j.culher.2014.10.004)
Resumo:
Evidence in the literature suggests a negative relationship between volume of medical procedures and mortality rates in the health care sector. In general, high-volume hospitals appear to achieve lower mortality rates, although considerable variation exists. However, most studies focus on US hospitals, which face different incentives than hospitals in a National Health Service (NHS). In order to add to the literature, this study aims to understand what happens in a NHS. Results reveal a statistically significant correlation between volume of procedures and better outcomes for the following medical procedures: cerebral infarction, respiratory infections, circulatory disorders with AMI, bowel procedures, cirrhosis, and hip and femur procedures. The effect is explained with the practice-makes-perfect hypothesis through static effects of scale with little evidence of learning-by-doing. The centralization of those medical procedures is recommended given that this policy would save a considerable number of lives (reduction of 12% in deaths for cerebral infarction).
Resumo:
Quadrature oscillators are key elements in modern radio frequency (RF) transceivers and very useful nowadays in wireless communications, since they can provide: low quadrature error, low phase-noise, and wide tuning range (useful to cover several bands). RC oscillators can be fully integrated without the need of external components (external high Q-inductors), optimizing area, cost, and power consumption. The conventional structure of ring oscillator offers poor frequency stability and phasenoise, low quality factor (Q), and besides being vulnerable to process, voltage and temperature (PVT) variations, its performance degrades as the frequency of operation increases. This thesis is devoted to quadrature oscillators and presents a detailed comparative study of ring oscillator and shift register (SR) approaches. It is shown that in SRs both phase-noise and phase error are reduced, while ring oscillators have the advantage of occupying less area and less consumption due to the reduced number of components in the circuit. Thus, although ring oscillators are more suitable for biomedical applications, SRs are more appropriate for wireless applications, especially when specification requirements are more stringent and demanding. The first architecture studied consists in a simple CMOS ring oscillator employing an odd number of static single-ended inverters as delay cells. Subsequently, the quadrature 4-stage ring oscillator concept is shown and post-layout simulations are presented. The 3 and 4-phase single-frequency local oscillator (LO) generators employing SRs are presented, the latter with 50% and 25% duty-cycles. The circuits operate at 600 MHz and 900 MHz, and were designed in a 130 nm standard CMOS technology with a voltage supply of 1.2 V.
Resumo:
RESUMO - A dor, incómodo ou desconforto ao nível músculo-esquelético, sobretudo devido a situações e/ou postos de trabalho com elevadas exigências ao nível postural, de aplicação de força, de repetitividade ou por incorrecta distribuição das pausas, é aceite como um indicador de situações de risco passíveis de se encontrarem na génese de lesões músculo- -esqueléticas ligadas ao trabalho (LMELT) (Stuart-Buttle, 1994). No sentido de avaliar a prevalência de sintomas de LME, efectuou-se um estudo numa grande empresa da indústria de componentes para automóveis na região de Lisboa durante o ano de 2001. Utilizou-se um instrumento de recolha de informação construído a partir de uma adaptação do questionário nórdico músculo-esquelético (QNM) (Kuorinka et al., 1987). Com o apoio do serviço de saúde ocupacional da referida empresa, o questionário foi entregue a todos os trabalhadores, obtendo-se uma taxa de respondentes de 63,2% (n = 574). A população em estudo é maioritariamente do sexo feminino (83,9%), tem idades compreendidas entre os 18 e os 65 anos e a classe modal situa-se entre os 26 e os 33 anos (23,3%). Os resultados evidenciam uma alta prevalência de sintomatologia de LME e diferenças significativas de sintomas entre as categorias profissionais (1) operadores de máquina de costura, (2) trabalhadores dos armazéns e de transporte de mercadorias e (3) trabalhadores da logística, qualidade e escritórios. Os operadores apresentam índices superiores e diferentes (p < 0,05) de sintomatologia nos últimos doze meses ao nível da região cervical, ombros, cotovelos, ancas/coxas, pernas/joelhos e tornozelos/pés e nos punhos nos últimos sete dias. No presente estudo, a análise dos dados obtidos parece indicar que a natureza e as características da actividade de trabalho do grupo profissional operadores de máquina de costura (flexão cervical > 20°, trabalho muscular predominantemente estático ao nível da articulação dos ombros, elevação dos membros superiores > 45°, ortostatismo e exigências elevadas ao nível dos punhos/mãos) estão implicadas no desencadear da sintomatologia auto- -referida.