7 resultados para pedra-ume-caá
em Instituto Politécnico do Porto, Portugal
Resumo:
Mestrado em Engenharia Geotécnica e Geoambiente
Flavoured versus natural waters: macromineral (Ca, Mg, K, Na) and micromineral (Fe, Cu, Zn) contents
Resumo:
Macro (Ca, Mg, K, Na) and micromineral (Fe, Zn, Cu) composition of 39 waters was analysed. Determinations were made by atomic flame spectrophotometry for macrominerals and electrothermic atomisation in graphite furnace for microminerals. Mineral contents of still or sparkling natural waters (without flavours) changed from brand to brand. Mann–Whitney test was used to search for significant differences between flavoured and natural waters. For that, the concentration of each mineral was compared to the presence of flavours, preservatives, acidifying agents, fruit juice and/or sweeteners, according to the labelled composition. The statistical study demonstrated that flavoured waters generally have increased contents of K, Na, Fe and Cu. The added preservatives also led to significant differences in the mineral composition. Acidifying agents and fruit juice can also be correlated to the increase of Mg, K, Na, Fe and Cu. Sweeteners do not provide any significant difference in Ca, Mg, Fe and Zn contents.
Improving the IEEE 802.15.4 Slotted CSMA/CA MAC for time-critical events in wireless sensor networks
Resumo:
In beacon-enabled mode, IEEE 802.15.4 is ruled by the slotted CSMA/CA Medium Access Control (MAC) protocol. The standard slotted CSMA/CA mechanism does not provide any means of differentiated services to improve the quality of service for timecritical events (such as alarms, time slot reservation, PAN management messages etc.). In this paper, we present and discuss practical service differentiation mechanisms to improve the performance of slotted CSMA/CA for time-critical events, with only minor add-ons to the protocol. The contribution of our proposal is more practical than theoretical since our initial requirement is to leave the original algorithm of the slotted CSMA/CA unchanged, but rather tuning its parameters adequately according to the criticality of the messages. We present a simulation study based on an accurate model of the IEEE 802.15.4 MAC protocol, to evaluate the differentiated service strategies. Four scenarios with different settings of the slotted CSMA/CA parameters are defined. Each scenario is evaluated for FIFO and Priority Queuing. The impact of the hiddennode problem is also analyzed, and a solution to mitigate it is proposed.
Resumo:
In this paper, we analyze the performance limits of the slotted CSMA/CA mechanism of IEEE 802.15.4 in the beacon-enabled mode for broadcast transmissions in WSNs. The motivation for evaluating the beacon-enabled mode is due to its flexibility for WSN applications as compared to the non-beacon enabled mode. Our analysis is based on an accurate simulation model of the slotted CSMA/CA mechanism on top of a realistic physical layer, with respect to the IEEE 802.15.4 standard specification. The performance of the slotted CSMA/CA is evaluated and analyzed for different network settings to understand the impact of the protocol attributes (superframe order, beacon order and backoff exponent) on the network performance, namely in terms of throughput (S), average delay (D) and probability of success (Ps). We introduce the concept of utility (U) as a combination of two or more metrics, to determine the best offered load range for an optimal behavior of the network. We show that the optimal network performance using slotted CSMA/CA occurs in the range of 35% to 60% with respect to an utility function proportional to the network throughput (S) divided by the average delay (D).
Resumo:
The IEEE 802.15.4 has been adopted as a communication protocol standard for Low-Rate Wireless Private Area Networks (LRWPANs). While it appears as a promising candidate solution for Wireless Sensor Networks (WSNs), its adequacy must be carefully evaluated. In this paper, we analyze the performance limits of the slotted CSMA/CA medium access control (MAC) mechanism in the beacon-enabled mode for broadcast transmissions in WSNs. The motivation for evaluating the beacon-enabled mode is due to its flexibility and potential for WSN applications as compared to the non-beacon enabled mode. Our analysis is based on an accurate simulation model of the slotted CSMA/CA mechanism on top of a realistic physical layer, with respect to the IEEE 802.15.4 standard specification. The performance of the slotted CSMA/CA is evaluated and analyzed for different network settings to understand the impact of the protocol attributes (superframe order, beacon order and backoff exponent), the number of nodes and the data frame size on the network performance, namely in terms of throughput (S), average delay (D) and probability of success (Ps). We also analytically evaluate the impact of the slotted CSMA/CA overheads on the saturation throughput. We introduce the concept of utility (U) as a combination of two or more metrics, to determine the best offered load range for an optimal behavior of the network. We show that the optimal network performance using slotted CSMA/CA occurs in the range of 35% to 60% with respect to an utility function proportional to the network throughput (S) divided by the average delay (D).
Resumo:
O ingresso no mercado de trabalho e primeiro contacto com a realidade na construção em Portugal motivaram a realização deste relatório. O qual tem como base o estágio realizado na Sika® Portugal Produtos da Construção e Indústria, S.A. como elemento do Departamento Técnico. O trabalho desenvolvido incide sobre a escolha de soluções de reabilitação e na avaliação preliminar do estado de conservação dos edifícios outrora reabilitados com soluções Sika®. A primeira parte deste relatório descreve a adaptação do método de avaliação do estado de conservação de edifícios (MAEC) de forma a realizar esta avaliação apenas no sistema construtivo que compõe a fachada, aplicado num estudo desenvolvido para 100 obras de reabilitação em edifícios distribuídos no território nacional. Numa segunda parte do relatório são apresentados documentos desenvolvidos durante a actividade profissional aquando de visitas às obras e respectivas análises preliminares e especificações técnicas. Nesta segunda parte do relatório mais relacionada com as actividades diárias são ainda apresentados documentos técnicos de apoio a tecnologias e ou selecção de soluções mais adequadas às exigências e necessidades de comportamento dos materiais. É ainda abordado o tema sustentabilidade que actualmente é uma das preocupações nas escolhas e tomadas de decisão de soluções para a reabilitação e construção nova. Apresenta-se ainda um estudo realizado em laboratório que visa determinar o comprimento de amarração de fios ou cordões de pré-esforço colados com resina epoxy a provetes de diferentes tipos de pedra natural.
Resumo:
Ao longo das últimas décadas o município de Amarante tem-se deparado com inúmeros problemas de instabilidade de estruturas de suporte de terras, maioritariamente instabilidade de taludes artificiais, (escavação e/ou aterro) e muros de contenção tradicionais em alvenaria de pedra. A unidade técnica de projeto, ou UTP da Câmara Municipal de Amarante tem vindo a elaborar estudos, projetos e adjudicar as obras para repor a normalidade apos a instabilização desses elementos, contudo a frequência de ocorrência destes fenómenos e os recursos necessários para a sua resolução ultrapassam a capacidade desta unidade, levando a que muitos destes casos se arrastem durante anos antes de ser reposta a sua normalidade. Perante este panorama revelou-se necessário efetuar um estudo de forma a listar, avaliar e priorizar os vários casos de instabilidade existentes, para uma eficiente alocação dos recursos disponíveis. Esta análise pretende ainda identificar as principais causas de instabilidade destas estruturas, de forma a eliminar ou mitigar a ocorrência de futuros problemas semelhantes. Para o estudo destes elementos de contenção de terras adotou-se o método de análise de risco conhecido como FMEA, “Failure Modes and Effects Analysis” ou Analise dos Modos de Falha e Efeitos, com as adaptações necessárias de forma a maximizar a confiabilidade das avaliações mediante a especificidade dos casos a avaliar e realidade da instituição.