108 resultados para precise positioning

em Instituto Politécnico do Porto, Portugal


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The goal of the work presented in this paper is to provide mobile platforms within our campus with a GPS based data service capable of supporting precise outdoor navigation. This can be achieved by providing campus-wide access to real time Differential GPS (DGPS) data. As a result, we designed and implemented a three-tier distributed system that provides Internet data links between remote DGPS sources and the campus and a campus-wide DGPS data dissemination service. The Internet data link service is a two-tier client/server where the server-side is connected to the DGPS station and the client-side is located at the campus. The campus-wide DGPS data provider disseminates the DGPS data received at the campus via the campus Intranet and via a wireless data link. The wireless broadcast is intended for portable receivers equipped with a DGPS wireless interface and the Intranet link is provided for receivers with a DGPS serial interface. The application is expected to provide adequate support for accurate outdoor campus navigation tasks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mestrado em Engenharia Electrotécnica e de Computadores.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A presente dissertação apresenta uma solução para o problema de modelização tridimensional de galerias subterrâneas. O trabalho desenvolvido emprega técnicas provenientes da área da robótica móvel para obtenção um sistema autónomo móvel de modelização, capaz de operar em ambientes não estruturados sem acesso a sistemas de posicionamento global, designadamente GPS. Um sistema de modelização móvel e autónomo pode ser bastante vantajoso, pois constitui um método rápido e simples de monitorização das estruturas e criação de representações virtuais das galerias com um elevado nível de detalhe. O sistema de modelização desloca-se no interior dos túneis para recolher informações sensoriais sobre a geometria da estrutura. A tarefa de organização destes dados com vista _a construção de um modelo coerente, exige um conhecimento exacto do percurso praticado pelo sistema, logo o problema de localização da plataforma sensorial tem que ser resolvido. A formulação de um sistema de localização autónoma tem que superar obstáculos que se manifestam vincadamente nos ambientes underground, tais como a monotonia estrutural e a já referida ausência de sistemas de posicionamento global. Neste contexto, foi abordado o conceito de SLAM (Simultaneous Loacalization and Mapping) para determinação da localização da plataforma sensorial em seis graus de liberdade. Seguindo a abordagem tradicional, o núcleo do algoritmo de SLAM consiste no filtro de Kalman estendido (EKF { Extended Kalman Filter ). O sistema proposto incorpora métodos avançados do estado da arte, designadamente a parametrização em profundidade inversa (Inverse Depth Parametrization) e o método de rejeição de outliers 1-Point RANSAC. A contribuição mais importante do método por nós proposto para o avanço do estado da arte foi a fusão da informação visual com a informação inercial. O algoritmo de localização foi testado com base em dados reais, adquiridos no interior de um túnel rodoviário. Os resultados obtidos permitem concluir que, ao fundir medidas inerciais com informações visuais, conseguimos evitar o fenómeno de degeneração do factor de escala, comum nas aplicações de localização através de sistemas puramente monoculares. Provámos simultaneamente que a correcção de um sistema de localização inercial através da consideração de informações visuais é eficaz, pois permite suprimir os desvios de trajectória que caracterizam os sistemas de dead reckoning. O algoritmo de modelização, com base na localização estimada, organiza no espaço tridimensional os dados geométricos adquiridos, resultando deste processo um modelo em nuvem de pontos, que posteriormente _e convertido numa malha triangular, atingindo-se assim uma representação mais realista do cenário original.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To avoid additional hardware deployment, indoor localization systems have to be designed in such a way that they rely on existing infrastructure only. Besides the processing of measurements between nodes, localization procedure can include the information of all available environment information. In order to enhance the performance of Wi-Fi based localization systems, the innovative solution presented in this paper considers also the negative information. An indoor tracking method inspired by Kalman filtering is also proposed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Absolute positioning – the real time satellite based positioning technique that relies solely on global navigation satellite systems – lacks accuracy for several real time application domains. To provide increased positioning quality, ground or satellite based augmentation systems can be devised, depending on the extent of the area to cover. The underlying technique – multiple reference station differential positioning – can, in the case of ground systems, be further enhanced through the implementation of the virtual reference station concept. Our approach is a ground based system made of a small-sized network of three stations where the concept of virtual reference station was implemented. The stations provide code pseudorange corrections, which are combined using a measurement domain approach inversely proportional to the distance from source station to rover. All data links are established trough the Internet.