8 resultados para polyvinyl acetate

em Instituto Politécnico do Porto, Portugal


Relevância:

10.00% 10.00%

Publicador:

Resumo:

GOAL: The manufacturing and distribution of strips of instant thin - layer chromatography with silica gel (ITLC - SG) (reference method) is currently discontinued so there is a need for an alternative method f or the determination of radiochemical purity (RCP) of 99m Tc - tetrofosmin. This study aims to compare five alternative methods proposed by the producer to determine the RCP of 99m Tc - tetrofosmin. METHODS: Nineteen vials of tetrofosmin were radiolabelled with 99m Tc and the percentages of the RCP were determined. Five different methods were compared with the standard RCP testing method (ITLC - SG, 2x20 cm): Whatman 3MM (1x10 cm) with acetone and dichloro - methane (method 1); Whatman 3MM (1x1 0 cm) with ethyl acetate (method 2); aluminum oxide - coated plastic thin - layer chromatography (TLC) plate (1x10 cm) and ethanol (method 3); Whatman 3MM (2x20 cm) with acetone and dichloro - methane (method 4); solid - phase extraction method C18 cartridge (meth od 5). RESULTS: The average values of RCP were 95,30% ± 1,28% (method 1), 93,95 ± 0,61% (method 2), 96,85% ± 0,93% (method 3), 92,94% ± 0,99% (method 4) and 96,25% ± 2,57% (method 5) (n=12 each), and 93,15% ± 1,13% for the standard method (n=19). There we re statistical significant differences in the values obtained for methods 1 (P=0,001), 3 (P=0,000) and 5 (P=0,004), and there were no statistical significant differences in the values obtained for methods 2 (P=0,113) and 4 (P=0,327). CONCLUSION: From the results obtained, methods 2 and 4 showed a higher correlation with the standard method. Unlike method 4, method 2 is less time - consuming than the reference method and can overcome the problems associated with the solvent toxicity. The remaining methods (1, 3 and 5) tended to overestimate RCP value compared to the standard method.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A flow injection analysis (FIA) system comprising a tartrate- (TAT) selective electrode has been developed for determination of tartaric acid in wines. Several electrodes constructed for this purpose had a PVC membrane with a complex of quaternary ammonium and TAT as anion exchanger, a phenol derivative as additive, and a more or less polar mediator solvent. Characterization of the electrodes showed behavior was best for membranes with o-nitrophenyl octyl ether as solvent. On injection of 500 μL into a phosphate buffer carrier (pH = 3.1; ionic strength 10–2 mol/L) flowing at 3 mL/min, the slope was 58.06 ± 0.6 with a lower limit of linear range of 5.0 × 10–4 mol/L TAT and R2 = 0.9989. The interference of several species, e.g. chloride, bromide, iodide, nitrate, gallic acid, tannin, sucrose, glucose, fructose, acetate, and citrate, was evaluated in terms of potentiometric selectivity coefficients. The Hofmeister series was followed for inorganic species and the most interfering organic ion was citrate. When red and white wines were analyzed and the results compared with those from an independent method they were found to be accurate, with relative standard deviations below 5.0%.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O crescimento populacional esperado para os próximos anos conduzirá à necessidade de aumentar a produção agrícola de modo a satisfazer o aumento da procura. Nos últimos anos tem-se assistido a uma evolução tecnológica nos sistemas de produção que tem permitido aumentar a produtividade agrícola, por vezes à custa de elevados consumos de energia e com práticas nem sempre ambientalmente corretas. Os desafios que se colocam atualmente são no sentido de melhorar a conservação de recursos escassos, como o solo e a água, de aumentar a eficiência de uso de fatores de produção, de encontrar novas culturas, do desenvolvimento da biotecnologia, da diminuição dos consumos energéticos e de melhorar ainda mais as tecnologias associadas à produção. De maneira a responder aos desafios emergentes da procura por alimentos, da escassez de terrenos agrícolas aráveis bem como da existência de pragas de insetos e de ervas daninhas, os pesticidas tem vindo a ser usados com maior frequência, tendo-se assistido