22 resultados para optical waveguide components

em Instituto Politécnico do Porto, Portugal


Relevância:

40.00% 40.00%

Publicador:

Resumo:

The total antioxidant capacity (TAC) of 28 flavoured water samples was assessed by ferric reducing antioxidant potential (FRAP), oxygen radical absorbance capacity (ORAC), trolox equivalent antioxidant capacity (TEAC) and total reactive antioxidant potential (TRAP) methods. It was observed that flavoured waters had higher antioxidant activity than the corresponding natural ones. The observed differences were attributed to flavours, juice and vitamins. Generally, higher TAC contents were obtained on lemon waters and lower values on guava and raspberry flavoured waters. Lower and higher TACs were obtained by TRAP and ORAC method, respectively. Statistical analysis suggested that vitamins and flavours increased the antioxidant content of the commercial waters.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Adhesive bonding is nowadays a serious candidate to replace methods such as fastening or riveting, because of attractive mechanical properties. As a result, adhesives are being increasingly used in industries such as the automotive, aerospace and construction. Thus, it is highly important to predict the strength of bonded joints to assess the feasibility of joining during the fabrication process of components (e.g. due to complex geometries) or for repairing purposes. This work studies the tensile behaviour of adhesive joints between aluminium adherends considering different values of adherend thickness (h) and the double-cantilever beam (DCB) test. The experimental work consists of the definition of the tensile fracture toughness (GIC) for the different joint configurations. A conventional fracture characterization method was used, together with a J-integral approach, that take into account the plasticity effects occurring in the adhesive layer. An optical measurement method is used for the evaluation of crack tip opening and adherends rotation at the crack tip during the test, supported by a Matlab® sub-routine for the automated extraction of these quantities. As output of this work, a comparative evaluation between bonded systems with different values of adherend thickness is carried out and complete fracture data is provided in tension for the subsequent strength prediction of joints with identical conditions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Optical immersion clearing is a technique that has been widely studied for more than two decades and that is used to originate a temporary transparency effect in biological tissues. If applied in cooperation with clinical methods it provides optimization of diagnosis and treatment procedures. This technique turns biological tissues more transparent through two main mechanisms — tissue dehydration and refractive index (RI) matching between tissue components. Such matching is obtained by partial replacement of interstitial water by a biocompatible agent that presents higher RI and it can be completely reversible by natural rehydration in vivo or by assisted rehydration in ex vivo tissues. Experimental data to characterize and discriminate between the two mechanisms and to find new ones are necessary. Using a simple method, based on collimated transmittance and thickness measurements made from muscle samples under treatment, we have estimated the diffusion properties of glucose, ethylene glycol (EG) and water that were used to perform such characterization and discrimination. Comparing these properties with data from literature that characterize their diffusion in water we have observed that muscle cell membrane permeability limits agent and water diffusion in the muscle. The same experimental data has allowed to calculate the optical clearing (OC) efficiency and make an interpretation of the internal changes that occurred in muscle during the treatments. The same methodology can now be used to perform similar studies with other agents and in other tissues in order to solve engineering problems at design of inexpensive and robust technologies for a considerable improvement of optical tomographic techniques with better contrast and in-depth imaging.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report within this paper the development of a fiber-optic based sensor for Hg(II) ions. Fluorescent carbon nanoparticles were synthesized by laser ablation and functionalized with PEG200 and N-acetyl-l-cysteine so they can be anionic in nature. This characteristic facilitated their deposition by the layer-by-layer assembly method into thin alternating films along with a cationic polyelectrolyte, poly(ethyleneimine). Such films could be immobilized onto the tip of a glass optical fiber, allowing the construction of an optical fluorescence sensor. When immobilized on the fiber-optic tip, the resultant sensor was capable of selectively detecting sub-micromolar concentrations of Hg(II) with an increased sensitivity compared to carbon dot solutions. The fluorescence of the carbon dots was quenched by up to 44% by Hg(II) ions and interference from other metal ions was minimal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A esquizofrenia é uma perturbação mental grave caracterizada pela coexistência de sintomas positivos, negativos