16 resultados para plant and equipment (PPE),
em Instituto Politécnico do Porto, Portugal
Resumo:
Coal contains trace quantities of natural radionuclides such as Th-232, U-235, U-238, as well as their radioactive decay products and 40K. These radionuclides can be released as fly ash in atmospheric emissions from coal-fired power plants, dispersed into the environment and deposited on the surrounding top soils. Therefore, the natural radiation background level is enhanced and consequently increase the total dose for the nearby population. A radiation monitoring programme was used to assess the external dose contribution to the natural radiation background, potentially resulting from the dispersion of coal ash in past atmospheric emissions. Radiation measurements were carried out by gamma spectrometry in the vicinity of a Portuguese coal-fired power plant. The radiation monitoring was achieved both on and off site, being the boundary delimited by a 20 km circle centered in the stacks of the coal plant. The measured radionuclides concentrations for the uranium and thorium series ranged from 7.7 to 41.3 Bq/kg for Ra-226 and from 4.7 to 71.6 Bq/kg for Th-232, while K-40 concentrations ranged from 62.3 to 795.1 Bq/kg. The highest values were registered near the power plant and at distances between 6 and 20 km from the stacks, mainly in the prevailing wind direction. The absorbed dose rates were calculated for each sampling location: 13.97-84.00 ηGy/h, while measurements from previous studies carried out in 1993 registered values in the range of 16.6-77.6 ηGy/h. The highest values were registered at locations in the prevailing wind direction (NW-SE). This study has been primarily done to assess the radiation dose rates and exposure to the nearby population in the surroundings of a coal-fired power plant. The results suggest an enhancement or at least an influence in the background radiation due to the coal plant past activities.
Resumo:
Gamma radiations measurements were carried out in the vicinity of a coal-fired power plant located in the southwest coastline of Portugal. Two different gamma detectors were used to assess the environmental radiation within a circular area of 20 km centred in the coal plant: a scintillometer (SPP2 NF, Saphymo) and a high purity germanium detector (HPGe, Canberra). Fifty urban and suburban measurements locations were established within the defined area and two measurements campaigns were carried out. The results of the total gamma radiation ranged from 20.83 to 98.33 counts per second (c.p.s.) for both measurement campaigns and outdoor doses rates ranged from 77.65 to 366.51 Gy/h. Natural emitting nuclides from the U-238 and Th-232 decay series were identified as well as the natural emitting nuclide K-40. The radionuclide concentration from the uranium and thorium series determined by gamma spectrometry ranged from 0.93 to 73.68 Bq/kg, while for K-40 the concentration ranged from 84.14 to 904.38 Bq/kg. The obtained results were used primarily to define the variability in measured environmental radiation and to determine the coal plant’s influence in the measured radiation levels. The highest values were measured at two locations near the power plant and at locations between the distance of 6 and 20 km away from the stacks, mainly in the prevailing wind direction. The results showed an increase or at least an influence from the coal-fired plant operations, both qualitatively and quantitatively.
Resumo:
One of the most difficult problems that face researchers experimenting with complex systems in real world applications is the Facility Layout Design Problem. It relies with the design and location of production lines, machinery and equipment, inventory storage and shipping facilities. In this work it is intended to address this problem through the use of Constraint Logic Programming (CLP) technology. The use of Genetic Algorithms (GA) as optimisation technique in CLP environment is also an issue addressed. The approach aims the implementation of genetic algorithm operators following the CLP paradigm.
