9 resultados para peanut hull

em Instituto Politécnico do Porto, Portugal


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Mestrado em Engenharia Química

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The main goal of this research study was the removal of Cu(II), Ni(II) and Zn(II) from aqueous solutions using peanut hulls. This work was mainly focused on the following aspects: chemical characterization of the biosorbent, kinetic studies, study of the pH influence in mono-component systems, equilibrium isotherms and column studies, both in mono and tri-component systems, and with a real industrial effluent from the electroplating industry. The chemical characterization of peanut hulls showed a high cellulose (44.8%) and lignin (36.1%) content, which favours biosorption of metal cations. The kinetic studies performed indicate that most of the sorption occurs in the first 30 min for all systems. In general, a pseudo-second order kinetics was followed, both in mono and tri-component systems. The equilibrium isotherms were better described by Freundlich model in all systems. Peanut hulls showed higher affinity for copper than for nickel and zinc when they are both present. The pH value between 5 and 6 was the most favourable for all systems. The sorbent capacity in column was 0.028 and 0.025 mmol g-1 for copper, respectively in mono and tri-component systems. A decrease of capacity for copper (50%) was observed when dealing with the real effluent. The Yoon-Nelson, Thomas and Yan’s models were fitted to the experimental data, being the latter the best fit.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This research work aims to study the use of peanut hulls, an agricultural and food industry waste, for copper and lead removal through equilibrium and kinetic parameters evaluation. Equilibrium batch studies were performed in a batch adsorber. The influence of initial pH was evaluated (3–5) and it was selected between 4.0 and 4.5. The maximum sorption capacities obtained for the Langmuir model were 0.21 ± 0.03 and 0.18 ± 0.02 mmol/g, respectively for copper and lead. In bi-component systems, competitive sorption of copper and lead was verified, the total amount adsorbed being around 0.21 mmol of metal per gram of material in both mono and bi-component systems. In the kinetic studies equilibrium was reached after 200 min contact time using a 400 rpm stirring rate, achieving 78% and 58% removal, in mono-component system, for copper and lead respectively. Their removal follows a pseudo-second-order kinetics. These studies show that most of the metals removal occurred in the first 20 min of contact, which shows a good uptake rate in all systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A gold nanoparticle-coated screen-printed carbon electrode was used as the transducer in the development of an electrochemical immunosensor for Ara h 1 (a major peanut allergen) detection in food samples. Gold nanoparticles (average diameter=32 nm) were electrochemically generated on the surface of screen-printed carbon electrodes. Two monoclonal antibodies were used in a sandwich-type immunoassay and the antibody–antigen interaction was electrochemically detected through stripping analysis of enzymatically (using alkaline phosphatase) deposited silver. The total time of the optimized immunoassay was 3 h 50 min. The developed immunosensor allowed the quantification of Ara h 1 between 12.6 and 2000 ng/ml, with a limit of detection of 3.8 ng/ml, and provided precise (RSD <8.7%) and accurate (recovery >96.6%) results. The immunosensor was successfully applied to the analysis of complex food matrices (cookies and chocolate), being able to detect Ara h 1 in samples containing 0.1% of peanut.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A voltammetric biosensor for Ara h 6 (a peanut allergen) detection in food samples was developed. Gold nanoparticle-modified screen-printed carbon electrodes were used to develop a sandwich-type immunoassay using two-monoclonal antibodies. The antibody-antigen interaction was detected through the electrochemical detection of enzymatically deposited silver. The immunosensor presented a linear range between 1 and 100 ng/ml, as well as high precision (inter-day RSD ≤9.8 %) and accuracy (recoveries ≥96.7 %). The detection and quantification limits were 0.27 and 0.88 ng/ml, respectively. It was possible to detect small levels of Ara h 6 in complex food matrices.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação de Mestrado Apresentado ao Instituto de Contabilidade e Administração do Porto para a obtenção do grau de Mestre em Contabilidade e Finanças, sob orientação de Mestre José Carlos Pedro

Relevância:

10.00% 10.00%

Publicador:

Resumo:

