3 resultados para Land use and cover change

em Instituto Polit


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Considering that ionizing radiation effects are cumulative and the gonads are particularly sensitive to these effects, and also the clinical importance of pelvic radiographs in children, the excess of radiation exposure to the gonads must be avoided. The purpose of this study is to demonstrate the relevance of the correct use of gonad protection shields and to evaluate their use on the hip radiographs performed in a reference clinical institution, through the retrospective analysis of pelvic radiographic images performed in children. According the image quality assessment, 20 (40%) patients were unprotected and gonads shields were incorrectly placed in 24 (80%) patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Seven pyrethroids (bifenthrin, fenpropathrin, k-cyhalothrin, permethrin, a-cypermethrin, fenvalerate, and deltamethrin) were extracted from water using C18 solid-phase extraction disks, followed by gas chromatography with an electron capture detector (GC-ECD) analysis. The limits of detection in water samples ranged from 0.5 ng L-1 (fenpropathrin) to 110 ng L- 1 (permethrin), applying the calibration graph. The effects of different numbers of (re)utilizations of the same disks (up to four times with several concentrations) on the recoveries of the pyrethroids were considered. The recoveries were all between 70 and 120% after four utilizations of the same disk. There was no difference between these recoveries at a confidence level of 95%.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The ventilation efficiency concept is an attempt to quantify a parameter that can easily distinguish the different options for air diffusion in the building spaces. Thirteen strategies of air diffusion were measured in a test chamber through the application of the tracer gas method, with the objective to validate the calculation by Computational fluid dynamics (CFD). Were compared the Air Change Efficiency (ACE) and the Contaminant Removal Effectiveness (CRE), the two indicators most internationally accepted. The main results from this work shows that the values of the numerical simulations are in good agreement with experimental measurements and also, that the solutions to be adopted for maximizing the ventilation efficiency should be the schemes that operate with low speeds of supply air and small differences between supply air temperature and the room temperature.