21 resultados para Lane use control signals.


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia do Ambiente Perfil de Engenharia de Sistemas Ambientais

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Digital Microfluidics (DMF) is a second generation technique, derived from the conventional microfluidics that instead of using continuous liquid fluxes, it uses only individual droplets driven by external electric signals. In this thesis a new DMF control/sensing system for visualization, droplet control (movement, dispensing, merging and splitting) and real time impedance measurement have been developed. The software for the proposed system was implemented in MATLAB with a graphical user interface. An Arduino was used as control board and dedicated circuits for voltage switching and contacts were designed and implemented in printed circuit boards. A high resolution camera was integrated for visualization. In our new approach, the DMF chips are driven by a dual-tone signal where the sum of two independent ac signals (one for droplet operations and the other for impedance sensing) is applied to the electrodes, and afterwards independently evaluated by a lock-in amplifier. With this new approach we were able to choose the appropriated amplitudes and frequencies for the different proposes (actuation and sensing). The measurements made were used to evaluate the real time droplet impedance enabling the knowledge of its position and velocity. This new approach opens new possibilities for impedance sensing and feedback control in DMF devices.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

RESUMO: Introdução: Uma meta-análise recente demonstrou que uso adjuvante de ácido zoledrónico (AZ) em mulheres pós-menopáusicas com cancro da mama precoce (CM) conduz a redução do risco de morte por CM em 17%. Investigámos o efeito do estado hormonal (pré [PrM] vs pós-menopausa tardia [PoM]) na remodelação óssea e controlo de doença em mulheres com CM e metástases ósseas (MO) tratadas com AZ e quimioterapia (QT). Métodos: Neste estudo de coorte retrospetivo, colhemos variáveis clinico-patológicas e quantificámos o telopéptido N-terminal (NTX) urinário e marcadores tumorais (MT) séricos em mulheres com CM e MO tratadas com QT e AZ. As doentes foram divididas em PrM (<45 anos) e PoM (>60 anos). Endpoints do estudo: variação do NTX, CA15.3 e CEA nos meses 3, 6 e 9, tempo até falência de QT de primeira-linha e sobrevivência. Quando apropriado foram usados os testes de Wilcoxon rank-sum, modelo de efeitos lineares mistos, teste log-rank e modelo de Cox. Resultados: Quarenta doentes foram elegíveis para análise (8 PrM e 32 PoM). Depois da introdução de AZ e QT, os níveis de NTX e MT caíram no coorte global. O perfil de resposta não diferiu entre grupos no mês 3 ou em tempos posteriores (valor-p para interação tempo-estado hormonal no mês 3=0.957). Ademais, o perfil de resposta dos MT também não diferiu entre grupos. O tempo mediano até falência de primeira-linha de QT em PrM e PoM foi de 15.2 e 17.4 meses, respetivamente. Não foi identificada diferença significativa entre grupos, quer em análise univariada quer após controlo para envolvimento visceral (p=0.399 e 0.469, respetivamente). Igualmente, não houve diferenças em termos de sobrevivência. Conclusões: Neste coorte, não foram identificadas diferenças no controlo de NTX ou MT em função do estado menopausico. Igualmente, não foi identificada diferença no tempo até falência de primeira-linha de CT ou sobrevivência.----------- ABSTRACT: Background: A recent meta-analysis showed that the adjuvant use of zoledronic acid (ZA) in postmenopausal women with early breast cancer (BC) leads to a reduction in the risk of breast cancer death by 17%. We investigated the effect of the hormonal status (pre [PrM] vs late post menopause [PoM]) on bone turnover and disease control among women with BC and boné metastases (BM) treated with ZA and chemotherapy (CT). Methods: In this retrospective cohort study, we collected clinicopathologic variables, urinary Nterminal telopeptide (NTX) and serum tumor marker levels from women with BC and BM treated with CT and ZA. Patients were divided in PrM (<45 years) and PoM (>60 years). Study endpoints were NTX, CA15.3 and CEA variation at 3, 6 and 9 months, and time to first-line CT failure and survival. We performed multilevel mixed-effects linear regression models to assess the variation of repeated measures and cox regression models for time to event outcomes. Results: Forty patients were eligible for analysis (8 PrM and 32 PoM). After introduction of ZA and CT, NTX and tumor markers declined in the overall cohort. Response profile was similar between menopausal groups at month 3 and at later time points (p-value for time-hormonal status interaction at month 3=0.957). Furthermore, tumor markers response profile was also equal between groups. Median time to first-line CT failure in PrM and PoM women was 15.2 and 17.4 months, respectively. No significant difference between groups was found, either using a univariate analysis or after controlling for visceral disease involvement (p=0.399 and 0.469, respectively). Likewise, no differences in survival were found. Conclusions: In this cohort, no differences were found in terms of NTX or tumor markers control according to menopausal status. Similarly, no difference in time to first-line CT failure or survival was found.