28 resultados para Moderate resolution imaging spectroradiometer


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertation presented at Faculdade de Ciências e Tecnologia Universidade Nova de Lisboa to obtain a Master Degree in Biomedical Engineering

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia Electrotécnica e de Computadores

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Biotecnologia

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para a obtenção do Grau de Mestre em Engenharia Biomédica

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nowadays, existing 3D scanning cameras and microscopes in the market use digital or discrete sensors, such as CCDs or CMOS for object detection applications. However, these combined systems are not fast enough for some application scenarios since they require large data processing resources and can be cumbersome. Thereby, there is a clear interest in exploring the possibilities and performances of analogue sensors such as arrays of position sensitive detectors with the final goal of integrating them in 3D scanning cameras or microscopes for object detection purposes. The work performed in this thesis deals with the implementation of prototype systems in order to explore the application of object detection using amorphous silicon position sensors of 32 and 128 lines which were produced in the clean room at CENIMAT-CEMOP. During the first phase of this work, the fabrication and the study of the static and dynamic specifications of the sensors as well as their conditioning in relation to the existing scientific and technological knowledge became a starting point. Subsequently, relevant data acquisition and suitable signal processing electronics were assembled. Various prototypes were developed for the 32 and 128 array PSD sensors. Appropriate optical solutions were integrated to work together with the constructed prototypes, allowing the required experiments to be carried out and allowing the achievement of the results presented in this thesis. All control, data acquisition and 3D rendering platform software was implemented for the existing systems. All these components were combined together to form several integrated systems for the 32 and 128 line PSD 3D sensors. The performance of the 32 PSD array sensor and system was evaluated for machine vision applications such as for example 3D object rendering as well as for microscopy applications such as for example micro object movement detection. Trials were also performed involving the 128 array PSD sensor systems. Sensor channel non-linearities of approximately 4 to 7% were obtained. Overall results obtained show the possibility of using a linear array of 32/128 1D line sensors based on the amorphous silicon technology to render 3D profiles of objects. The system and setup presented allows 3D rendering at high speeds and at high frame rates. The minimum detail or gap that can be detected by the sensor system is approximately 350 μm when using this current setup. It is also possible to render an object in 3D within a scanning angle range of 15º to 85º and identify its real height as a function of the scanning angle and the image displacement distance on the sensor. Simple and not so simple objects, such as a rubber and a plastic fork, can be rendered in 3D properly and accurately also at high resolution, using this sensor and system platform. The nip structure sensor system can detect primary and even derived colors of objects by a proper adjustment of the integration time of the system and by combining white, red, green and blue (RGB) light sources. A mean colorimetric error of 25.7 was obtained. It is also possible to detect the movement of micrometer objects using the 32 PSD sensor system. This kind of setup offers the possibility to detect if a micro object is moving, what are its dimensions and what is its position in two dimensions, even at high speeds. Results show a non-linearity of about 3% and a spatial resolution of < 2µm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RESUMO: Apesar de toda a evolução farmacológica e de meios complementares de diagnóstico possível nos últimos anos, o enfarte agudo do miocárdio e a morte súbita continuam a ser a primeira manifestação da aterosclerose coronária para muitos doentes, que estavam previamente assintomáticos. Os exames complementares de diagnóstico tradicionalmente usados para avaliar a presença de doença coronária, baseiam‐se na documentação de isquémia do miocárdio e por este motivo a sua positividade depende da presença de lesões coronárias obstrutivas. As lesões coronárias não obstrutivas estão também frequentemente implicadas no desenvolvimento de eventos coronários. Apesar de o risco absoluto de instabilização por placa ser superior para as lesões mais volumosas e obstrutivas, estas são menos prevalentes do que as