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The goal of the this paper is to show that the DGPS data Internet service we designed and developed provides campus-wide real time access to Differential GPS (DGPS) data and, thus, supports precise outdoor navigation. First we describe the developed distributed system in terms of architecture (a three tier client/server application), services provided (real time DGPS data transportation from remote DGPS sources and campus wide data dissemination) and transmission modes implemented (raw and frame mode over TCP and UDP). Then we present and discuss the results obtained and, finally, we draw some conclusions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we describe a low cost distributed system intended to increase the positioning accuracy of outdoor navigation systems based on the Global Positioning System (GPS). Since the accuracy of absolute GPS positioning is insufficient for many outdoor navigation tasks, another GPS based methodology – the Differential GPS (DGPS) – was developed in the nineties. The differential or relative positioning approach is based on the calculation and dissemination of the range errors of the received GPS satellites. GPS/DGPS receivers correlate the broadcasted GPS data with the DGPS corrections, granting users increased accuracy. DGPS data can be disseminated using terrestrial radio beacons, satellites and, more recently, the Internet. Our goal is to provide mobile platforms within our campus with DGPS data for precise outdoor navigation. To achieve this objective, we designed and implemented a three-tier client/server distributed system that, first, establishes Internet links with remote DGPS sources and, then, performs campus-wide dissemination of the obtained data. The Internet links are established between data servers connected to remote DGPS sources and the client, which is the data input module of the campus-wide DGPS data provider. The campus DGPS data provider allows the establishment of both Intranet and wireless links within the campus. This distributed system is expected to provide adequate support for accurate outdoor navigation tasks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The accuracy of the Navigation Satellite Timing and Ranging (NAVSTAR) Global Positioning System (GPS) measurements is insufficient for many outdoor navigation tasks. As a result, in the late nineties, a new methodology – the Differential GPS (DGPS) – was developed. The differential approach is based on the calculation and dissemination of the range errors of the GPS satellites received. GPS/DGPS receivers correlate the broadcasted GPS data with the DGPS corrections, granting users increased accuracy. DGPS data can be disseminated using terrestrial radio beacons, satellites and, more recently, the Internet. Our goal is to provide mobile platforms within our campus with DGPS data for precise outdoor navigation. To achieve this objective, we designed and implemented a three-tier client/server distributed system that establishes Internet links with remote DGPS sources and performs campus-wide dissemination of the obtained data. The Internet links are established between data servers connected to remote DGPS sources and the client, which is the data input module of the campus-wide DGPS data provider. The campus DGPS data provider allows the establishment of both Intranet and wireless links within the campus. This distributed system is expected to provide adequate support for accurate (submetric) outdoor navigation tasks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The underground scenarios are one of the most challenging environments for accurate and precise 3d mapping where hostile conditions like absence of Global Positioning Systems, extreme lighting variations and geometrically smooth surfaces may be expected. So far, the state-of-the-art methods in underground modelling remain restricted to environments in which pronounced geometric features are abundant. This limitation is a consequence of the scan matching algorithms used to solve the localization and registration problems. This paper contributes to the expansion of the modelling capabilities to structures characterized by uniform geometry and smooth surfaces, as is the case of road and train tunnels. To achieve that, we combine some state of the art techniques from mobile robotics, and propose a method for 6DOF platform positioning in such scenarios, that is latter used for the environment modelling. A visual monocular Simultaneous Localization and Mapping (MonoSLAM) approach based on the Extended Kalman Filter (EKF), complemented by the introduction of inertial measurements in the prediction step, allows our system to localize himself over long distances, using exclusively sensors carried on board a mobile platform. By feeding the Extended Kalman Filter with inertial data we were able to overcome the major problem related with MonoSLAM implementations, known as scale factor ambiguity. Despite extreme lighting variations, reliable visual features were extracted through the SIFT algorithm, and inserted directly in the EKF mechanism according to the Inverse Depth Parametrization. Through the 1-Point RANSAC (Random Sample Consensus) wrong frame-to-frame feature matches were rejected. The developed method was tested based on a dataset acquired inside a road tunnel and the navigation results compared with a ground truth obtained by post-processing a high grade Inertial Navigation System and L1/L2 RTK-GPS measurements acquired outside the tunnel. Results from the localization strategy are presented and analyzed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work presents an automatic calibration method for a vision based external underwater ground-truth positioning system. These systems are a relevant tool in benchmarking and assessing the quality of research