23 resultados para pyrophosphate fructose 6 phosphate 1 phosphotransferase

em Instituto Politécnico do Porto, Portugal


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The electrooxidative behavior of citalopram (CTL) in aqueous media was studied by cyclic voltammetry (CV) and square-wave voltammetry (SWV) at a glassy-carbon electrode. The electrochemical behaviour of CTL involves two electrons and two protons in the irreversible and diffusion controlled oxidation of the tertiary amine group. The maximum analytical signal was obtained in a phosphate buffer (pH ¼ 8.2). For analytical purposes, an SWV method and a flow-injection analysis (FIA) system with amperometric detection were developed. The optimised SWV method showed a linear range between 1.10 10 5–1.20 10 4 molL 1, with a limit of detection (LOD) of 9.5 10 6 molL 1. Using the FIA method, a linear range between 2.00 10 6–9.00 10 5 molL 1 and an LODof 1.9 10 6 molL 1 were obtained. The validation of both methods revealed good performance characteristics confirming applicability for the quantification of CTL in several pharmaceutical products.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An electrochemical sensor has been developed for the determination of the herbicide bentazone, based on a GC electrode modified by a combination of multiwalled carbon nanotubes (MWCNT) with b-cyclodextrin (b-CD) incorporated in a polyaniline film. The results indicate that the b-CD/MWCNT modified GC electrode exhibits efficient electrocatalytic oxidation of bentazone with high sensitivity and stability. A cyclic voltammetric method to determine bentazone in phosphate buffer solution at pH 6.0, was developed, without any previous extraction, clean-up, or derivatization steps, in the range of 10–80 mmolL 1, with a detection limit of 1.6 mmolL 1 in water. The results were compared with those obtained by an established HPLC technique. No statistically significant differences being found between both methods.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work proposes different kind of solid-contact graphite-based electrodes for the selective determination of sulphonamides (SPHs) in pharmaceuticals, biological fluids and aquaculture waters. Sulfadiazine (SDZ) and sulfamethoxazole (SMX) were selected for this purpose for being the most representative compounds of this group. The template molecules were imprinted in sol–gel (ISG) and the resulting material was used as detecting element. This was made by employing it as either a sensing layer or an ionophore of PVC-based membranes and subsequent potentiometric transduction, a strategy never reported before. The corresponding non-imprinted sol–gel (NISG) membranes were used as blank. The effect of plasticizer and kind/charge of ionic lipophilic additive was also studied. The best performance in terms of slope, linearity ranges and signal reproducibility and repeatability was achieved by PVC membranes including a high dielectric constant plasticizer and 15 mg of ISG particles. The corresponding average slope was −51.4 and −52.4 mV/decade, linear responses were 9.0 × 10−6 and 1.7 × 10−5 M, and limits of detection were 0.74 and 1.3 μg/mL for SDZ and for SMX, respectively. Good selectivity with log Kpot < −0.3 was observed for carbonate, chloride, fluoride, hydrogenocarbonate, nitrate, nitrite, phosphate, cyanide, sulfate, borate, persulphate, citrate, tartrate, salicylate, tetracycline, ciprofloxacin, sulphamerazine, sulphatiazole, dopamine, glucose, galactose, cysteine and creatinine. The best sensors were successfully applied to the analysis of real samples with relative errors ranging from −6.8 to + 3.7%.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

As sequelas fisiopatológicas do stress oxidativo são difíceis de quantificar. Apesar dos obstáculos, a relevância médica do stress oxidativo tem vindo a ser cada vez mais reconhecida, sendo hoje em dia encarado como um componente chave de virtualmente todas as doenças. A disfunção erétil (DE) surge neste contexto como uma espécie de barómetro da função endotelial e do dano oxidativo. A quantificação de biomarcadores de stress oxidativo poderá apresentar um enorme impacto na avaliação de pacientes com DE. O rácio glutationa reduzida/oxidada (GSH/GSSG) e a nitrotirosina (3-NT) têm vindo a demonstrar relevância clínica. A consideração de polimorfismos genéticos constitui ainda uma abordagem promissora na avaliação destas relações no futuro. Um método altamente sensível de cromatografia líquida de alta performance (HPLC) foi desenvolvido para a determinação de 3-NT em plasma humano. As concentrações de 3-NT medidos em indivíduos com DE foram 6,6±2,1μM (média±S.D., n = 46). A medição da