placas não obstrutivas e assim, por questões probabilísticas, os eventos coronários resultam com frequência da rotura ou erosão destas últimas. Estudos recentes de imagiologia intracoronária avançada forneceram evidência de que apesar de ser possível identificar algumas características de vulnerabilidade em placas associadas ao desenvolvimento subsequente de eventos coronários, a sua sensibilidade e especificidade é muito baixa para aplicação clínica. Mais do que o risco associado a uma placa em particular, para o doente poderá ser mais importante o risco global da sua árvore coronária reflexo da soma das probabilidade de todas as suas lesões, sendo que quanto maior for a carga aterosclerótica maior será o seu risco. A angio TC cardíaca é a mais recente técnica de imagem não invasiva para o estudo da doença coronária e surgiu nos últimos anos fruto de importantes avanços na tecnologia de TC multidetectores. Estes avanços, permitiram uma progressiva melhoria da resolução espacial e temporal, contribuindo para a melhoria da qualidade dos exames, bem como uma significativa redução da dose de radiação. A par desta evolução tecnológica, foi aumentando a experiência e gerada mais evidência científica, tornando a angio TC cardíaca cada vez mais robusta na avaliação da doença coronária e aumentando a sua aplicabilidade clínica. Mais recentemente apareceram vários trabalhos que validaram o seu valor prognóstico, assinalando a sua chegada à idade adulta. Para além de permitir excluir a presença de doença coronária e de identificar a presença de estenoses significativas, a angio TC cardíaca permite identificar a presença de lesões coronárias não obstrutivas, característica impar desta técnica como modalidade de imagem não invasiva. Ao permitir identificar a totalidade das lesões ateroscleróticas (obstrutivas e não obstrutivas), a 18 angio TC cardíaca poderá fornecer uma quantificação da carga aterosclerótica coronária total, podendo essa identificação ser útil na estratificação dos indivíduos em risco de eventos coronários. Neste trabalho foi possível identificar preditores demográficos e clínicos de uma elevada carga aterosclerótica coronária documentada pela angioTC cardíaca, embora o seu poder discriminativo tenha sido relativamente modesto, mesmo quando agrupados em scores clínicos. Entre os vários scores, o desempenho foi um pouco melhor para o score de risco cardiovascular Heartscore. Estas limitações espelham a dificuldade de prever apenas com base em variáveis clínicas, mesmo quando agrupadas em scores, a presença e extensão da doença coronária. Um dos factores de risco clássicos, a obesidade, parece ter uma relação paradoxal com a carga aterosclerótica, o que pode justificar algumas limitações da estimativa com base em scores clínicos. A diabetes mellitus, por outro lado, foi um dos preditores clínicos mais importantes, funcionando como modelo de doença coronária mais avançada, útil para avaliar o desempenho dos diferentes índices de carga aterosclerótica. Dada a elevada prevalência de placas ateroscleróticas identificáveis por angio TC na árvore coronária, torna-‐se importante desenvolver ferramentas que permitam quantificar a carga aterosclerótica e assim identificar os indivíduos que poderão eventualmente beneficiar de medidas de prevenção mais intensivas. Com este objectivo, foi desenvolvido um índice de carga aterosclerótica que reúne a informação global acerca da localização, do grau de estenose e do tipo de placa, obtida pela angio TC cardíaca, o CT--‐LeSc. Este score poderá vir a ser uma ferramenta útil para quantificação da carga aterosclerótica coronária, sendo de esperar que possa traduzir a informação prognóstica da angio TC cardíaca. Por fim, o conceito de árvore coronária vulnerável poderá ser mais importante do que o da placa vulnerável e a sua identificação pela angio TC cardíaca poderá ser importante numa estratégia de prevenção mais avançada. Esta poderá permitir personalizar as medidas de prevenção primária, doseando melhor a sua intensidade em função da carga aterosclerótica, podendo esta vir a constituir uma das mais importantes indicações da angio TC cardíaca no futuro.