e de desorganização do pensamento e do comportamento. As alterações motoras são consistentemente observadas mas, ainda pouco estudadas na esquizofrenia, sendo relevantes para o seu diagnóstico. Neste quadro, o presente estudo tem como objetivo verificar se os indivíduos com esquizofrenia apresentam alterações na coordenação motora, comparativamente com o grupo sem esquizofrenia, bem como analisar se as disfunções dos sinais neurológicos subtis (SNS) motores se encontram correlacionadas com o funcionamento executivo e com os domínios psicopatológicos da perturbação. No total participaram 29 indivíduos (13 com diagnóstico de esquizofrenia e 16 sem diagnóstico) equivalentes em termos de idade, género, escolaridade e índice de massa corporal. Para avaliar o desempenho motor recorreu-se ao sistema Biostage de parametrização do movimento em tempo real, com a tarefa de lançameto ao alvo; a presença de SNS foi examinada através da Brief Motor Scale; o funcionamento executivo pela aplicação do subteste do Vocabulário e da fluência verbal e a sintomatologia clínica através da Positive and Negative Sindrome Scale. Pela análise cinemática do movimento constatou-se que os indivíduos com esquizofrenia recrutam um padrão motor menos desenvolvido e imaturo de movimento, com menor individualização das componentes (principalmente do tronco e pélvis), necessitando de mais tempo para executar a tarefa, comparativamente com os sujeitos sem a perturbação que evidenciaram um movimento mais avançado de movimento. Os indivíduos com esquizofrenia mostraram índices elevados de disfunção dos SNS (média =6,01) estabelecendo este domínio uma relação boa e negativa com o desempenho verbal (rho Spearman=-0,62) e uma relação forte e positiva com todos os domínios psicopatológicos (rho Spearman=0,74). O estudo da existência de alterações motoras como parte intrínseca da esquizofrenia revela-se pertinente uma vez que possibilita uma compreensão mais aprofundada da sua fisiopatologia e permite que se desenvolvam práticas mais efetivas na área da saúde e reabilitação.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The antioxidant profiles of 39 water samples (29 flavored waters based on 10 natural waters) and 6 flavors used in their formulation (furnished by producers) were determined. Total phenol and flavonoid contents, reducing power, and DPPH radical scavenging activity were the optical techniques implemented and included in the referred profile. Flavor extracts were analyzed by HS-SPME/GC-MS to obtain the qualitative and quantitative profiles of the volatile fraction of essential oils. Results pointed out a higher reducing power (0.14 11.8 mg of gallic acid/L) and radical scavenging activity (0.29 211.5 mg Trolox/L) of flavored waters compared with the corresponding natural ones, an interesting fact concerning human health. Bioactive compounds, such as polyphenols, were present in all samples (0.5 359 mg of gallic acid/L), whereas flavonoids were not present either in flavored waters or in flavors. The major components of flavor extracts were monoterpenes, such as citral, R-limonene, carveol, and R-terpineol.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An optical fiber sensor for Hg(II) in aqueous solution based on sol–gel immobilized carbon dots nanoparticles functionalized with PEG200 and N-acetyl-l-cysteine is described. This sol–gel method generated a thin (about 750 nm), homogenous and smooth (roughness of 2.7±0.7 a˚ ) filmthat immobilizes the carbon dots and allows reversible sensing of Hg(II) in aqueous solution. A fast (less than 10 s), reversible and stable (the fluorescence intensity measurements oscillate less than 1% after several calibration cycles) sensor system was obtained. The sensor allow the detection of submicron molar concentrations of Hg(II) in aqueous solution. The fluorescence intensity of the immobilized carbon dots is quenched by the presence of Hg(II) with a Stern-Volmer constant (pH = 6.8) of 5.3×105M−1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cu2ZnSnS4 is a promising semiconductor to be used as absorber in thin film solar cells. In this work, we investigated optical and structural properties of Cu2ZnSnS4 thin films grown by sulphurization of metallic precursors deposited on soda lime glass substrates. The crystalline phases were studied by X-ray diffraction measurements showing the presence of only the Cu2ZnSnS4 phase. The studied films were copper poor and zinc rich as shown by inductively coupled plasma mass spectroscopy. Scanning electron microscopy revealed a good crystallinity and compactness. An absorption coefficient varying between 3 and 4×104cm−1 was measured in the energy range between 1.75 and 3.5 eV. The band gap energy was estimated in 1.51 eV. Photoluminescence spectroscopy showed an asymmetric broad band emission. The dependence of this emission on the excitation power and temperature was investigated and compared to the predictions of the donor-acceptor-type transitions and radiative recombinations in the model of potential fluctuations. Experimental evidence was found to ascribe the observed emission to radiative transitions involving tail states created by potential fluctuations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the current context of serious climate changes, where the