18 resultados para optical spectrum analyzer
em Instituto Politécnico do Porto, Portugal
Resumo:
During the past 15 years, emergence and dissemination of third-generation cephalosporins resistance in nosocomial Enterobacteriaceae became a serious problem worldwide, due to the production of extended-spectrum-β-lactamases (ESBLs). The aim of this study was to investigate among the presence of ESBL-producing enterobacteria among Portuguese clinical isolates nearby Spain, to investigate the antimicrobial susceptibility patterns and to compare the two countries. The β-lactamases genes, blaTEM, blaSHV and blaCTX-M were detected by molecular methods. Among the ESBL-producing isolates it was found extraordinary levels (98.9%) of resistance to the fourth-generation cephalosporin Cefepime. These findings point to the need of reevaluate the definition of ESBL.
Resumo:
We report within this paper the development of a fiber-optic based sensor for Hg(II) ions. Fluorescent carbon nanoparticles were synthesized by laser ablation and functionalized with PEG200 and N-acetyl-l-cysteine so they can be anionic in nature. This characteristic facilitated their deposition by the layer-by-layer assembly method into thin alternating films along with a cationic polyelectrolyte, poly(ethyleneimine). Such films could be immobilized onto the tip of a glass optical fiber, allowing the construction of an optical fluorescence sensor. When immobilized on the fiber-optic tip, the resultant sensor was capable of selectively detecting sub-micromolar concentrations of Hg(II) with an increased sensitivity compared to carbon dot solutions. The fluorescence of the carbon dots was quenched by up to 44% by Hg(II) ions and interference from other metal ions was minimal.
Resumo:
An optical fiber sensor for Hg(II) in aqueous solution based on sol–gel immobilized carbon dots nanoparticles functionalized with PEG200 and N-acetyl-l-cysteine is described. This sol–gel method generated a thin (about 750 nm), homogenous and smooth (roughness of 2.7±0.7 a˚ ) filmthat immobilizes the carbon dots and allows reversible sensing of Hg(II) in aqueous solution. A fast (less than 10 s), reversible and stable (the fluorescence intensity measurements oscillate less than 1% after several calibration cycles) sensor system was obtained. The sensor allow the detection of submicron molar concentrations of Hg(II) in aqueous solution. The fluorescence intensity of the immobilized carbon dots is quenched by the presence of Hg(II) with a Stern-Volmer constant (pH = 6.8) of 5.3×105M−1.
Resumo:
Cu2ZnSnS4 is a promising semiconductor to be used as absorber in thin film solar cells. In this work, we investigated optical and structural properties of Cu2ZnSnS4 thin films grown by sulphurization of metallic precursors deposited on soda lime glass substrates. The crystalline phases were studied by X-ray diffraction measurements showing the presence of only the Cu2ZnSnS4 phase. The studied films were copper poor and zinc rich as shown by inductively coupled plasma mass spectroscopy. Scanning electron microscopy revealed a good crystallinity and compactness. An absorption coefficient varying between 3 and 4×104cm−1 was measured in the energy range between 1.75 and 3.5 eV. The band gap energy was estimated in 1.51 eV. Photoluminescence spectroscopy showed an asymmetric broad band emission. The dependence of this emission on the excitation power and temperature was investigated and compared to the predictions of the donor-acceptor-type transitions and radiative recombinations in the model of potential fluctuations. Experimental evidence was found to ascribe the observed emission to radiative transitions involving tail states created by potential fluctuations.