---------------- ABSTRACT Despite the significant advances made possible in recent years in the field of pharmacology and diagnostic tests, acute yocardial infarction and sudden cardiac death remain the first manifestation of coronary atherosclerosis in a significant proportion of patients, as many were previously asymptomatic. Traditionally, the diagnostic exams employed for the evaluation of possible coronary artery disease are based on the documentation of myocardial ischemia and, in this way, they are linked to the presence of obstructive coronary stenosis. Nonobstructive coronary lesions are also frequently involved in the development of coronary events. Although the absolute risk of becoming unstable per plaque is higher for more obstructive and higher burden plaques, these are much less frequent than nonobstructive lesions and therefore, in terms of probability for the patient, coronary events are often the result of rupture or erosion of the latter ones. Recent advanced intracoronary imaging studies provided evidence that although it is possible to identify some features of vulnerability in plaques associated with subsequente development of coronary events, the sensitivity and sensibility are very limited for clinical application. More important than the individual risk associated with a certain plaque, for the patient it might be more important the global risk of the total coronary tree, as reflected by the sum of the diferent probabilities of all the lesions, since the higher the coronary Atherosclerotic burden, the higher the risk for the patient. Cardiac CT or Coronary CT angiography is still a young modality. It is the most recente noninvasive imaging modality in the study of coronary artery disease and its development was possible due to important advances in multidetector CT technology. These allowed significant improvements in temporal and spatial resolution, leading to better image quality and also some impressive reductions in radiation dose. At the same time, the increasing experience with this technique lead to a growing body of scientific evidence, making cardiac CT a robust imaging tool for the evaluation of coronary artery disease and increased its clinical indications. More recently, several publications documented its prognostic value, marking the transition of cardiac CT to adulthood. Besides being able to exclude the presence of coronary artery disease and of obstructive lesions, Cardiac CT allows also the identification of nonobstructive lesions, making this a unique tool in the field of noninvasive imaging modalities. By evaluating both obstructive and nonobstructive lesions, cardiac CT can provide for the quantification of total coronary atherosclerotic burden, and this can be useful to stratify the risk of future coronary events. In the present work, it was possible to identify significant demographic and clinical predictors of a high coronary atherosclerotic burden as assessed by cardiac CT, but with modest odds ratios, even when the individual variables were gathered in clinical scores. Among these diferent clinical scores, the performance was better for the Heartscore, a cardiovascular risk score. This modest performance underline the limitations on predicting the presence and severity of coronary disease based only on clinical variables, even when optimized together in risk scores, One of the classical risk factors, obesity, had in fact a paradoxical relation with coronary atherosclerotic burden and might explain some of the limitations of the clinical models. On the opposite, diabetes mellitus was one of the strongest clinical predictors, and was considered to be a model of more advanced coronary disease, useful to evaluate the performance of diferent plaque burden scores. In face of the high prevalence of plaques that can be identified in the coronary tree of patients undergoing cardiac CT, it is of utmost importance to develop tools to quantify the total coronary atherosclerotic burden providing the identification of patients that could eventually benefit from more intensive preventive measures. This was the rational for the development of a coronary atherosclerotic burden score, reflecting the comprehensive information on localization, degree of stenosis and plaque composition provided by cardiac CT – the CT-LeSc. This score may become a useful tool to quantify total coronary atherosclerotic burden and is expected to convey the strong prognostic information of cardiac CT. Lastly, the concept of vulnerable coronary tree might become more important than the concept of the vulnerable plaque and his assessment by cardiac CT Might become important in a more advance primary prevention strategy. This Could lead to a more custom-made primary prevention, tailoring the intensity of preventive measures to the atherosclerotic burden and this might become one of the most important indications of cardiac CT In the near future.