Resumo:
O presente trabalho foi elaborado no âmbito da Dissertação Final de Mestrado do curso de Engenharia Mecânica – Gestão Industrial do Instituto Superior de Engenharia do Porto. Este foi realizado numa empresa da indústria de pneus, a Continental Mabor S.A.. Nos dias atuais, a indústria esta cada vez mais competitiva, os custos e os prazos da entrega são cada vez mais reduzidos e a qualidade cada vez mais exigente, assim sendo, é imprescindível uma constante melhoria do sistema produtivo. Este fato fez com que o presente trabalho tivesse como principal objetivo determinar o estado atual e delinear um plano de melhoria para um equipamento (Extrusora de pisos nº6), recentemente instalado na fábrica mas oriundo de outra fábrica do grupo, recorrendo para tal ao Lean Manufacturing e a ferramentas que lhe estão associadas. Inicialmente realizou-se uma análise e diagnóstico ao processo de extrusão de pisos na Extrusora nº6, com o intuito de avaliar todas as suas ineficiências e ainda formular um plano de melhorias para a ineficiência de maior impacto no sistema produtivo. Esta análise foi realizada em diferentes turnos e diferentes equipas de trabalho de forma a se obter uma amostra mais representativa da realidade global. Após esta análise verificou-se que as principais ineficiências eram Setup, conformidade do material, dimensões e encravamentos, entre outros. Sendo que os Setup provocam um tempo de paragem de 101 minutos por turno, escolheu-se esta perturbação como o foco do plano de melhorias a realizar posteriormente. De forma a reduzir os tempos de mudança (Setup), o autor no presente trabalho utilizou ferramentas Lean Manufacturing, principalmente o SMED. Conjuntamente com o SMED ainda foram utilizadas outras ferramentas Lean Manufacturing tais como: 5S, Gestão Visual, Problem Solving e Normalização do Método de Trabalho. Após a implementação de todas estas ferramentas obteve-se uma redução de tempos de mudança de 43% com 1 operador e 71% com 2 operadores, ou seja, reduziu-se de 40,5 minutos gastos por turno para a mudança de fieira para 23,13 min e 11,79 min respetivamente, o que corresponde a um ganho monetário anual de 63.621€ ou 105.045€, respetivamente. Com este trabalho conclui-se que a utilização de ferramentas Lean Manufacturing contribuem para a redução dos desperdícios do processo produtivo. Por isso, espera-se que este estudo seja aplicado na Extrusora nº6 e nas restantes Extrusoras de pisos existentes na fábrica, e num futuro próximo que se realize estudos semelhantes em máquinas com diferentes funções.
Resumo:
Certain materials used and produced in a wide range of non-nuclear industries contain enhanced activity concentrations of natural radionuclides. In particular, electricity production from coal is one of the major sources of increased exposure to man from enhanced naturally occurring materials. Over the past decades there has been some discussion about the elevated natural background radiation in the area near coal-fired power plants due to high uranium and thorium content present in coal. This work describes the methodology developed to assess the radiological impact due to natural radiation background increasing levels, potentially originated by a coal-fired power plant’s operation. Gamma radiation measurements have been done with two different instruments: a scintillometer (SPP2 NF, Saphymo) and a gamma ray spectrometer with energy discrimination (Falcon 5000, Canberra). A total of 40 relevant sampling points were established at locations within 20 km from the power plant: 15 urban and 25 suburban measured stations. The highest values were measured at the sampling points near to the power plant and those located in the area within the 6 and 20 km from the stacks. This may be explained by the presence of a huge coal pile (1.3 million tons) located near the stacks contributing to the dispersion of unburned coal and, on the other hand, the height of the stacks (225 m) which may influence ash’s dispersion up to a distance of 20 km. In situ gamma radiation measurements with energy discrimination identified natural emitting nuclides as well as their decay products (212Pb, 214Pb, 226Ra 232Th, 228Ac, 234Th 234Pa, 235U, etc.). This work has been primarily done to in order to assess the impact of a coal-fired power plant operation on the background radiation level in the surrounding area. According to the results, an increase or at least an influence has been identified both qualitatively and quantitatively.