Resumo:
Adhesive bonding is nowadays a serious candidate to replace methods such as fastening or riveting, because of attractive mechanical properties. As a result, adhesives are being increasingly used in industries such as the automotive, aerospace and construction. Thus, it is highly important to predict the strength of bonded joints to assess the feasibility of joining during the fabrication process of components (e.g. due to complex geometries) or for repairing purposes. This work studies the tensile behaviour of adhesive joints between aluminium adherends considering different values of adherend thickness (h) and the double-cantilever beam (DCB) test. The experimental work consists of the definition of the tensile fracture toughness (GIC) for the different joint configurations. A conventional fracture characterization method was used, together with a J-integral approach, that take into account the plasticity effects occurring in the adhesive layer. An optical measurement method is used for the evaluation of crack tip opening and adherends rotation at the crack tip during the test, supported by a Matlab® sub-routine for the automated extraction of these quantities. As output of this work, a comparative evaluation between bonded systems with different values of adherend thickness is carried out and complete fracture data is provided in tension for the subsequent strength prediction of joints with identical conditions.
Resumo:
Tendo por referência a diretiva 2006/95/CE, o trabalho desenvolvido no contexto da disciplina de Dissertação/Projeto/Estágio do Mestrado de Engenharia de Instrumentação e Metrologia, decorreu nas instalações do IEP (Instituto Electrotécnico Português) e teve como objetivo principal o desenvolvimento de um procedimento de avaliação dos efeitos fotobiológicos no olho e pele provocados por fontes de emissão contínua (LED), doravante designado método alternativo ao de referência. Os dois métodos, alternativo e de referência, utilizam respectivamente um foto-radiómetro multicanal e um espetro-radiómetro. O procedimento desenvolvido (método alternativo) de acordo com a norma EN/IEC62471) consiste na aquisição dos valores de irradiância com recurso a um foto-radiómetro e posterior determinação dos valores da radiância, com os quais se faz a avaliação dos efeitos fotobiológicos, para fontes de luz LED (Light Emitting Diode) ou GLS (General Lighting Service). A consulta detalhada da norma EN/IEC62471 e a pesquisa sobre os conceitos, definições, equipamentos e metodologias relacionadas com o tema em causa, constituiu o primeiro passo deste projecto. Com recurso aos dois equipamentos, uma fonte de luz LED (módulo de 12 lâmpadas LED) é avaliada em relação aos perigos (ou riscos) actínico UV e UV-A, ao perigo da luz azul e ainda o perigo térmico na retina e térmico na pele, permitindo fazer uma análise comparativa dos resultados. O método alternativo revelou-se bastante flexível e eficaz, proporcionando bons resultados em termos da irradiância e radiância dos referidos efeitos fotobiológicos. A comparação destes resultados com os valores limites de exposição mencionados na norma EN/IEC6247 permitiu afirmar que a fonte de luz LED avaliada não representa perigo fotobiológico para a saúde humana e classifica-se no grupo de risco “isento”. Uma vez cumpridos os objectivos, entendeu-se que seria uma mais-valia para o trabalho já realizado, estudar outro caso prático. Sendo assim, fez-se a avaliação da radiação de apenas um dos LED´s que constituíam a fonte usada nos ensaios anteriores, com o espetro-radiómetro (método de referência) e com uma distância de 200 mm entre a fonte e o medidor. Neste caso verificaram-se diferenças significativas nas quantidades obtidas quando comparadas com os valores normativos. Concluiu-se que o efeito fotobiológico da luz azul insere-se no grupo de “isento”, sem perigo para a saúde. Contudo, o efeito térmico da retina apresenta um aumento considerável da quantidade de radiância, embora dentro do grupo de risco “isento”. Esta classificação de grupos de risco. Face aos resultados obtidos, pode confirmar-se que as lâmpadas LED apresentam segurança fotobiológica, atendendo aos baixos valores de irradiância e radiância dos efeitos fotobiológicos estudados. Pode ainda afirmar-se que a utilização do foto-radiómetro em alternativa ao espetro-radiómetro se revela mais eficaz do ponto de vista de metodologia prática. Este trabalho demonstra a robustez desses dois equipamentos de avaliação dos efeitos fotobiológicos, e procura estabelecer uma linha de orientação para a prevenção dos efeitos adversos na pele e olhos de todos os seres humanos sujeitos à radiação ótica artificial. Quanto às incertezas de medições, em relação ao processo de medição com foto-radiómetro, a sua estimação não se realizou, devido a não rastreabilidade entre as medições indicadas pelo fabricante, no certificado de calibração e as medidas realizadas por outras entidades. Contudo, é propõe-se a sua realização em trabalhos futuros dentro desse âmbito. As incertezas dos resultados de medições com espetro-radiómetro foram parcialmente estimadas. Atendendo às potencialidades do sistema de medição, propõe-se como trabalho futuro, a aplicação da norma IEC62478, que faz parte da aplicação da norma EN/IEC62471 na avaliação do efeito da luz azul, com base na determinação da temperatura de cor correlacionada (CCT) de lâmpadas ou sistemas de lâmpadas incluindo luminárias. Os valores de irradiância e radiância adquiridos nos processos de avaliação, tanto com foto-radiómetro como espectro-radiómetro foram gravados em ficheiro Excel para um CD e anexados a este trabalho.