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In-Band Full-DupleX (IB-FDX) is defined as the ability for nodes to transmit and receive signals simultaneously on the same channel. Conventional digital wireless networks do not implement it, since a node’s own transmission signal causes interference to the signal it is trying to receive. However, recent studies attempt to overcome this obstacle, since it can potentially double the spectral efficiency of current wireless networks. Different mechanisms exist today that are able to reduce a significant part of the Self- Interference (SI), although specially tuned Medium Access Control (MAC) protocols are required to optimize its use. One of IB-FDX’s biggest problems is that the nodes’ interference range is extended, meaning the unusable space for other transmissions and receptions is broader. This dissertation proposes using MultiPacket Reception (MPR) to address this issue and adapts an already existing Single-Carrier with Frequency-Domain Equalization (SC-FDE) receiver to IB-FDX. The performance analysis suggests that MPR and IB-FDX have a strong synergy and are able to achieve higher data rates, when used together. Using analytical models, the optimal transmission patterns and transmission power were identified, which maximize the channel capacity with the minimal energy consumption. This was used to define a new MAC protocol, named Full-duplex Multipacket reception Medium Access Control (FM-MAC). FM-MAC was designed for a single-hop cellular infrastructure, where the Access Point (AP) and the terminals implement both IB-FDX and MPR. It divides the coverage range of the AP into a closer Full-DupleX (FDX) zone and a farther Half-DupleX (HDX) zone and adds a tunable fairness mechanism to avoid terminal starvation. Simulation results show that this protocol provides efficient support for both HDX and FDX terminals, maximizing its capacity when more FDX terminals are used.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The capacity to use geologic materials (soil and rock) that are available in the surrounding environment is inherent to the human civilization and has contributed to the evolution of societies throughout the course of history. The use of these materials in the construction of structures such as houses, roads, railways or dams, stirred the improvement of socioeconomic and environmental conditions. Several reports of structural problems on embankments can be found throughout history. A considerable number of those registers can be linked to inadequate compaction, demonstrating the importance of guaranteeing a suitable quality of soil compaction. Various methodologies and specifications of compaction quality control on site of earthworks, based on the fill moisture content and dry unit weight, were developed during the 20th century. Two widely known methodologies are the conventional and nuclear techniques. The conventional methods are based on the use of the field sand cone test (or similar) and sampling of material for laboratory-based testing to evaluate the fill dry unit weight and water content. The nuclear techniques measure both parameters in the field using a nuclear density gauge. A topic under discussion in the geotechnical community, namely in Portugal, is the comparison between the accuracy of the nuclear gauge and sand cone test results for assessing the compaction and density ratio of earth fills, particularly for dams. The main purpose of this dissertation is to compare both of them. The data used were acquired during the compaction quality control operations at the Coutada/Tamujais dam trial embankment and core construction. This is a 25 m high earth dam located in Vila Velha de Rodão, Portugal. To analyse the spatial distribution of the compaction parameters (water content and compaction ratio), a 3D model was also developed. The main results achieved are discussed and finally some considerations are put forward on the suitability of both techniques to ensure fill compaction quality and on additional research to complement the conclusions obtained.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The way in which electricity networks operate is going through a period of significant change. Renewable generation technologies are having a growing presence and increasing penetrations of generation that are being connected at distribution level. Unfortunately, a renewable energy source is most of the time intermittent and needs to be forecasted. Current trends in Smart grids foresee the accommodation of a variety of distributed generation sources including intermittent renewable sources. It is also expected that smart grids will include demand management resources, widespread communications and control technologies required to use demand response are needed to help the maintenance in supply-demand balance in electricity systems. Consequently, smart household appliances with controllable loads will be likely a common presence in our homes. Thus, new control techniques are requested to manage the loads and achieve all the potential energy present in intermittent energy sources. This thesis is focused on the development of a demand side management control method in a distributed network, aiming the creation of greater flexibility in demand and better ease the integration of renewable technologies. In particular, this work presents a novel multi-agent model-based predictive control method to manage distributed energy systems from the demand side, in presence of limited energy sources with fluctuating output and with energy storage in house-hold or car batteries. Specifically, here is presented a solution for thermal comfort which manages a limited shared energy resource via a demand side management perspective, using an integrated approach which also involves a power price auction and an appliance loads allocation scheme. The control is applied individually to a set of Thermal Control Areas, demand units, where the objective is to minimize the energy usage and not exceed the limited and shared energy resource, while simultaneously indoor temperatures are maintained within a comfort frame. Thermal Control Areas are overall thermodynamically connected in the distributed environment and also coupled by energy related constraints. The energy split is performed based on a fixed sequential order established from a previous completed auction wherein the bids are made by each Thermal Control Area, acting as demand side management agents, based on the daily energy price. The developed solutions are explained with algorithms and are applied to different scenarios, being the results explanatory of the benefits of the proposed approaches.