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Breast cancer is the most common type of cancer among women all over the world. An important issue that is not commonly addressed in breast cancer imaging literature is the importance of imaging the underarm region—where up to 80% of breast cancer cells can metastasise to. The first axillary lymph nodes to receive drainage from the primary tumour in the breast are called Sentinel Node. If cancer cells are found in the Sentinel Node, there is an increased risk of metastatic breast cancer which makes this evaluation crucial to decide what follow-up exams and therapy to follow. However, non-invasive detection of cancer cells in the lymph nodes is often inconclusive, leading to the surgical removal of too many nodes which causes adverse side-effects for patients. Microwave Imaging is one of the most promising non-invasive imaging modalities for breast cancer early screening and monitoring. This novel study tests the feasibility of imaging the axilla region by means of the simulation of an Ultra-Wideband Microwave Imaging system. Simulations of such system are completed in several 2D underarm models that mimic the axilla. Initial imaging results are obtained by means of processing the simulated backscattered signals by eliminating artefacts caused by the skin and beamforming the processed signals in order to time-align all the signals recorded at each antenna. In this dissertation several image formation algorithms are implemented and compared by visual inspection of the resulting images and through a range of performance metrics, such as Signal-to-Clutter Ratio and FullWidth Half Maximum calculations. The results in this study showed that Microwave Imaging is a promising technique that might allow to identify the presence and location of metastasised cancer cells in axillary lymph nodes, enabling the non-invasive evaluation of breast cancer staging.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diffusion Kurtosis Imaging (DKI) is a fairly new magnetic resonance imag-ing (MRI) technique that tackles the non-gaussian motion of water in biological tissues by taking into account the restrictions imposed by tissue microstructure, which are not considered in Diffusion Tensor Imaging (DTI), where the water diffusion is considered purely gaussian. As a result DKI provides more accurate information on biological structures and is able to detect important abnormalities which are not visible in standard DTI analysis. This work regards the development of a tool for DKI computation to be implemented as an OsiriX plugin. Thus, as OsiriX runs under Mac OS X, the pro-gram is written in Objective-C and also makes use of Apple’s Cocoa framework. The whole program is developed in the Xcode integrated development environ-ment (IDE). The plugin implements a fast heuristic constrained linear least squares al-gorithm (CLLS-H) for estimating the diffusion and kurtosis tensors, and offers the user the possibility to choose which maps are to be generated for not only standard DTI quantities such as Mean Diffusion (MD), Radial Diffusion (RD), Axial Diffusion (AD) and Fractional Anisotropy (FA), but also DKI metrics, Mean Kurtosis (MK), Radial Kurtosis (RK) and Axial Kurtosis (AK).The plugin was subjected to both a qualitative and a semi-quantitative analysis which yielded convincing results. A more accurate validation pro-cess is still being developed, after which, and with some few minor adjust-ments the plugin shall become a valid option for DKI computation

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RESUMO: Enthesitis is the hallmark of spondyloarthritis (SpA), and is observed in all subtypes. Wide information on SpA abnormalities, including synovitis, tendinitis and enthesitis, can be efficiently perceived by Doppler ultrasound. Furthermore, several studies on imaging of enthesis showed that imaging techniques are better than clinical examination to detect enthesis alterations; and vascularized enthesitis detected by Doppler ultrasound appears to be a valuable diagnostic tool to confirm SpA diagnosis. However, data published until now concerning entheseal elementary alterations that characterize SpA enthesitis (enthesis inflammatory activity) or enthesopathy (permanent structural changes) reflect rather the authors’ empiric opinion than a methodological validation process. In this sense it seems crucial to identify elementary entheseal lesions associated with activity or damage, in order to improve monitoring and treatment response in SpA patients. The development of better assessment tools is today a challenge and a need in SpA. The first study of this thesis focused on the analysis of the reliability of inter-lector and inter-ultrasonography equipment of Madrid sonography enthesitis index (MASEI). Fundamental data for the remaining unrolling project validity. In the second and third studies we concerned about two entheseal elemental lesions: erosions and bursa. In literature erosions represent a permanent structural damage, being useful for monitoring joint injury, disease activity and therapeutic response in many rheumatic diseases; and to date, this concept has been mostly applied in rheumatoid arthritis (RA). Unquestionably, erosion is a tissue-related damage and a structural change. However, the hypothesis that we decided to test was if erosions represent a permanent structural change that can only grow and worsen over time, as occurs in RA, or a transitory alteration. A longitudinal study of