concentração plasmática de 3-NT poderá revelar-se útil como marcador de dano oxidativo dependente do óxido nítrico (NO). O nível de stress oxidativo pode também ser quantificado através da medição do decréscimo do rácio GSH/GSSG, que tem mostrado alterações numa miríade de patologias, como a DE e a diabetes mellitus. O método proposto para a quantificação do rácio GSH/GSSG em HPLC apresenta a vantagem de avaliação concomitante dos dois parâmetros em apenas uma corrida. O valor do rácio GSH/GSSG obtido a partir de sangue de indivíduos com DE foi 11,9±9,8 (média±S.D., n = 49). Os resultados estatísticos revelaram diferenças significativas (p<0,001) entre ambos a concentração plasmática de 3-NT e o rácio GSH/GSSG de sangue de indivíduos com DE e as respetivas medições em indivíduos saudáveis. Observaram-se ainda diferenças estatisticamente significativas (p≈0,027) entre o rácio GSH/GSSG do sangue de pacientes apenas com diagnóstico de DE e a medição respetiva em indivíduos com DE e comorbilidades cardiovasculares. Estes resultados enfatizam o papel do dano oxidativo na biopatologia da DE, elucidado com o auxílio destas duas metodologias, que poderão ter um amplo campo de aplicação no futuro, dado que se mostraram simples, não dispendiosas e rápidas, podendo eventualmente adequar-se a estudos de rastreio em larga escala.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A constante e sistemática subida de preço dos combustíveis fósseis e as contínuas preocupações com o meio ambiente determinaram a procura de soluções ambientalmente sustentáveis. O biodiesel surge, então, como uma alternativa para essa problemática, bem como uma solução para resíduos líquidos e gordurosos produzidos pelo ser humano. A produção de biodiesel tem sido alvo de extensa atenção nos últimos anos, pois trata-se de um combustível biodegradável e não poluente. A produção de biodiesel pelo processo de transesterificação usando álcoois de cadeia curta e catalisadores químicos, nomeadamente alcalinos, tem sido aceite industrialmente devido à sua elevada conversão. Recentemente, a transesterificação enzimática tem ganho adeptos. No entanto, o custo da enzima permanece uma barreira para a sua aplicação em grande escala. O presente trabalho visa a produção de biodiesel por transesterificação enzimática a partir de óleo residual de origem vegetal. O álcool usado foi o etanol, em substituição do metanol usado convencionalmente na catálise homogénea, pois a atividade da enzima é inibida pela presença deste último. As maiores dificuldades apresentadas na etanólise residem na separação das fases (Glicerol e Biodiesel) após a reação bem como na menor velocidade de reação. Para ajudar a colmatar esta desvantagem foi estudada a influência de dois cosolventes: o hexano e o hexanol, na proporção de 20% (v/v). Após a escolha do co-solvente que permite obter melhor rendimento (o hexano), foi elaborado um planeamento fatorial no qual se estudou a influência de três variáveis na produção de biodiesel por catálise enzimática com etanol e co-solventes: a razão molar óleo/álcool (1:8, 1:6 e 1:4), a quantidade de co-solvente adicionado (30, 20 e 10%, v/v) e o tempo de reação (48, 36 e 24h). A avaliação do processo foi inicialmente seguida pelo rendimento da reação, a fim de identificar as melhores condições, sendo substituída posteriormente pela quantificação do teor de ésteres por cromatografia em fase gasosa. O biodiesel com teor de ésteres mais elevado foi produzido nas condições correspondentes a uma razão molar óleo:álcool de 1:4, com 5g de Lipozyme TL IM como catalisador, 10% co-solvente (hexano, v/v), à temperatura de 35 ºC durante 24h. O rendimento do biodiesel produzido sob estas condições foi de 73,3%, traduzido em 64,7% de teor de ésteres etílicos. Contudo o rendimento mais elevado que se obteve foi de 99,7%, para uma razão óleo/álcool de 1:8, 30% de co-solvente (hexano, v/v), reação durante 48h a 35 ºC, obtendo-se apenas 46,1% de ésteres. Por fim, a qualidade do biodiesel foi ainda avaliada, de acordo com as especificações da norma EN 14214, através das determinações de densidade, viscosidade, ponto de inflamação, teor de água, corrosão ao cobre, índice de acidez, índice de iodo, teor de sódio (Na+) e potássio (K+), CFPP e poder calorífico. Na Europa, os ésteres etílicos não têm, neste momento, norma que os regule quanto à classificação da qualidade de biodiesel. Contudo, o biodiesel produzido foi analisado de acordo com a norma europeia EN14214, norma esta que regula a qualidade dos ésteres metílicos, sendo possível concluir que nenhum dos parâmetros avaliados se encontra em conformidade com a mesma.