18 resultados para wwPDB validation

em Instituto Politécnico do Porto, Portugal


Relevância:

20.00% 20.00%

Publicador:

Resumo:

An accurate and sensitive method for determination of 18 polycyclic aromatic hydrocarbons (PAHs) (16 PAHs considered by USEPA as priority pollutants, dibenzo[a,l]pyrene and benzo[j]fluoranthene) in fish samples was validated. Analysis was performed by microwave-assisted extraction and liquid chromatography with photodiode array and fluorescence detection. Response surface methodology was used to find the optimal extraction parameters. Validation of the overall methodology was performed by spiking assays at four levels and using SRM 2977. Quantification limits ranging from 0.15–27.16 ng/g wet weight were obtained. The established method was applied in edible tissues of three commonly consumed and commercially valuable fish species (sardine, chub mackerel and horse mackerel) originated from Atlantic Ocean. Variable levels of naphthalene (1.03–2.95 ng/g wet weight), fluorene (0.34–1.09 ng/g wet weight) and phenanthrene (0.34–3.54 ng/g wet weight) were detected in the analysed samples. None of the samples contained detectable amounts of benzo[a]pyrene, the marker used for evaluating the occurrence and carcinogenic effects of PAHs in food.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Scientific evidence has shown an association between organochlorine compounds (OCC) exposure and human health hazards. Concerning this, OCC detection in human adipose samples has to be considered a public health priority. This study evaluated the efficacy of various solid-phase extraction (SPE) and cleanup methods for OCC determination in human adipose tissue. Octadecylsilyl endcapped (C18-E), benzenesulfonic acid modified silica cation exchanger (SA), poly (styrene-divinylbenzene (EN) and EN/RP18 SPE sorbents were evaluated. The relative sample cleanup provided by these SPE columns was evaluated using gas chromatography with electron capture detection (GC–ECD). The C18-E columns with strong homogenization were found to provide the most effective cleanup, removing the greatest amount of interfering substance, and simultaneously ensuring good analyte recoveries higher than 70%. Recoveries>70% with standard deviations (SD)<15% were obtained for all compounds under the selected conditions. Method detection limits were in the 0.003–0.009 mg/kg range. The positive samples were confirmed by gas chromatography coupled with tandem mass spectrometry (GC-MS/MS). The highest percentage found of the OCC in real samples corresponded to HCB, o,p′-DDT and methoxychlor, which were detected in 80 and 95% of samples analyzed respectively. Copyright © 2012 John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Environmental pollution continues to be an emerging study field, as there are thousands of anthropogenic compounds mixed in the environment whose possible mechanisms of toxicity and physiological outcomes are of great concern. Developing methods to access and prioritize the screening of these compounds at trace levels in order to support regulatory efforts is, therefore, very important. A methodology based on solid phase extraction followed by derivatization and gas chromatography-mass spectrometry analysis was developed for the assessment of four endocrine disrupting compounds (EDCs) in water matrices: bisphenol A, estrone, 17b-estradiol and 17a-ethinylestradiol. The study was performed, simultaneously, by two different laboratories in order to evaluate the robustness of the method and to increase the quality control over its application in routine analysis. Validation was done according to the International Conference on Harmonisation recommendations and other international guidelines with specifications for the GC-MS methodology. Matrix-induced chromatographic response enhancement was avoided by using matrix-standard calibration solutions and heteroscedasticity has been overtaken by a weighted least squares linear regression model application. Consistent evaluation of key analytical parameters such as extraction efficiency, sensitivity, specificity, linearity, limits of detection and quantification, precision, accuracy and robustness was done in accordance with standards established for acceptance. Finally, the application of the optimized method in the assessment of the selected analytes in environmental samples suggested that it is an expedite methodology for routine analysis of EDC residues in water matrices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new procedure for determining eleven organochlorine pesticides in soils using microwave-assisted extraction (MAE) and headspace solid phase microextraction (HS-SPME) is described. The studied pesticides consisted of mirex, α- and γ-chlordane, p,p’-DDT, heptachlor, heptachlor epoxide isomer A, γ-hexachlorocyclohexane, dieldrin, endrin, aldrine and hexachlorobenzene. The HS-SPME was optimized for the most important parameters such as extraction time, sample volume and temperature. The present analytical procedure requires a reduced volume of organic solvents and avoids the need for extract clean-up steps. For optimized conditions the limits of detection for the method ranged from 0.02 to 3.6 ng/g, intermediate precision ranged from 14 to 36% (as CV%), and the recovery from 8 up to 51%. The proposed methodology can be used in the rapid screening of soil for the presence of the selected pesticides, and was applied to landfill soil samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Amulti-residue methodology based on a solid phase extraction followed by gas chromatography–tandem mass spectrometry was developed for trace analysis of 32 compounds in water matrices, including estrogens and several pesticides from different chemical families, some of them with endocrine disrupting properties. Matrix standard calibration solutions were prepared by adding known amounts of the analytes to a residue-free sample to compensate matrix-induced chromatographic response enhancement observed for certain pesticides. Validation was done mainly according to the International Conference on Harmonisation recommendations, as well as some European and American validation guidelines with specifications for pesticides analysis and/or GC–MS methodology. As the assumption of homoscedasticity was not met for analytical data, weighted least squares linear regression procedure was applied as a simple and effective way to counteract the greater influence of the greater concentrations on the fitted regression line, improving accuracy at the lower end of the calibration curve. The method was considered validated for 31 compounds after consistent evaluation of the key analytical parameters: specificity, linearity, limit of detection and quantification, range, precision, accuracy, extraction efficiency, stability and robustness.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Food lipid major components are usually analyzed by individual methodologies using diverse extractive procedures for each class. A simple and fast extractive procedure was devised for the sequential analysis of vitamin E, cholesterol, fatty acids, and total fat estimation in seafood, reducing analyses time and organic solvent consumption. Several liquid/liquid-based extractive methodologies using chlorinated and non-chlorinated organic solvents were tested. The extract obtained is used for vitamin E quantification (normal-phase HPLC with fluorescence detection), total cholesterol (normal-phase HPLC with UV detection), fatty acid profile, and total fat estimation (GC-FID), all accomplished in <40 min. The final methodology presents an adequate linearity range and sensitivity for tocopherol and cholesterol, with intra- and inter-day precisions (RSD) from 3 to 11 % for all the components. The developed methodology was applied to diverse seafood samples with positive outcomes, making it a very attractive technique for routine analyses in standard equipped laboratories in the food quality control field.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