increase of the frequency of some extreme events occurrence can enhance the rate of periods prone to high intensity forest fires, the National Forest Authority often implements, in several Portuguese forest areas, a regular set of measures in order to control the amount of fuel mass availability (PNDFCI, 2008). In the present work we’ll present a preliminary analysis concerning the assessment of the consequences given by the implementation of prescribed fire measures to control the amount of fuel mass in soil recovery, in particular in terms of its water retention capacity, its organic matter content, pH and content of iron. This work is included in a larger study (Meira-Castro, 2009(a); Meira-Castro, 2009(b)). According to the established praxis on the data collection, embodied in multidimensional matrices of n columns (variables in analysis) by p lines (sampled areas at different depths), and also considering the quantitative data nature present in this study, we’ve chosen a methodological approach that considers the multivariate statistical analysis, in particular, the Principal Component Analysis (PCA ) (Góis, 2004). The experiments were carried out in a soil cover over a natural site of Andaluzitic schist, in Gramelas, Caminha, NW Portugal, who was able to maintain itself intact from prescribed burnings from four years and was submit to prescribed fire in March 2008. The soils samples were collected from five different plots at six different time periods. The methodological option that was adopted have allowed us to identify the most relevant relational structures inside the n variables, the p samples and in two sets at the same time (Garcia-Pereira, 1990). Consequently, and in addition to the traditional outputs produced from the PCA, we have analyzed the influence of both sampling depths and geomorphological environments in the behavior of all variables involved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Auditory event-related potentials (AERPs) are widely used in diverse fields of today’s neuroscience, concerning auditory processing, speech perception, language acquisition, neurodevelopment, attention and cognition in normal aging, gender, developmental, neurologic and psychiatric disorders. However, its transposition to clinical practice has remained minimal. Mainly due to scarce literature on normative data across age, wide spectrumof results, variety of auditory stimuli used and to different neuropsychological meanings of AERPs components between authors. One of the most prominent AERP components studied in last decades was N1, which reflects auditory detection and discrimination. Subsequently, N2 indicates attention allocation and phonological analysis. The simultaneous analysis of N1 and N2 elicited by feasible novelty experimental paradigms, such as auditory oddball, seems an objective method to assess central auditory processing. The aim of this systematic review was to bring forward normative values for auditory oddball N1 and N2 components across age. EBSCO, PubMed, Web of Knowledge and Google Scholarwere systematically searched for studies that elicited N1 and/or N2 by auditory oddball paradigm. A total of 2,764 papers were initially identified in the database, of which 19 resulted from hand search and additional references, between 1988 and 2013, last 25 years. A final total of 68 studiesmet the eligibility criteria with a total of 2,406 participants from control groups for N1 (age range 6.6–85 years; mean 34.42) and 1,507 for N2 (age range 9–85 years; mean 36.13). Polynomial regression analysis revealed thatN1latency decreases with aging at Fz and Cz,N1 amplitude at Cz decreases from childhood to adolescence and stabilizes after 30–40 years and at Fz the decrement finishes by 60 years and highly increases after this age. Regarding N2, latency did not covary with age but amplitude showed a significant decrement for both Cz and Fz. Results suggested reliable normative values for Cz and Fz electrode locations; however, changes in brain development and components topography over age should be considered in clinical practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Com um mercado automóvel cada vez mais competitivo e com os construtores automóveis à procura de atingir os zero defeitos nos seus produtos, a Bosch Car Multimédia Portugal S.A, fabricante de sistemas multimédia para o mercado automóvel, tem como objetivo a qualidade perfeita dos seus produtos. Tal perfeição exige processos de fabrico cada vez mais evoluídos e com melhores sistemas de auxílio à montagem. Nesse sentido, a incorporação de sistemas de visão artificial para verificação da montagem correta dos componentes em sistemas multimédia tem vindo a crescer largamente. Os sistemas de inspeção visual da Cognex tornaram-se o standard da Bosch para a verifi-cação da montagem de componentes por serem sistemas bastante completos, fáceis de con-figurar e com um suporte técnico bastante completo. Estes sistemas têm vindo a ser inte-grados em diversas máquinas (postos) de montagem e nunca foi desenvolvida uma ferra-menta normalizada para integração destes sistemas com as máquinas. A ideia principal deste projeto passou por desenvolver um sistema (uma aplicação informá-tica) que permita controlar os indicadores de qualidade destes sistemas de