Resumo:
Risk assessment is one of the main pillars of the framework directive and other directives in respect of health and safety. It is also the basis of an effective management of safety and health as it is essential to reduce work-related accidents and occupational diseases. To survey the hazards eventually present in the workplaces the usual procedures are i) gathering information about tasks/activities, employees, equipment, legislation and standards; ii) observation of the tasks and; iii) quantification of respective risks through the most adequate risk assessment among the methodologies available. From this preliminary evaluation of a welding plant and, from the different measurable parameters, noise was considered the most critical. This paper focus not only the usual way of risk assessment for noise but also another approach that may allow us to identify the technique with which a weld is being performed.
Resumo:
Mathematical models and statistical analysis are key instruments in soil science scientific research as they can describe and/or predict the current state of a soil system. These tools allow us to explore the behavior of soil related processes and properties as well as to generate new hypotheses for future experimentation. A good model and analysis of soil properties variations, that permit us to extract suitable conclusions and estimating spatially correlated variables at unsampled locations, is clearly dependent on the amount and quality of data and of the robustness techniques and estimators. On the other hand, the quality of data is obviously dependent from a competent data collection procedure and from a capable laboratory analytical work. Following the standard soil sampling protocols available, soil samples should be collected according to key points such as a convenient spatial scale, landscape homogeneity (or non-homogeneity), land color, soil texture, land slope, land solar exposition. Obtaining good quality data from forest soils is predictably expensive as it is labor intensive and demands many manpower and equipment both in field work and in laboratory analysis. Also, the sampling collection scheme that should be used on a data collection procedure in forest field is not simple to design as the sampling strategies chosen are strongly dependent on soil taxonomy. In fact, a sampling grid will not be able to be followed if rocks at the predicted collecting depth are found, or no soil at all is found, or large trees bar the soil collection. Considering this, a proficient design of a soil data sampling campaign in forest field is not always a simple process and sometimes represents a truly huge challenge. In this work, we present some difficulties that have occurred during two experiments on forest soil that were conducted in order to study the spatial variation of some soil physical-chemical properties. Two different sampling protocols were considered for monitoring two types of forest soils located in NW Portugal: umbric regosol and lithosol. Two different equipments for sampling collection were also used: a manual auger and a shovel. Both scenarios were analyzed and the results achieved have allowed us to consider that monitoring forest soil in order to do some mathematical and statistical investigations needs a sampling procedure to data collection compatible to established protocols but a pre-defined grid assumption often fail when the variability of the soil property is not uniform in space. In this case, sampling grid should be conveniently adapted from one part of the landscape to another and this fact should be taken into consideration of a mathematical procedure.
Resumo:
Mestrado em Engenharia Geotécnica e Geoambiente
Resumo:
Prostate Specific Antigen (PSA) is the biomarker of choice for screening prostate cancer throughout the population, with PSA values above 10 ng/mL pointing out a high probability of associated cancer1. According to the most recent World Health Organization (WHO) data, prostate cancer is the commonest form of cancer in men in Europe2. Early detection of prostate cancer is thus very important and is currently made by screening PSA in men over 45 years old, combined with other alterations in serum and urine parameters. PSA is a glycoprotein with a molecular mass of approximately 32 kDa consisting of one polypeptide chain, which is produced by the secretory epithelium of human prostate. Currently, the standard methods available for PSA screening are immunoassays like Enzyme-Linked Immunoabsorbent Assay (ELISA). These methods are highly sensitive and specific for the detection of PSA, but they require expensive laboratory facilities and high qualify personal resources. Other highly sensitive and specific methods for the detection of PSA have also become available and are in its majority immunobiosensors1,3-5, relying on antibodies. Less expensive methods producing quicker responses are thus needed, which may be achieved by synthesizing artificial antibodies by means of molecular imprinting techniques. These should also be coupled to simple and low cost devices, such as those of the potentiometric kind, one approach that has been proven successful6. Potentiometric sensors offer the advantage of selectivity and portability for use in point-of-care and have been widely recognized as potential analytical tools in this field. The inherent method is simple, precise, accurate and inexpensive regarding reagent consumption and equipment involved. Thus, this work proposes a new plastic antibody for PSA, designed over the surface of graphene layers extracted from graphite. Charged monomers were used to enable an oriented tailoring of the PSA rebinding sites. Uncharged monomers were used as control. These materials were used as ionophores in conventional solid-contact graphite electrodes. The obtained results showed that the imprinted materials displayed a selective response to PSA. The electrodes with charged monomers showed a more stable and sensitive response, with an average slope of -44.2 mV/decade and a detection limit of 5.8X10-11 mol/L (2 ng/mL). The corresponding non-imprinted sensors showed smaller sensitivity, with average slopes of -24.8 mV/decade. The best sensors were successfully applied to the analysis of serum samples, with percentage recoveries of 106.5% and relatives errors of 6.5%.