There is an interest to create zinc/tin alloys to replace cadmium as a corrosion protective coating material. Existing aqueous electroplating systems for these alloys are commercially available but have several limitations. Dangerous and highly toxic complexing agents are uses e.g. cyanides. To overcome these problems, ionic liquids could provide a solution to obtain an alloy containing 20 to 30% of zinc. Ionic liquids (IL’s) often have wider electrochemical windows which allow the deposition of e.g. refractive metals that can not be deposited from aqueous solutions. In IL’s it is often not necessary to add complexing agents. The Zn/Sn alloy deposition from IL’s is therefore a promising application for the plating industry. Nevertheless, there are some issues with this alternative for aqueous systems. The degradation of the organic components, the control of the concentration of two metals and the risk of a two phase deposition instead of an alloy had to be overcome first. It is the main purpose of this thesis to obtain a Zn/Sn alloy with 20% zinc using IL’s as an electrolyte. First a separate study was performed on both the zinc and the tin deposition. Afterwards, an attempt to deposit a Zn/Sn alloy was made. An introduction to a study about the electrodeposition of refractive metals concludes this work. It initiated the research for oxygen-free IL’s to deposit molybdenum or tungsten. Several parameters (temperature, metal source and concentration, organic complexing agents,…) were optimized for both the zinc, tin and zinc/tin deposition. Experiments were performed both in a parallel plate cell and a Hull cell, so as to investigate the effect of current density as well. Ethaline200 was selected as electrolyte. As substrate, brass and iron were selected, while as anode a plate of the metal to deposit was chosen, tin for the alloy. The best efficiencies were always obtained on brass; however the iron substrate resulted in the best depositions. A concentration of 0.27M ZnCl2, 0.07M SnCl2 with 0.015M of K3-HEDTA as complexant resulted in a deposition containing the desired alloy with the amount of 20% zinc and 80% tin with good appearance. Refractory metals as molybdenum and tungsten cannot be electrodeposited from aqueous solutions without forming a co-deposition with Ni, Co or Fe. Here, IL’s could again provide a solution. A first requirement is the dissolution of a metal source. MoO3 could be suitable, however there are doubts about using oxides. Oxygen-free IL’s were sought for. A first attempt was the combination of ZnCl2 with chlormequat (CCC), which gave liquids below 150°C in molar ratios of 2 : 1 and 3 : 1. Unfortuna tely, MoO3 didn’t dissolve in these IL’s. Another route to design oxygen-free IL’s was the synthesis of quaternary ammonium salts. None of the methods used, proved viable as reaction time was long and resulted in very low yields. Therefore, no sufficient quantities were obtained to perform the possible electrochemical behavior of refractive metals.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nos dias de hoje é necessário criar hábitos de vida mais saudáveis que contribuam para o bem-estar da população. Adoptar medidas e práticas de modo regular e disciplinado, pode diminuir o risco do aparecimento de determinadas doenças, como a obesidade, as doenças cardiovasculares, a hipertensão, a diabetes, alguns tipos de cancro e tantas outras. É também importante salientar que, uma alimentação cuidada dá saúde e aumenta a esperança média de vida. Em Portugal, nos últimos anos, os costumes alimentares da população têm vindo a alterar-se significativamente. As refeições caseiras confeccionadas com produtos frescos dão lugar à designada “cultura do fast food”. Em contrapartida, os consumidores são cada vez mais exigentes, estando em permanente alerta no que se refere ao estado dos alimentos. A rotulagem de um produto, para além da função publicitária, tem vindo a ser objecto de legislação específica de forma a fornecer informação simples e clara, correspondente à composição, qualidade, quantidade, validade ou outras características do produto. Estas informações devem ser acessíveis a qualquer tipo de público, com mais ou menos formação e de qualquer estrato social. A qualidade e segurança dos produtos deve basear-se na garantia de que todos os ingredientes, materiais de embalagem e processos produtivos são adequados à produção de produtos seguros, saudáveis e saborosos. A Silliker Portugal, S.A. é uma empresa independente de prestação de serviços para o sector agro-alimentar, líder mundial na prestação de serviços para a melhoria da qualidade e segurança alimentar. A Silliker dedica-se a ajudar as empresas