Resumo:
The total antioxidant capacity (TAC) of 28 flavoured water samples was assessed by ferric reducing antioxidant potential (FRAP), oxygen radical absorbance capacity (ORAC), trolox equivalent antioxidant capacity (TEAC) and total reactive antioxidant potential (TRAP) methods. It was observed that flavoured waters had higher antioxidant activity than the corresponding natural ones. The observed differences were attributed to flavours, juice and vitamins. Generally, higher TAC contents were obtained on lemon waters and lower values on guava and raspberry flavoured waters. Lower and higher TACs were obtained by TRAP and ORAC method, respectively. Statistical analysis suggested that vitamins and flavours increased the antioxidant content of the commercial waters.
Resumo:
A novel optical disposable probe for screening fluoroquinolones in fish farming waters is presented, having Norfloxacin (NFX) as target compound. The colorimetric reaction takes place in the solid/liquid interface consisting of a plasticized PVC layer carrying the colorimetric reagent and the sample solution. NFX solutions dropped on top of this solid-sensory surface provided a colour change from light yellow to dark orange. Several metals were tested as colorimetric reagents and Fe(III) was selected. The main parameters affecting the obtained colour were assessed and optimised in both liquid and solid phases. The corresponding studies were conducted by visible spectrophotometry and digital image acquisition. The three coordinates of the HSL model system of the collected image (Hue, Saturation and Lightness) were obtained by simple image management (enabled in any computer). The analytical response of the optimised solid-state optical probe against concentration was tested for several mathematical transformations of the colour coordinates. Linear behaviour was observed for logarithm NFX concentration against Hue+Lightness. Under this condition, the sensor exhibited a limit of detection below 50 μM (corresponding to about 16 mg/mL). Visual inspection also enabled semi-quantitative information. The selectivity was ensured against drugs from other chemical groups than fluoroquinolones. Finally, similar procedure was used to prepare an array of sensors for NFX, consisting on different metal species. Cu(II), Mn(II) and aluminon were selected for this purpose. The sensor array was used to detect NFX in aquaculture water, without any prior sample manipulation.