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The reduction of luvastatin (FLV) at a hanging mercury-drop electrode (HMDE) was studied by square-wave adsorptive-stripping voltammetry (SWAdSV). FLV can be accumulated and reduced at the electrode, with a maximum peak current intensity at a potential of approximately 1.26V vs. AgCl=Ag, in an aqueous electrolyte solution of pH 5.25. The method shows linearity between peak current intensity and FLV concentration between 1.0 10 8 and 2.7 10 6 mol L 1. Limits of detection (LOD) and quantification (LOQ) were found to be 9.9 10 9 mol L 1 and 3.3 10 8 mol L 1, respectively. Furthermore, FLV oxidation at a glassy carbon electrode surface was used for its hydrodynamic monitoring by amperometric detection in a flow-injection system. The amperometric signal was linear with FLV concentration over the range 1.0 10 6 to 1.0 10 5 mol L 1, with an LOD of 2.4 10 7 mol L 1 and an LOQ of 8.0 10 7 mol L 1. A sample rate of 50 injections per hour was achieved. Both methods were validated and showed to be precise and accurate, being satisfactorily applied to the determination of FLV in a commercial pharmaceutical.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A flow injection analysis (FIA) system having a chlormequat selective electrode is proposed. Several electrodes with poly(vinyl chloride) based membranes were constructed for this purpose. Comparative characterization suggestedthe use of membrane with chlormequat tetraphenylborate and dibutylphthalate. On a single-line FIA set-up, operating with 1x10-2 mol L-1 ionic strength and 6.3 pH, calibration curves presented slopes of 53.6±0.4mV decade-1 within 5.0x10-6 and1.0x10-3 mol L-1, andsquaredcorrelation coefficients >0.9953. The detection limit was 2.2x10-6 mol L-1 and the repeatability equal to ±0.68mV (0.7%). A dual-channel FIA manifold was therefore constructed, enabling automatic attainment of previous ionic strength andpH conditions and thus eliminating sample preparation steps. Slopes of 45.5±0.2mV decade -1 along a concentration range of 8.0x10-6 to 1.0x10-3 mol L-1 with a repeatability ±0.4mV (0.69%) were obtained. Analyses of real samples were performed, and recovery gave results ranging from 96.6 to 101.1%.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aflowinjection squarewave cathodic stripping voltammetric method has been developed for the determination of sertraline in a pharmaceutical preparation. The method shows linearity between peak current intensity and sertraline concentration for the interval between 0.20×10−6 and 1.20×10−6 mol L−1. Limits of detection and quantification were found to be 1.5×10−7 and 5.0×10−7 mol L−1, respectively. Up to 70 samples per hour can be analysed with a good precision (R.S.D. = 2.5%). The proposed method was successfully applied to the determination of sertraline in a commercial product. In the voltammetric determination of sertraline in flow, a high sample rate is obtained at reduced costs, opening the possibility to compete with the chromatographic methods generally used for this analysis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A procedure for the determination of seven indicator PCBs in soils and sediments using microwave-assisted extraction (MAE) and headspace solid-phase microextraction (HS-SPME) prior to GC-MS/MS is described. Optimization of the HS-SPME was carried out for the most important parameters such as extraction time, sample volume and temperature. The adopted methodology has reduced consumption of organic solvents and analysis runtime. Under the optimized conditions, the method detection limit ranged from 0.6 to 1 ng/g when 5 g of sample was extracted, the precision on real samples ranged from 4 to 21% and the recovery from 69 to 104%. The proposed method, which included the analysis of a certified reference material in its validation procedure, can be extended to several other PCBs and used in the monitoring of soil or sediments for the presence of PCBs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the last two decades, there was a proliferation of programming exercise formats that hinders interoperability in automatic assessment. In the lack of a widely accepted standard, a pragmatic solution is to convert content among the existing formats. BabeLO is a programming exercise converter providing services to a network of heterogeneous e-learning systems such as contest management systems, programming exercise authoring tools, evaluation engines and repositories of learning objects. Its main feature is the use of a pivotal format to achieve greater extensibility. This approach simplifies the extension to other formats, just requiring the conversion to and from the pivotal format. This paper starts with an analysis of programming exercise formats representative of the existing diversity. This analysis sets the context for the proposed approach to exercise conversion and to the description of the pivotal data format. The abstract service definition is the basis for the design of BabeLO, its components and web service interface. This paper includes a report on the use of BabeLO in two concrete scenarios: to relocate exercises to a different repository, and to use an evaluation engine in a network of heterogeneous systems.