early SpA patients was undertaken, and the Achilles enthesis was used as a model. Our results strongly suggested that previously detected erosions could disappear during the course of the disease, being consistent with the dynamic behavior of erosion over time. Based on these striking results it seems reasonable to suggest that the new-bone formation process in SpA could be associated with the resolution of cortical entheseal erosion over time. These results could also be in agreement with the apparent failure of anti-tumor necrosis factor (TNF) therapies to control bone proliferation in SpA; and with the relation of TNF-α, Dickkopf-related protein 1 (Dkk-1) and the regulatory molecule of the Wnt signaling pathway in the bone proliferation in SpA. In the same model, we then proceeded to study the enthesis bursa. Interestingly, the Outcome Measures in Rheumatology Clinical Trials (OMERACT) enthesopathy definition does not include bursa as an elementary entheseal lesion. Nonetheless, bursa was included in 46% of the enthesis studies in a recently systematic literature review, being in agreement with the concept of “synovio-entheseal complex” that includes the link between enthesitis and osteitis in SpA. It has been clarified in recent data that there is not only a close functional integration of the enthesis with the neighboring bone, but also a connection between enthesitis and synovitis. Therefore, we tried to assess the prevalence and relevance of the bursa-synovial lesion in SpA. Our findings showed a significant increase of Achilles bursa presence and thickness in SpA patients compared to controls (healthy/mechanical controls and RA controls). These results raise awareness to the need to improve the enthesopathy ultrasonographic definition. In the final work of this thesis, we have explored new perspectives, not previously reported, about construct validity of enthesis ultrasound as a possible activity outcome in SpA. We performed a longitudinal Achilles enthesis ultrasound study in patients with early SpA. Achilles ultrasound examinations were performed at baseline, six- and twelve-month time periods and compared with clinical outcome measures collected at basal visit. Our results showed that basal erythrocyte sedimentation rate (ESR) and C-reactive protein (CRP) are higher in patients with Doppler signal in enthesis, and even that higher basal ESR, CRP and Ankylosing Spondylitis Disease Activity Score (ASDAS) predicted a higher Doppler signal (an ultrasound alteration accepted as representative of inflammation) six months later. Patients with very high disease activity assessed by ASDAS (>3.5) at baseline had significantly higher Achilles total ultrasound score verified at the same time; and ASDAS <1.3 predicted no Doppler signal at six and twelve months. This seems to represent a connection between classical biomarkers and clinical outcomes associated with SpA activity and Doppler signal, not only at the same time, but also for the following months. Remarkably, patients with inactive disease (ASDAS < 1.3) at baseline had no Doppler signal at six and twelve months. These findings reinforce the potential use of ultrasound related techniques for disease progression assessment and prognosis purposes. Intriguingly, Ankylosing Spondylitis Disease Activity Index (BASDAI) didn’t show significant differences between different cut-offs concerning ultrasound lesions or Doppler signal, while verified with ASDAS. These results seem to indicate that ASDAS reflects better than BASDAI what happens in the enthesis. The work herein discussed clearly shows the potential utility of ultrasound in enthesis assessment in SpA patients, and can be important for the development of ultrasound activity and structural damage scores for diagnosis and monitoring purposes. Therefore, local promotion of this technique constitutes a medical intervention that is worth being tested in SpA patients for diagnosis, monitoring and prognosis purposes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This case study – and accompanying teaching note – briefly describes the history of the Espírito Santo family, a banking dynasty who led one of Portugal’s leading economic and financial groups, along with its “crown jewel”, Banco Espírito Santo. It chronicles how the corporate governance issues at BES allowed the family to exploit the bank, its shareholders and its customers, so as to support its unprofitable non-financial businesses. This left the bank in a poor financial situation, which deteriorated beyond control, leaving regulators – whose actions are also analysed here – with no alternative, amidst a severe liquidity crisis, but to apply a resolution measure, pinning large losses on junior bondholders and shareholders before recapitalising the bank.