Resumo:
A cidade do Porto é uma das regiões do país onde é importante uma gestão sustentável e integrada dos recursos hídricos. A (re) utilização de água surge neste contexto como uma possível resposta na sua utilização como um recurso hídrico passível de ser usado beneficamente, permitindo a poupança de fontes de água convencionais e aumentando a disponibilidade dos recursos hídricos existentes para finalidades que requerem padrões de qualidade mais exigentes. O potencial desta prática no nosso país é enorme, considerando que o volume de água tratada descarregada no ano 2000 era suficiente para suprir 10% das necessidades em água para rega num ano seco, sem necessidade de armazenamento sazonal. Por outro lado, um sistema de rega, quando devidamente projetado e funcionando adequadamente, permite que a água seja aplicada com um caudal, duração e frequência que maximizam o consumo da água e nutrientes pela planta. Este projeto consiste no desenvolvimento de um Sistema de Gestão Técnica para o controlo do sistema de rega dos jardins do ISEP – Instituto Politécnico de Engenharia do Porto com recurso a um autómato programável (PLC). Pretende-se otimizar os consumos energéticos do sistema de rega tendo em conta os parâmetros de humidade, temperatura e velocidade do vento característicos do local a regar. Outros dos objetivos é controlar o processo de enchimento e de rega. Esta operação consiste no controlo das bombas e respetivos débitos e conhecimento dos caudais necessários. Pretende-se, igualmente, definir e colocar em marcha todo o equipamento necessário para a realização do projeto. Os dados coletados devem ser tratados de tal modo que possam ser realizadas análises diárias, mensais e/ou anuais. Neste trabalho foram efetuados os cálculos de dimensionamentos relativamente às necessidades hídricas da planta e necessidades de rega, entre outros.
Resumo:
A cidade do Porto é uma das regiões do país onde é importante uma gestão sustentável e integrada dos recursos hídricos. A (re) utilização de água surge neste contexto como uma possível resposta na sua utilização como um recurso hídrico passível de ser usado beneficamente, permitindo a poupança de fontes de água convencionais e aumentando a disponibilidade dos recursos hídricos existentes para finalidades que requerem padrões de qualidade mais exigentes. O potencial desta prática no nosso país é enorme, considerando que o volume de água tratada descarregada no ano 2000 era suficiente para suprir 10% das necessidades em água para rega num ano seco, sem necessidade de armazenamento sazonal. Por outro lado, um sistema de rega, quando devidamente projetado e funcionando adequadamente, permite que a água seja aplicada com um caudal, duração e frequência que maximizam o consumo da água e nutrientes pela planta. Este projeto consiste no desenvolvimento de um Sistema de Gestão Técnica para o controlo do sistema de rega dos jardins do ISEP – Instituto Politécnico de Engenharia do Porto com recurso a um autómato programável (PLC). Pretende-se otimizar os consumos energéticos do sistema de rega tendo em conta os parâmetros de humidade, temperatura e velocidade do vento característicos do local a regar. Outros dos objetivos é controlar o processo de enchimento e de rega. Esta operação consiste no controlo das bombas e respetivos débitos e conhecimento dos caudais necessários. Pretende-se, igualmente, definir e colocar em marcha todo o equipamento necessário para a realização do projeto. Os dados coletados devem ser tratados de tal modo que possam ser realizadas análises diárias, mensais e/ou anuais. Neste trabalho foram efetuados os cálculos de dimensionamentos relativamente às necessidades hídricas da planta e necessidades de rega, entre outros.