WiDom is a wireless prioritized medium access control protocol which offers a very large number of priority levels. Hence, it brings the potential to employ non-preemptive static-priority scheduling and schedulability analysis for a wireless channel assuming that the overhead of WiDom is modeled properly. One schedulability analysis for WiDom has already been proposed but recent research has created a new version of WiDom (we call it: Slotted WiDom) with lower overhead and for this version of WiDom no schedulability analysis exists. In this paper we propose a new schedulability analysis for slotted WiDom and extend it to work also for message streams with release jitter. We have performed experiments with an implementation of slotted WiDom on a real-world platform (MicaZ). We find that for each message stream, the maximum observed response time never exceeds the calculated response time and hence this corroborates our belief that our new scheduling theory is applicable in practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The IEEE 802.15.4 is the most widespread used protocol for Wireless Sensor Networks (WSNs) and it is being used as a baseline for several higher layer protocols such as ZigBee, 6LoWPAN or WirelessHART. Its MAC (Medium Access Control) supports both contention-free (CFP, based on the reservation of guaranteed time-slots GTS) and contention based (CAP, ruled by CSMA/CA) access, when operating in beacon-enabled mode. Thus, it enables the differentiation between real-time and best-effort traffic. However, some WSN applications and higher layer protocols may strongly benefit from the possibility of supporting more traffic classes. This happens, for instance, for dense WSNs used in time-sensitive industrial applications. In this context, we propose to differentiate traffic classes within the CAP, enabling lower transmission delays and higher success probability to timecritical messages, such as for event detection, GTS reservation and network management. Building upon a previously proposed methodology (TRADIF), in this paper we outline its implementation and experimental validation over a real-time operating system. Importantly, TRADIF is fully backward compatible with the IEEE 802.15.4 standard, enabling to create different traffic classes just by tuning some MAC parameters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Polyolefins are especially difficult to bond due to their non-polar, non-porous and chemically inert surfaces. Acrylic adhesives used in industry are particularly suited to bond these materials, including many grades of polypropylene (PP) and polyethylene (PE), without special surface preparation. In this work, the tensile strength of single-lap PE and mixed joints bonded with an acrylic adhesive was investigated. The mixed joints included PE with aluminium (AL) or carbon fibre reinforced plastic (CFRP) substrates. The PE substrates were only cleaned with isopropanol, which assured cohesive failures. For the PE CFRP joints, three different surfaces preparations were employed for the CFRP substrates: cleaning with acetone, abrasion with 100 grit sand paper and peel-ply finishing. In the PE AL joints, the AL bonding surfaces were prepared by the following methods: cleaning with acetone, abrasion with 180 and 320 grit sand papers, grit blasting and chemical etching with chromic acid. After abrasion of the CFRP and AL substrates, the surfaces were always cleaned with acetone. The tensile strengths were compared with numerical results from ABAQUS® and a mixed mode (I+II) cohesive damage model. A good agreement was found between the experimental and numerical results, except for the PE AL joints, since the AL surface treatments were not found to be effective.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Prototype validation is a major concern in modern electronic product design and development. Simulation, structural test, functional and timing debug are all forming parts of the validation process, although very often addressed as dissociated tasks. In this paper we describe an integrated approach to board-level prototype validation, based on a set of mandatory/optional BST instructions and a built-in controller for debug and test, that addresses the late mentioned tasks as inherent parts of a whole process

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Artigo científico disponível actualmente em Early View (Online Version of Record published before inclusion in an issue)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: This work aims at further developing and testing the psychometric properties of the Cultural Intelligence Scale (Ang & Van Dyne, 2006) in an Erasmus Mundus Students and Alumni Population, including reliability. Design Methodology: The study included 626 participants from 109 different countries that emcompasses 6 continents. Exploratory and Confirmatory Factor Analysis procedures were carried out in order to test the scale in a multicultural scale of Erasmus Mundus Students. Reliability was assessed using Cronbach Alpha. Results: The scale presents excellent psychometric properties with alpha values that range from .84 to .90. Exploratory and Confirmatory Factor Analyses demonstrated that the original model of the scale presents an exceptionally good fit. Limitations: The present study was conducted using a convenience sample and online questionnaires that limit its conclusions when we consider the globality of the Erasmus Mundus Students. Research/Practical Implications: This study presents evidence that Ang and Van Dyne’s scale is an adequate measure instrument to assess intercultural intelligence in a multicultural setting of students and alumni. Originality/Value: Multicultural samples and studies are becoming more and more present and relevant; the study of intercultural competences and habilities is becoming increasingly important, and in this task, solid psychometric instruments are of paramount importance. This study presents evidence that Ang and Van Dyne’s (2006) scale is a fairly recent and parsimonious instrument with excellent psychometric properties properties.