a encontrar soluções para os desafios actuais do sector, oferecendo uma ampla gama de serviços, onde se inclui o serviço de análises microbiológicas, químicas e sensorial; consultadoria em segurança alimentar e desenvolvimento; auditorias; rotulagem e legislação. A actualização permanente de procedimentos na procura de uma melhoria contínua é um dos objectivos da empresa. Para responder a um dos desafios colocados à Silliker, surgiu este trabalho, que consistiu no desenvolvimento de um novo método para determinação de ácidos gordos e da gordura total em diferentes tipos de alimentos e comparação dos resultados, com os obtidos com o método analítico até então adoptado. Se a gordura é um elemento de grande importância na alimentação, devido às suas propriedades nutricionais e organoléticas, recentemente, os investigadores têm focado a sua atenção nos mais diversos ácidos gordos (saturados, monoinsaturados e polinsaturados), em particular nos ácidos gordos essenciais e nos isómeros do ácido linoleico conjugado (CLA), uma mistura de isómeros posicionais e geométricos do ácido linoleico com actividade biológica importante. A técnica usada nas determinações foi a cromatografia gasosa com ionização de chama, GC-FID, tendo as amostras sido previamente tratadas e extraídas de acordo com o tipo de matriz. A metodologia analítica desenvolvida permitiu a correcta avaliação do perfil em ácidos gordos, tendo-se para isso usado uma mistura de 37 ésteres metílicos, em que o ácido gordo C13:0 foi usado como padrão interno. A identificação baseou-se nos tempos de retenção de cada ácido gordo da mistura e para a quantificação usaram-se os factores de resposta. A validação do método implementado foi baseada nos resultados obtidos no estudo de três matrizes relativas a materiais certificados pela BIPEA (Bureau Interprofessionnel des Etudes Analytiques), para o que foram efectuadas doze réplicas de cada matriz. Para cada réplica efectuada foi calculado o teor de matéria gorda, sendo posteriormente o resultado comparado com o emitido pela entidade certificada. Após análise de cada constituinte foi também possível calcular o teor em ácidos gordos saturados, monoinsaturados e polinsaturados. A determinação do perfil em ácidos gordos dos materiais certificados foi aceitável atendendo aos valores obtidos, os quais se encontravam no intervalo de valores admissíveis indicados nos relatórios. A quantificação da matéria gorda no que se refere à matriz de “Paté à Tartinier” apresentou um z-score de 4,3, o que de acordo com as exigências internas da Silliker, não é válido. Para as outras duas matrizes (“Mélange Nutritif” e “Plat cuisiné à base de viande”) os valores de z-score foram, respectivamente, 0,7 e -1,0, o que permite concluir a validade do método. Para que o método possa vir a ser adoptado como método alternativo é necessário um estudo mais alargado relativamente a amostras com diferentes composições. O método foi aplicado na análise de amostras de fiambre, leite gordo, queijo, ovo com ómega 3, amendoim e óleo de girassol, e os resultados foram comparados com os obtidos pelo método até então adoptado.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents the design of low cost, small autonomous surface vehicle for missions in the coastal waters and specifically for the challenging surf zone. The main objective of the vehicle design described in this paper is to address both the capability of operation at sea in relative challenging conditions and maintain a very low set of operational requirements (ease of deployment). This vehicle provides a first step towards being able to perform general purpose missions (such as data gathering or patrolling) and to at least in a relatively short distances to be able to be used in rescue operations (with very low handling requirements) such as carrying support to humans on the water. The USV is based on a commercially available fiber glass hull, it uses a directional waterjet powered by an electrical brushless motor for propulsion, thus without any protruding propeller reducing danger in rescue operations. Its small dimensions (1.5 m length) and weight allow versatility and ease of deployment. The vehicle design is described in this paper both from a hardware and software point of view. A characterization of the vehicle in terms of energy consumption and performance is provided both from test tank and operational scenario tests. An example application in search and rescue is also presented and discussed with the integration of this vehicle in the European ICARUS (7th framework) research project addressing the development and integration of robotic tools for large scale search and rescue operations.