Resumo:
O elevado consumo de água associado à escassez deste recurso contribuiu para que alternativas de reutilização/reciclagem de água fossem estudadas que permitam diminuir o seu consumo e minimizar a dependência das indústrias. Monitorizar e avaliar os consumos de água, a nível industrial, é imprescindível para assegurar uma gestão sustentável dos recursos hídricos, sendo este o objetivo da presente dissertação. As alternativas encontradas na unidade industrial em estudo foram a substituição do equipamento sanitário e o aproveitamento do efluente tratado para operações de lavagem e/ou arrefecimento por contacto direto. A maioria do equipamento sanitário não é eficiente, tendo-se proposto a substituição desse sistema por um de menor consumo que permitirá uma poupança de 30 % no consumo de água, que corresponderá a 12 149,37 €/ano, sendo o retorno do investimento estimado em 3 meses. O efluente industrial na entrada da ETAR e nas diferentes etapas - tratamento primário de coagulação/floculação; tratamento secundário ou biológico em SBR; tratamento terciário de coagulação/floculação - foi caracterizado através da medição da temperatura, pH, oxigénio dissolvido e pela determinação da cor, turvação, sólidos suspensos totais (SST), azoto total, carência química de oxigénio (CQO), Carência Bioquímica de Oxigénio ao fim de 5 dias (CBO5) e razão CBO5/CQO. Esta caracterização permitiu avaliar o efluente industrial bruto que se caracteriza por um pH alcalino (8,3 ± 1,7); condutividade baixa (451 ± 200,2 μS/cm); elevada turvação (11 255 ± 8812,8 FTU); cor aparente (63 670 ± 42293,4 PtCo) e cor verdadeira (33 621 ± 19547,9 PtCo) elevadas; teores elevados de CQO (24 753 ± 11806,7 mg/L O2) SST (5 164 ± 3845,5 mg/L) e azoto total (718 mg/L) e um índice de biodegradabilidade baixo (razão CBO5/CQO de 1,4). Este estudo permitiu verificar que a eficiência global do tratamento do efluente foi 82 % na remoção da turvação, 83 % na remoção da cor aparente, 96 % na remoção da cor verdadeira, 85 % na remoção da CQO e 30 % na remoção dos SST. Quanto às eficiências de remoção associadas ao tratamento primário no que diz respeito à turvação, cor aparente, CQO e SST, apresentam valores inferiores aos referidos na literatura para o mesmo tipo de tratamento em efluentes similares. As eficiências de remoção obtidas no tratamento secundário são inferiores às do tratamento primário: turvação, cor aparente, CQO e SST, pelo que procurou-se otimizar a primeira etapa do processo de tratamento Neste estudo de otimização estudou-se a influência de cinco coagulantes – Sulfato de Alumínio, PAX XL – 10, PAX 18, cloreto de ferro e a conjugação de PAX 18 com sulfato de ferro - e seis floculantes – Superfloc A 150, Superfloc A 130, PA 1020, Ambifloc 560, Ambifloc C58 e Rifloc 54 - no tratamento físico-químico do efluente. O PAX 18 e o Ambifloc 560 UUJ foram os que apresentaram as mais elevadas eficiências de remoção (99,85 % na cor, 99,87 % na turvação, 90,12 % na CQO e 99,87 % nos SST). O custo associado a este tratamento é de 1,03 €/m3. Pela comparação com os critérios de qualidade no guia técnico ERSAR, apenas o parâmetro da CQO excede o valor, contudo o valor obtido permite diminuir os custos associados a um tratamento posterior para remoção da CQO remanescente no efluente residual tratado.