a uma contaminação dos solos e águas subterrâneas, causando deste modo um risco para a saúde dos seres vivos. Neste sentido, vários fabricantes de pesticidas estão a desenvolver novas formulações contendo pesticidas encapsulados em nanopartículas como modo de aumentar a sua solubilidade em água, biodisponibilidade, volatilidade, estabilidade e eficácia. tendo por objetivo um desenvolvimento sustentável. Neste trabalho, procedeu-se ao estudo do encapsulamento do herbicida Oxadiargil (5-terc-butil-3-[2,4-dicloro-5-(2-propiniloxi)fenil]-1,3,4-oxadiazol-2(3H)-ona) com a 2-hidroxipropil-β-ciclodextrina (HP-β-CD). O estudo da formação do complexo de inclusão Oxadiargil - HP-β-CD foi realizado em diferentes meios, água desionizada, tampão acetato pH = 3,46 e pH = 5,34 e tampão fosfato pH = 7,45, com o objetivo de determinar e comparar a sua constante de estabilidade. Verificou-se, em qualquer dos casos, a ocorrência de uma relação linear entre o aumento da solubilidade do Oxadiargil e o aumento da concentração de HP-β-CD, com um declive inferior a um, o que indicia a formação de um complexo na proporção estequiométrica de 1:1. Os resultados obtidos permitiram concluir que o processo de complexação Oxadiargil - HP-β-CD não é muito influenciado pela constituição e pelo pH do meio. De facto, as constantes de estabilidade obtidas para a água desionizada e soluções-tampão pH = 3,46, pH = 5,34 e pH = 7,45 foram de 919 ± 25, 685 ± 13, 623 ± 17 e 753 ± 9, respetivamente. A solubilidade do complexo obtido nos estudos realizados, em diferentes meios, é cerca de 23 a 32 vezes superior à observada para o Oxadiargil livre. De forma a caracterizar o complexo Oxadiargil - HP-β-CD procedeu-se à sua síntese utilizando o método de “kneading”. O composto obtido foi caracterizado por Ressonância Magnética Nuclear (RMN) tendo-se confirmado a formação de um complexo de inclusão na proporção estequiométrica de 1:1. O complexo obtido é mais solúvel e porventura mais estável quimicamente. O encapsulamento permite uma redução da aplicação dos pesticidas diminuindo assim os custos e o impacto negativo no ambiente. Com a nanotecnologia é possível a libertação controlada dos pesticidas, aumentando a sua eficácia e fornecendo os meios necessários para um desenvolvimento sustentável.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A novel surface molecularly-imprinted (MI) material to detect myoglobin (Myo) using gold screen printed electrodes (SPE) was developed. The sensitive detection was carry out by introducing a carboxylic polyvinyl chloride (PVC-COOH) layer on gold SPE surface. Myo was attached to the surface of gold SPE/PVC-COOH and the vacant spaces around it were filled by polymerizing acrylamide and N,N-methylenebisacrylamide (cross-linker). This polymerization was initiated by ammonium persulphate. After removing the template, the obtained material was able to rebind Myo and discriminate it among other interfering species. Various characterization techniques including electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) confirmed the surface modification. This sensor seemed a promising tool for screening Myo in point-of-care.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Microcystin-LR (MC-LR) is a dangerous toxin found in environmental waters, quantified by high performance liquid chromatography and/or enzyme-linked immunosorbent assays. Quick, low cost and on-site analysis is thus required to ensure human safety and wide screening programs. This work proposes label-free potentiometric sensors made of solid-contact electrodes coated with a surface imprinted polymer on the surface of Multi-Walled Carbon NanoTubes (CNTs) incorporated in a polyvinyl chloride membrane. The imprinting effect was checked by using non-imprinted materials. The MC-LR sensitive sensors were evaluated, characterized and applied successfully in spiked environmental waters. The presented method offered the advantages of low cost, portability, easy operation and suitability for adaptation to flow methods.