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An approach for the analysis of uncertainty propagation in reliability-based design optimization of composite laminate structures is presented. Using the Uniform Design Method (UDM), a set of design points is generated over a domain centered on the mean reference values of the random variables. A methodology based on inverse optimal design of composite structures to achieve a specified reliability level is proposed, and the corresponding maximum load is outlined as a function of ply angle. Using the generated UDM design points as input/output patterns, an Artificial Neural Network (ANN) is developed based on an evolutionary learning process. Then, a Monte Carlo simulation using ANN development is performed to simulate the behavior of the critical Tsai number, structural reliability index, and their relative sensitivities as a function of the ply angle of laminates. The results are generated for uniformly distributed random variables on a domain centered on mean values. The statistical analysis of the results enables the study of the variability of the reliability index and its sensitivity relative to the ply angle. Numerical examples showing the utility of the approach for robust design of angle-ply laminates are presented.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mestrado em Engenharia Química - Ramo Tecnologias de Protecção Ambiental

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents the preliminary work of an approach where Fuzzy Boolean Nets (FBN) are being used to extract qualitative knowledge regarding the effect of prescribed fire burning on soil chemical physical properties. FBN were chosen due to the scarcity on available quantitative data.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Portuguese northern forests are often and severely affected by wildfires during the summer season. These occurrences affect significant and rudely all ecosystems, namely soil, fauna and flora. Preventive actions such as prescribed burnings and clear-cut logging are frequently used and have showed a significant reduction of the natural wildfires occurrences. In Portugal, and due to some technical and operational conditions, prescribed burnings in forests are the most common preventive action used to reduce the existing fuel hazard. The overall impacts of this preventive action on Portuguese ecosystems are complex and not fully understood. This work reports to the study of a prescribed burning impact in soil chemical properties, namely pH, humidity and organic matter, by monitoring the soil self-recovery capacity. The experiments were carried out in soil cover over a natural site of Andaluzitic schist, in Gramelas, Caminha, Portugal, who was able to maintain itself intact from prescribed burnings from four years. The composed soil samples were collected from five plots at three different layers (0-3cm, 3-6cm and 6-18cm) 1 day before prescribed fire and after the prescribed fire. The results have shown that the dynamic equilibrium in soil was affected significantly.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A novel sensitive electrochemical sensor was developed by electropolymerization of pyrrole(PY)and molecularly imprinted polymer (MIP)which was synthesized onto a glassy carbon electrode (GCE) in aqueous solution using cyclic voltammetry in the presence of Trimethoprim (TMP) as template molecules. Furthermore,a previous electrode modification was performed by deposition of a suspension of graphene on the electrode's surface. The performance of the imprinted and non-imprinted (NIP) films was evaluated by impedance spectroscopy (EIS) and cyclic voltammetry (CV) of a ferric solution. The molecularly imprinted film exhibited a high selectivity and sensitivity toward TMP. The sensor presented a linear range, between peak current intensity and logarithm of TMP concentration between 1.0x10-6 and 1.0x10-4 M. The results were accurate (with recoveries higher than 94%), precise (with standard deviations less than 5%) and the detection limit was 1.3x10-7 M. The new sensor is selective, simple to construct and easy to operate. The MIP sensor was successfully applied to quantify TMP in urinesamples.