Resumo:
Um dos objetivos desta dissertação de mestrado foi avaliar o impacto ambiental do processo de tingimento usado na indústria de curtumes, em termos de volume de efluente produzido e sua carga poluente. Pretendeu-se também encontrar alternativas ao nível do processo de tingimento que levem a uma melhoria na qualidade do efluente produzido. Outro objetivo deste trabalho foi avaliar o funcionamento da ETAR existente na empresa JR Fontes, no que diz respeito aos parâmetros em estudo (carência química de oxigénio - CQO, pH, crómio e teor de sólidos suspensos totais - SST), propondo alterações que permitam respeitar os valores de emissão exigidos na licença de descarga da empresa. Verificou-se que o processo de tingimento aplicado pela empresa JR Fontes é muito poluente, em termos de carga orgânica e matéria em suspensão. Este facto é comprovado pelos resultados obtidos para os três processos estudados: Montana, Galáctico e Navak. Todos os processos apresentam um efluente com pH ácido (aproximado a 3) e valores de CQO superiores a 3550 mg O2/L, sendo o processo Navak aquele que apresenta o valor mais alto para o banho composto, 8362 mg O2/L. Relativamente ao teor de crómio, o banho de recurtume com concentração mais elevada de crómio total é o banho 1 do processo Navak, com 2297 mg/L, sendo que a concentração destes banhos é sempre elevada, igual ou superior a 746 mg/L. No que diz respeito à matéria em suspensão, o processo Navak é novamente o mais poluente, com um valor de 3842 mg SST/L, não sendo obtidos nos outros processos, valores inferiores a 1205 mg SST/L. Na realização de um processo alternativo de tingimento verificou-se que é possível diminuir a carga orgânica do efluente originado. A aplicação de recurtumes sintéticos deu origem a efluentes menos poluentes. O melhor valor obtido para a CQO foi de 1113 mg O2/L, sendo obtidos valores não superiores a 7185 mg O2/L para processos de características semelhantes aos aplicados nesta indústria. Relativamente à ETAR, apesar das restrições ao funcionamento que esta apresenta, no geral pode ser considerada eficiente, embora não consiga atingir o objetivo pretendido de remoção para a CQO, ou seja o valor de 1100 mg O2/L. Nos restantes parâmetros é cumprido o limite de emissão (350 mg SST/L, pH entre 6 e 9 e 2 mg Cr/L para o crómio total): os SST apresentam o valor de 98 mg SST/L, o crómio total de 1,2 mg Cr/L e o pH encontra-se entre 8 e 9. São aqui feitas duas abordagens para solucionar os problemas existentes na ETAR. A primeira considera um ajuste no tratamento e equipamentos existentes, através da reconstrução do tanque de equalização, da substituição do coagulante por sulfato ferroso e da reconstrução do sedimentador, assim como a substituição das tubagens por umas de maior diâmetro, solucionando assim problemas de manutenção de toda a instalação e do incumprimento da legislação. A outra abordagem implica a substituição do sistema de afinação existente, os filtros de areia e carvão ativados, por um sistema de membranas de ultrafiltração ou por dois filtros de carvão ativado. Para tratar um efluente com um valor de CQO de 3000 mg O2/L com o carvão estudado, seriam necessários 132 kg de carvão por coluna, aproveitando-se os equipamentos existentes. No caso das membranas filtrantes, estas são eficazes, reduzindo a CQO em cerca de 70%. Ao contrário do carvão, a aplicação deste sistema implicaria a aquisição de novos equipamentos. Futuramente propõe-se a avaliação dos vários tipos de reagentes usados no tingimento de couro de forma a aplicar no tratamento aqueles que produzam as características desejadas no produto final e a que apresentem um menor resultado de CQO. Propõe-se também o estudo de viabilidade da remoção de crómio dos banhos de recurtume e consequente avaliação da aplicabilidade de um tratamento biológico em substituição ou como complemento do tratamento existente.
Resumo:
Proceedings of the 13th International UFZ-Deltares Conference on Sustainable Use and Management of Soil, Sediment and Water Resources - 9–12 June 2015 • Copenhagen, Denmark