visão, garantir o seguimento dos produtos montados e, ao mesmo tempo, efetuar cópias de segurança de todo o sistema para utilização em caso de avaria ou de troca de equipamento. Tal sistema foi desenvolvido recorrendo à programação de uma Dynamic Link Library (DLL), através da linguagem VisualBasic.NET, que permite às aplicações dos equipamen-tos (máquinas) da Bosch Car Multimédia comunicarem de uma forma universal e transpa-rente com os sistemas de inspeção visual da marca Cognex. Os objetivos a que o autor se propôs no desenvolvimento deste sistema foram na sua maioria alcançados e o projeto encontra-se atualmente implementado e em execução nas linhas de produção da Bosch Car Multimédia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Advanced glycation end-products are Maillard reaction products that are found in thermal processed food. This compounds are often referred as unhealthy for human diet, namely because of their capacity to form amino-acid dimers. There is a broad range of answers to get about how these products are formed, how they interact with the organism and how these reactions can be inhibited to prevent the referred effects. Some compounds from garlic are thought to be able to inhibit these reactions. This study using spectrophotometric, High Performance Liquid Chromatography-Tandem Mass Spectrometry (HPLC-MS/MS) and Fourier transformed infrared spectroscopy (FTIR) analysis, helps to understand better not only not only the effect of some compounds obtained from garlic, diallyl sulfide (DAS), diallyl disulfide (DADS) and diallyl trisulfide (DATS), on these AGEs production reaction, but also helped to understand better the reaction itself.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel optical disposable probe for screening fluoroquinolones in fish farming waters is presented, having Norfloxacin (NFX) as target compound. The colorimetric reaction takes place in the solid/liquid interface consisting of a plasticized PVC layer carrying the colorimetric reagent and the sample solution. NFX solutions dropped on top of this solid-sensory surface provided a colour change from light yellow to dark orange. Several metals were tested as colorimetric reagents and Fe(III) was selected. The main parameters affecting the obtained colour were assessed and optimised in both liquid and solid phases. The corresponding studies were conducted by visible spectrophotometry and digital image acquisition. The three coordinates of the HSL model system of the collected image (Hue, Saturation and Lightness) were obtained by simple image management (enabled in any computer). The analytical response of the optimised solid-state optical probe against concentration was tested for several mathematical transformations of the colour coordinates. Linear behaviour was observed for logarithm NFX concentration against Hue+Lightness. Under this condition, the sensor exhibited a limit of detection below 50 μM (corresponding to about 16 mg/mL). Visual inspection also enabled semi-quantitative information. The selectivity was ensured against drugs from other chemical groups than fluoroquinolones. Finally, similar procedure was used to prepare an array of sensors for NFX, consisting on different metal species. Cu(II), Mn(II) and aluminon were selected for this purpose. The sensor array was used to detect NFX in aquaculture water, without any prior sample manipulation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cyanobacteria deteriorate the water quality and are responsible for emerging outbreaks and epidemics causing harmful diseases in Humans and animals because of their toxins. Microcystin-LR (MCT) is one of the most relevant cyanotoxin, being the most widely studied hepatotoxin. For safety purposes, the World Health Organization recommends a maximum value of 1 μg L−1 of MCT in drinking water. Therefore, there is a great demand for remote and real-time sensing techniques to detect and quantify MCT. In this work a Fabry–Pérot sensing probe based on an optical fibre tip coated with a MCT selective thin film is presented. The membranes were developed by imprinting MCT in a sol–gel matrix that was applied over the tip of the fibre by dip coating. The imprinting effect was obtained by curing the sol–gel membrane, prepared with (3-aminopropyl) trimethoxysilane (APTMS), diphenyl-dimethoxysilane (DPDMS), tetraethoxysilane (TEOS), in the presence of MCT. The imprinting effect was tested by preparing a similar membrane without template. In general, the fibre Fabry–Pérot with a Molecular Imprinted Polymer (MIP) sensor showed low thermal effect, thus avoiding the need of temperature control in field applications. It presented a linear response to MCT concentration within 0.3–1.4 μg L−1 with a sensitivity of −12.4 ± 0.7 nm L μg−1. The corresponding Non-Imprinted Polymer (NIP) displayed linear behaviour for the same MCT concentration range, but with much less sensitivity, of −5.9 ± 0.2 nm L μg−1. The method shows excellent selectivity for MCT against other species co-existing with the analyte in environmental waters. It was successfully applied to the determination of MCT in contaminated samples. The main advantages of the proposed optical sensor include high sensitivity and specificity, low-cost, robustness, easy preparation and preservation.