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Structural connectivity models based on Diffusion Tensor Imaging (DTI) are strongly affected by the technique’s inability to resolve crossing fibres, either intra- or inter-hemispherical connections. Several models have been proposed to address this issue, including an algorithm aiming to resolve crossing fibres which is based on Diffusion Kurtosis Imaging (DKI). This technique is clinically feasible, even when multi-band acquisitions are not available, and compatible with multi-shell acquisition schemes. DKI is an extension of DTI enabling the estimation of diffusion tensor and diffusion kurtosis metrics. In this study we compare the performance of DKI and DTI in performing structural brain connectivity. Six healthy subjects were recruited, aged between 25 and 35 (three females). The MRI experiments were performed using a 3T Siemens Trio with a 32-channel head coil. The scans included a T1-weighted sequence (1mm3), and a DWI with b-values 0, 1000 and 2000 s:mm

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Many municipal activities require updated large-scale maps that include both topographic and thematic information. For this purpose, the efficient use of very high spatial resolution (VHR) satellite imagery suggests the development of approaches that enable a timely discrimination, counting and delineation of urban elements according to legal technical specifications and quality standards. Therefore, the nature of this data source and expanding range of applications calls for objective methods and quantitative metrics to assess the quality of the extracted information which go beyond traditional thematic accuracy alone. The present work concerns the development and testing of a new approach for using technical mapping standards in the quality assessment of buildings automatically extracted from VHR satellite imagery. Feature extraction software was employed to map buildings present in a pansharpened QuickBird image of Lisbon. Quality assessment was exhaustive and involved comparisons of extracted features against a reference data set, introducing cartographic constraints from scales 1:1000, 1:5000, and 1:10,000. The spatial data quality elements subject to evaluation were: thematic (attribute) accuracy, completeness, and geometric quality assessed based on planimetric deviation from the reference map. Tests were developed and metrics analyzed considering thresholds and standards for the large mapping scales most frequently used by municipalities. Results show that values for completeness varied with mapping scales and were only slightly superior for scale 1:10,000. Concerning the geometric quality, a large percentage of extracted features met the strict topographic standards of planimetric deviation for scale 1:10,000, while no buildings were compliant with the specification for scale 1:1000.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aziridines, a class of organic compounds containing a three membered heterocycle with a nitrogen atom, are extremely valuable molecules in organic and medicinal chemistry. They are frequently used as versatile precursors in the synthesis of natural products, and many biologically active molecules possess the aziridine moiety. The reactivity of aziridines has been studied, for example, in ring-opening reactions with thiols. However, not much interest seems to be given to reactions of aziridines in aqueous media, despite the numberless advantages of using water as solvent in organic chemistry. The nucleophilic ring-opening reaction of aziridines in aqueous media was here explored. Following the Kaplan aziridine synthetic methodology, in which pyridinium salts undergo a photochemical transformation to give bicyclic vinyl aziridines, new aziridines were synthetized. Their nucleophilic ring-opening reaction in water under physiological conditions was investigated and a range of sulphur, nitrogen, carbon and oxygen nucleophiles tested. Thiols, anilines and azide proved to be good nucleophiles to react with the aziridines, giving the ring-opening product in moderate to good yields. The best results were obtained with thiols, more specifically with cysteine-derived nucleophiles. Preliminary results show that these bicyclic vinyl aziridines can modify calcitonin, a peptide containing two cysteine amino acids residues, grating them the potential to be used in bioconjugation as ligands to cysteine-containing proteins, or even as enzyme inhibitors of, for example, cysteine proteases. Additionally, exploratory investigations suggest that the separation of both enantiomers of the bicyclic vinyl aziridine can be performed by taking advantage of an enzymatic methodology for the resolution of racemic secondary alcohols. Both enantiomers would be highly valuable as precursors in the synthesis of enantiomerically pure molecules, as no other method is currently reported for their separation.