in underwater robotics applications. A stereo vision system can in suitable environments such as test tanks or in clear water conditions provide accurate position with low cost and flexible operation. In this work we present a two step extrinsic camera parameter calibration procedure in order to reduce the setup time and provide accurate results. The proposed method uses a planar homography decomposition in order to determine the relative camera poses and the determination of vanishing points of detected lines in the image to obtain the global pose of the stereo rig in the reference frame. This method was applied to our external vision based ground-truth at the INESC TEC/Robotics test tank. Results are presented in comparison with an precise calibration performed using points obtained from an accurate 3D LIDAR modelling of the environment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The main purpose of this study was to examine the applicability of geostatistical modeling to obtain valuable information for assessing the environmental impact of sewage outfall discharges. The data set used was obtained in a monitoring campaign to S. Jacinto outfall, located off the Portuguese west coast near Aveiro region, using an AUV. The Matheron’s classical estimator was used the compute the experimental semivariogram which was fitted to three theoretical models: spherical, exponential and gaussian. The cross-validation procedure suggested the best semivariogram model and ordinary kriging was used to obtain the predictions of salinity at unknown locations. The generated map shows clearly the plume dispersion in the studied area, indicating that the effluent does not reach the near by beaches. Our study suggests that an optimal design for the AUV sampling trajectory from a geostatistical prediction point of view, can help to compute more precise predictions and hence to quantify more accurately dilution. Moreover, since accurate measurements of plume’s dilution are rare, these studies might be very helpful in the future for validation of dispersion models.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este estudo tem como objectivo descrever a Unidade de cuidados intensivos e intermédios respiratórios do Hospital Clínico em Barcelona de forma a caracterizá-la tanto ao nível de recursos materiais e humanos como em termos de protocolos usados. Esta unidade é considerada uma das melhores da Europa, dispondo da mais alta tecnologia, desenvolvendo protocolos baseados na evidência de forma a reduzir ao máximo a taxa de mortalidade neste local. O staff médico sempre em constante actualização, trabalhando muito no campo da investigação. Por outro lado, a fisioterapia integrante no Instituto Clínico do Tórax realiza menos investigação investindo mais no tratamento de doentes não intubados, tendo como técnicas de eleição posicionamento, mobilização, expiração forçada e hidratação oral. Em relação à VNI, muitos dos estudos referentes a este tema foram realizados pelo staff médico deste Hospital. O staff de fisioterapia é responsável pela adaptação da VNI nos pacientes hipercápnicos. Em conclusão, o número e tempo limitado de fisioterapeutas na unidade não contribuem para a aplicação de novas técnicas que requerem a intervenção de dois fisioterapeutas. Palavras-chave: unidade de cuidados intensivos respiratórios, unidade de cuidados intermédios respiratórios, VNI, papel dos fisioterapeutas respiratórios.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O estudo do comportamento motor, nomeadamente as áreas do desenvolvimento e controlo motor, têm permitido fundamentar a prática da terapia ocupacional, proporcionando um entendimento mais abrangente de aspetos relacionados com a análise de movimento. Todavia, o processo de análise de atividades, por norma, é realizado de forma empírica, principalmente devido à carência de métodos que avaliem de forma objetiva e precisa o comportamento motor e, consequentemente, os movimentos realizados no desempenho de atividades. Neste sentido, este estudo pretendeu encontrar padrões motores em crianças entre os nove e os dez anos de idade, com desenvolvimento normal, que traduzam o desempenho de uma tarefa motora funcional, com recurso ao sistema de captura e parametrização do movimento em tempo real BioStage®. Por outro lado, tentou-se perceber se o sistema poderia revelar-se um contributo para a prática da terapia ocupacional, possibilitando a obtenção de dados que possam ser utilizados na clínica. As tarefas selecionadas para análise foram os cinco lançamentos propostos pelo Bruininks-Oseretsky Test of Motor Proficiency, que consistem no lançamento por baixo uni e bilateral, lançamento ao chão uni e bilateral e lançamento ao alvo (unilateral). Os resultados encontrados apontam que aos nove e dez anos existem padrões motores similares entre as crianças, no entanto ainda se nota uma ligeira variabilidade no comportamento. Aferiu-se, também, que a idade, sexo e prática de exercício físico podem influenciar os padrões utilizados, estando de acordo com a literatura. O sistema BioStage® mostrou-se uma ferramenta eficaz para a análise de movimento, providenciando informação detalhada sobre o comportamento motor das crianças, no decorrer das tarefas. Deste modo, pode ser uma mais-valia para a prática da terapia ocupacional, podendo contribuir para uma análise de atividades mais precisa, objetiva e fundamentada.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação para a obtenção do Grau de Mestre em Contabilidade e Finanças Orientador: Dr. Paulo Filipe Teixeira Aguiar

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação para a obtenção do Grau de Mestre em Contabilidade e Finanças Orientador: Mestre Adalmiro Álvaro Malheiro de Castro Andrade Pereira