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Sulfamethoxazole (SMX) is among the antibiotics employed in aquaculture for prophylactic and therapeutic reasons. Environmental and food spread may be prevented by controlling its levels in several stages of fish farming. The present work proposes for this purpose new SMX selective electrodes for the potentiometric determination of this sulphonamide in water. The selective membranes were made of polyvinyl chloride (PVC) with tetraphenylporphyrin manganese (III) chloride or cyclodextrin-based acting as ionophores. 2-nitrophenyl octyl ether was employed as plasticizer and tetraoctylammonium, dimethyldioctadecylammonium bromide or potassium tetrakis (4-chlorophenyl) borate was used as anionic or cationic additive. The best analytical performance was reported for ISEs of tetraphenylporphyrin manganese (III) chloride with 50% mol of potassium tetrakis (4-chlorophenyl) borate compared to ionophore. Nersntian behaviour was observed from 4.0 × 10−5 to 1.0 × 10−2 mol/L (10.0 to 2500 µg/mL), and the limit of detection was 1.2 × 10−5 mol/L (3.0 µg/mL). In general, the electrodes displayed steady potentials in the pH range of 6 to 9. Emf equilibrium was reached before 15 s in all concentration levels. The electrodes revealed good discriminating ability in environmental samples. The analytical application to contaminated waters showed recoveries from 96 to 106%.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Sulfadiazine is an antibiotic of the sulfonamide group and is used as a veterinary drug in fish farming. Monitoring it in the tanks is fundamental to control the applied doses and avoid environmental dissemination. Pursuing this goal, we included a novel potentiometric design in a flow-injection assembly. The electrode body was a stainless steel needle veterinary syringe of 0.8-mm inner diameter. A selective membrane of PVC acted as a sensory surface. Its composition, the length of the electrode, and other flow variables were optimized. The best performance was obtained for sensors of 1.5-cm length and a membrane composition of 33% PVC, 66% onitrophenyloctyl ether, 1% ion exchanger, and a small amount of a cationic additive. It exhibited Nernstian slopes of 61.0 mV decade-1 down to 1.0×10-5 mol L-1, with a limit of detection of 3.1×10-6 mol L-1 in flowing media. All necessary pH/ionic strength adjustments were performed online by merging the sample plug with a buffer carrier of 4-(2-hydroxyethyl)-1-piperazineethanesulfonic acid, pH 4.9. The sensor exhibited the advantages of a fast response time (less than 15 s), long operational lifetime (60 days), and good selectivity for chloride, nitrite, acetate, tartrate, citrate, and ascorbate. The flow setup was successfully applied to the analysis of aquaculture waters. The analytical results were validated against those obtained with liquid chromatography–tandem mass spectrometry procedures. The sampling rate was about 84 samples per hour and recoveries ranged from 95.9 to 106.9%.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Enrofloxacin (ENR) is an antimicrobial used both in humans and in food producing species. Its control is required in farmed species and their surroundings in order to reduce the prevalence of antibiotic resistant bacteria. Thus, a new biomimetic sensor enrofloxacin is presented. An artificial host was imprinted in specific polymers. These were dispersed in 2-nitrophenyloctyl ether and entrapped in a poly(vinyl chloride) matrix. The potentiometric sensors exhibited a near-Nernstian response. Slopes expressing mV/Δlog([ENR]/M) varied within 48–63. The detection limits ranged from 0.28 to 1.01 µg mL−1. Sensors were independent from the pH of test solutions within 4–7. Good selectivity was observed toward potassium, calcium, barium, magnesium, glycine, ascorbic acid, creatinine, norfloxacin, ciprofloxacin, and tetracycline. In flowing media, the biomimetic sensors presented good reproducibility (RSD of ± 0.7%), fast response, good sensitivity (47 mV/Δlog([ENR]/M), wide linear range (1.0 × 10−5–1.0 × 10−3 M), low detection limit (0.9 µg mL−1), and a stable baseline for a 5 × 10−2 M acetate buffer (pH 4.7) carrier. The sensors were used to analyze fish samples. The method offered the advantages of simplicity, accuracy, and automation feasibility. The sensing membrane may contribute to the development of small devices allowing in vivo measurements of enrofloxacin or parent-drugs.