21 resultados para K-Fold Accuracy
Resumo:
Cryocoolers have been progressively replacing the use of the stored cryogens in cryogenic chains used for detector cooling, thanks to their higher and higher reliability. However, the mechanical vibrations, the electromagnetic interferences and the temperature fluctuations inherent to their functioning could reduce the sensor’s sensitivity. In order to minimize this problem, compact thermal energy storage units (ESU) are studied, devices able to store thermal energy without significant temperature increase. These devices can be used as a temporary cold source making it possible to turn the cryocooler OFF providing a proper environment for the sensor. A heat switch is responsible for the thermal decoupling of the ESU from the cryocooler’s temperature that increases when turned OFF. In this work, several prototypes working around 40 K were designed, built and characterized. They consist in a low temperature cell that contains the liquid neon connected to an expansion volume at room temperature for gas storage during the liquid evaporation phase. To turn this system insensitive to the gravity direction, the liquid is retained in the low temperature cell by capillary effect in a porous material. Thanks to pressure regulation of the liquid neon bath, 900 J were stored at 40K. The higher latent heat of the liquid and the inexistence of triple point transitions at 40 K turn the pressure control during the evaporation a versatile and compact alternative to an ESU working at the triple point transitions. A quite compact second prototype ESU directly connected to the cryocooler cold finger was tested as a temperature stabilizer. This device was able to stabilize the cryocooler temperature ((≈ 40K ±1 K) despite sudden heat bursts corresponding to twice the cooling power of the cryocooler. This thesis describes the construction of these devices as well as the tests performed. It is also shown that the thermal model developed to predict the thermal behaviour of these devices, implemented as a software,describes quite well the experimental results. Solutions to improve these devices are also proposed.
Resumo:
Cryocoolers have been progressively replacing the use of the stored cryogens in cryogenic chains used for detector cooling, thanks to their higher and higher reliability. However, the mechanical vibrations, the electromagnetic interferences and the temperature fluctuations inherent to their functioning could reduce the sensor’s sensitivity. In order to minimize this problem, compact thermal energy storage units (ESU) are studied, devices able to store thermal energy without significant temperature increase. These devices can be used as a temporary cold source making it possible to turn the cryocooler OFF providing a proper environment for the sensor. A heat switch is responsible for the thermal decoupling of the ESU from the cryocooler’s temperature that increases when turned OFF. In this work, several prototypes working around 40 K were designed, built and characterized. They consist in a low temperature cell that contains the liquid neon connected to an expansion volume at room temperature for gas storage during the liquid evaporation phase. To turn this system insensitive to the gravity direction, the liquid is retained in the low temperature cell by capillary effect in a porous material. Thanks to pressure regulation of the liquid neon bath, 900 J were stored at 40K. The higher latent heat of the liquid and the inexistence of triple point transitions at 40 K turn the pressure control during the evaporation a versatile and compact alternative to an ESU working at the triple point transitions. A quite compact second prototype ESU directly connected to the cryocooler cold finger was tested as a temperature stabilizer. This device was able to stabilize the cryocooler temperature ((≈ 40K ±1 K) despite sudden heat bursts corresponding to twice the cooling power of the cryocooler. This thesis describes the construction of these devices as well as the tests performed. It is also shown that the thermal model developed to predict the thermal behaviour of these devices,implemented as a software, describes quite well the experimental results. Solutions to improve these devices are also proposed.
Resumo:
NSBE - UNL
Resumo:
This project characterizes the accuracy of the escrowed dividend model on the value of European options on a stock paying discrete dividend. A description of the escrowed dividend model is provided, and a comparison between this model and the benchmark model is realized. It is concluded that options on stocks with either low volatility, low dividend yield, low ex-dividend to maturity ratio or that are deep in or out of the money are reasonably priced with the escrowed dividend model.
Resumo:
Several studies have demonstrated that although the structure of the adult and larval zebrafish caudal fin is different, there are similarities at the cellular and molecular level that turn larval zebrafish fin fold a useful model to study the basic principles of regeneration. In this process, while the essential role for Hedgehog (Hh) signaling is well established in the adult zebrafish caudal fin system, its involvement in juvenile tissue regeneration is still unknown. The aim of this Master thesis was therefore to evaluate the contribution of the Hh signaling pathway to the larval zebrafish fin fold regeneration process. Accordingly, we analyzed the expression of several Hh signaling components through in situ hybridization. Here, we showed that several of these genes are effectively expressed in the larval regenerating fin tissue, suggesting a role for Hh signaling also during larval regeneration. However, divergence in the regulation of few Hh signaling components appears to exist between the adult and larval zebrafish fin regeneration processes. Nevertheless, similarly to adult caudal fin regeneration, when Hh signaling was blocked, by using cyclopamine, the larval fin fold regenerative outgrowth is severely impaired. Since larval zebrafish fin fold is ciliated, and primary cilia are closely related to Hh signaling regulation in vertebrate systems, we further addressed the role of primary cilia during larval fin fold regeneration process. To this end, we used the zebrafish iguana mutant, in which primary cilia are not formed, to study the modulation of Hh signaling expression during larval fin fold regeneration in the absence of primary cilia. Here, we found that several genes were expressed with a delay, coincident with the delay in the mutant fin fold regeneration observed in previous work. We show that Hh signaling in the fin fold is crucial to promote cell proliferation. When Hh signaling is blocked using cyclopamine there is a strong blockage of cell proliferation and regeneration is also blocked. Surprisingly, in iguana mutants where Hh signaling is impaired but not totally blocked, cell proliferation is not detected but regeneration still occurs. This raises the question about the requirement of cell proliferation in larvae fin fold regeneration. By blocking the cell cycle using aphidicolin we demonstrate that cell proliferation is not necessary for zebrafish larvae fin fold regeneration.
Resumo:
This thesis examines the effects of macroeconomic factors on inflation level and volatility in the Euro Area to improve the accuracy of inflation forecasts with econometric modelling. Inflation aggregates for the EU as well as inflation levels of selected countries are analysed, and the difference between these inflation estimates and forecasts are documented. The research proposes alternative models depending on the focus and the scope of inflation forecasts. I find that models with a Generalized AutoRegressive Conditional Heteroskedasticity (GARCH) in mean process have better explanatory power for inflation variance compared to the regular GARCH models. The significant coefficients are different in EU countries in comparison to the aggregate EU-wide forecast of inflation. The presence of more pronounced GARCH components in certain countries with more stressed economies indicates that inflation volatility in these countries are likely to occur as a result of the stressed economy. In addition, other economies in the Euro Area are found to exhibit a relatively stable variance of inflation over time. Therefore, when analysing EU inflation one have to take into consideration the large differences on country level and focus on those one by one.