20 resultados para Measurement uncertainty


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The spinning rotor gauge (SRG) is one of the most interesting vacuum gauges ever made, covering a pressure range of over seven orders of magnitude, with minimal gas interference (no pumping, ionization or heating of the measured gas), and a great stability of less than 1% drift per year. But despite its remarkable properties, apparently the SRG has not been further developed since the eighties, when it gained commercial interest. In this context, this dissertation aims at providing a starting point for a new line of investigation regarding this instrument, focused on the rotor itself. A brief study of different rotor geometries is provided, including a comparison between a cylindrical rotor and a spherical one. A cylindrical spinning rotor gauge (CSRG) is then proposed, based on the original SRG, but requiring a completely new lateral damping system. A prototype was built and tested against a non calibrated reference gauge.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nas últimas décadas, as empresas têm sido sujeitas a uma maior concorrência, ao desenvolvimento tecnológico mais acelerado e a novos desafios no que respeita à qualidade. A Metrologia deverá assim acompanhar estas tendências do mercado. O Departamento de Metrologia (DMET) do Instituto Português da Qualidade, I.P. (IPQ) tem vindo a desenvolver esforços significativos que visam a melhoria contínua das técnicas e dos processos de medição e de calibração realizados nos laboratórios. A presente dissertação de mestrado foi realizada no Laboratório de Volume e Caudal (LVC) do DMET. Os objetivos iniciais do trabalho centraram-se na caraterização metrológica de contadores de fluidos, tendo como base a medição do caudal, utilizando como método de referência o método gravimétrico. De forma a validar o sistema de medição foram realizados ensaios entre 1 mL/h a 100 mL/h, em condições de reprodutibilidade, com dois sistemas padrão distintos de acordo com o caudal a ensaiar. Em todos os ensaios efetuados foi necessário monitorizar as condições ambientais, i.e. temperatura, pressão atmosférica, humidade relativa e a temperatura do líquido padrão, para a aplicação das correções necessárias. Outro feito importante foi a caraterização das fontes de incerteza, que permitiram caraterizar o resultado das medições. A metodologia utilizada para a avaliação e para a estimativa da incerteza de medição encontra-se descrita no Guide to the Expression of Uncertainty in Measurement (GUM). Neste projeto foram contempladas fontes de incerteza como as associadas à evaporação, à impulsão do tubo, à resolução da balança, entre outras. Com os resultados obtidos foi possível elaborar um procedimento técnico para a Calibração de Caudalímetros de Líquidos. Os resultados obtidos permitiram garantir a rastreabilidade das medições de caudal de líquidos ao SI, essencial para a calibração de equipamentos no Laboratório Nacional de Metrologia (LNM) do IPQ, nomeadamente para micro caudalímetros no intervalo de medição entre 0,12 mL/h e 600 mL/h.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effects of PMSs on the people’s behaviour represent a high degree of relevance in the context of an organization performance and success. Thus, motivational and behavioural consequences of performance measurements are far from being totally understood (Franco-Santos et al., 2012). This work project (WP) purposes going further regarding the consequences/effects on people’s behaviour of using PMSs in organizations. The researcher conducted 11 interviews to managers during a nine-month internship as a controller in a Portuguese multi-national company. The evidence from this WP suggests that the way how managers understand a PMS determines a lot the way how they behave. Data also supports that PMSs influences in several ways motivation, perceptions, participation and job-related stress of managers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Relationships between accuracy and speed of decision-making, or speed-accuracy tradeoffs (SAT), have been extensively studied. However, the range of SAT observed varies widely across studies for reasons that are unclear. Several explanations have been proposed, including motivation or incentive for speed vs. accuracy, species and modality but none of these hypotheses has been directly tested. An alternative explanation is that the different degrees of SAT are related to the nature of the task being performed. Here, we addressed this problem by comparing SAT in two odor-guided decision tasks that were identical except for the nature of the task uncertainty: an odor mixture categorization task, where the distinguishing information is reduced by making the stimuli more similar to each other; and an odor identification task in which the information is reduced by lowering the intensity over a range of three log steps. (...)