2 resultados para photon calibrator
em Instituto Politécnico do Porto, Portugal
Resumo:
Introduction: Paper and thin layer chromatography methods are frequently used in Classic Nuclear Medicine for the determination of radiochemical purity (RCP) on radiopharmaceutical preparations. An aliquot of the radiopharmaceutical to be tested is spotted at the origin of a chromatographic strip (stationary phase), which in turn is placed in a chromatographic chamber in order to separate and quantify radiochemical species present in the radiopharmaceutical preparation. There are several methods for the RCP measurement, based on the use of equipment as dose calibrators, well scintillation counters, radiochromatografic scanners and gamma cameras. The purpose of this study was to compare these quantification methods for the determination of RCP. Material and Methods: 99mTc-Tetrofosmin and 99mTc-HDP are the radiopharmaceuticals chosen to serve as the basis for this study. For the determination of RCP of 99mTc-Tetrofosmin we used ITLC-SG (2.5 x 10 cm) and 2-butanone (99mTc-tetrofosmin Rf = 0.55, 99mTcO4- Rf = 1.0, other labeled impurities 99mTc-RH RF = 0.0). For the determination of RCP of 99mTc-HDP, Whatman 31ET and acetone was used (99mTc-HDP Rf = 0.0, 99mTcO4- Rf = 1.0, other labeled impurities RF = 0.0). After the development of the solvent front, the strips were allowed to dry and then imaged on the gamma camera (256x256 matrix; zoom 2; LEHR parallel-hole collimator; 5-minute image) and on the radiochromatogram scanner. Then, strips were cut in Rf 0.8 in the case of 99mTc-tetrofosmin and Rf 0.5 in the case of 99mTc-HDP. The resultant pieces were smashed in an assay tube (to minimize the effect of counting geometry) and counted in the dose calibrator and in the well scintillation counter (during 1 minute). The RCP was calculated using the formula: % 99mTc-Complex = [(99mTc-Complex) / (Total amount of 99mTc-labeled species)] x 100. Statistical analysis was done using the test of hypotheses for the difference between means in independent samples. Results:The gamma camera based method demonstrated higher operator-dependency (especially concerning the drawing of the ROIs) and the measures obtained using the dose calibrator are very sensitive to the amount of activity spotted in the chromatographic strip, so the use of a minimum of 3.7 MBq activity is essential to minimize quantification errors. Radiochromatographic scanner and well scintillation counter showed concordant results and demonstrated the higher level of precision. Conclusions: Radiochromatographic scanners and well scintillation counters based methods demonstrate to be the most accurate and less operator-dependant methods.
Resumo:
Na presente dissertação é proposto o desenvolvimento de um novo sistema de calibração de roscados de exteriores através de visão computacional. A calibração de roscados de exterior consiste na obtenção do diâmetro efectivo, do diâmetro exterior e do passo, e no cálculo da incerteza expandida correspondente. Actualmente, a calibração é efectuada com o auxílio de máquinas universais (SIP), na qual o diâmetro efectivo é obtido através de um modelo matemático, pois não se consegue obtê-lo directamente. O sistema de calibração por visão computacional tem como objectivo obter-se o diâmetro efectivo directamente, assim como as restantes características. A vantagem deste novo sistema será para roscados com dimensões inferiores a 2 mm, que não se conseguem medir utilizando a SIP. A desvantagem é referente a diâmetros superiores a 2 mm, devido à resolução obtida com a câmara utilizada. Este sistema foi validado por comparação com a calibração utilizando como equipamento calibrador a SIP. Ao longo da dissertação irão ser explicados todos os passos dados para a calibração de roscados de exterior.