Resumo:
Cyanobacteria deteriorate the water quality and are responsible for emerging outbreaks and epidemics causing harmful diseases in Humans and animals because of their toxins. Microcystin-LR (MCT) is one of the most relevant cyanotoxin, being the most widely studied hepatotoxin. For safety purposes, the World Health Organization recommends a maximum value of 1 μg L−1 of MCT in drinking water. Therefore, there is a great demand for remote and real-time sensing techniques to detect and quantify MCT. In this work a Fabry–Pérot sensing probe based on an optical fibre tip coated with a MCT selective thin film is presented. The membranes were developed by imprinting MCT in a sol–gel matrix that was applied over the tip of the fibre by dip coating. The imprinting effect was obtained by curing the sol–gel membrane, prepared with (3-aminopropyl) trimethoxysilane (APTMS), diphenyl-dimethoxysilane (DPDMS), tetraethoxysilane (TEOS), in the presence of MCT. The imprinting effect was tested by preparing a similar membrane without template. In general, the fibre Fabry–Pérot with a Molecular Imprinted Polymer (MIP) sensor showed low thermal effect, thus avoiding the need of temperature control in field applications. It presented a linear response to MCT concentration within 0.3–1.4 μg L−1 with a sensitivity of −12.4 ± 0.7 nm L μg−1. The corresponding Non-Imprinted Polymer (NIP) displayed linear behaviour for the same MCT concentration range, but with much less sensitivity, of −5.9 ± 0.2 nm L μg−1. The method shows excellent selectivity for MCT against other species co-existing with the analyte in environmental waters. It was successfully applied to the determination of MCT in contaminated samples. The main advantages of the proposed optical sensor include high sensitivity and specificity, low-cost, robustness, easy preparation and preservation.
Resumo:
We are presenting a simple, low-cost and rapid solid-state optical probe for screening chlorpromazine (CPZ) in aquacultures. The method exploits the colourimetric reaction between CPZ and Fe(III) ion that occurs at a solid/liquid interface, the solid layer consisting of ferric iron entrapped in a layer of plasticized PVC. If solutions containing CPZ are dropped onto such a layer, a colour change occurs from light yellow to dark pink or even light blue, depending on the concentration of CPZ. Visual inspection enables the concentration of CPZ to be estimated. The resulting colouration was also monitored by digital image collection for a more accurate quantification. The three coordinates of the hue, saturation and lightness system were obtained by standard image processing along with mathematical data treatment. The parameters affecting colour were assessed and optimized. Studies were conducted by visible spectrophotometry and digital image acquisition, respectively. The response of the optimized probe towards the concentration of CPZ was tested for several mathematical transformations of the colour coordinates, and a linear relation was found for the sum of hue and luminosity. The limit of detection is 50 μM (corresponding to about 16 μg per mL). The probe enables quick screening for CPZ in real water samples with prior sample treatment.
Resumo:
Oceans - San Diego, 2013
Resumo:
Adhesive bonding is an excellent alternative to traditional joining techniques such as welding, mechanical fastening or riveting. However, there are many factors that have to be accounted for during joint design to accurately predict the joint strength. One of these is the adhesive layer thickness (tA). Most of the results are for epoxy structural adhesives, tailored to perform best with small values of tA, and these show that the lap joint strength decreases with increase of tA (the optimum joint strength is usually obtained with tA values between 0.1 and 0.2 mm). Recently, polyurethane adhesives were made available in the market, designed to perform with larger tA values, and whose fracture behaviour is still not studied. In this work, the effect of tA on the tensile fracture toughness (View the MathML source) of a bonded joint is studied, considering a novel high strength and ductile polyurethane adhesive for the automotive industry. This work consists on the fracture characterization of the bond by a conventional and the J-integral techniques, which accurately account for root rotation effects. An optical measurement method is used for the evaluation of crack tip opening (δn) and adherends rotation at the crack tip (θo) during the test, supported by a Matlab® sub-routine for the automated extraction of these parameters. As output of this work, fracture data is provided in traction for the selected adhesive, enabling the subsequent strength prediction of bonded joints.
Resumo:
The use of adhesive joints has increased in recent decades due to its competitive features compared with traditional methods. This work aims to estimate the tensile critical strain energy release rate (GIC) of adhesive joints by the Double-Cantilever Beam (DCB) test. The J-integral is used since it enables obtaining the tensile Cohesive Zone Model (CZM) law. An optical measuring method was developed for assessing the crack tip opening (δn) and adherends rotation (θo). The proposed CZM laws were best approximated by a triangular shape for the brittle adhesive and a trapezoidal shape for the two ductile adhesives.
Resumo:
With the objective to study the variation of optical properties of rat muscle during optical clearing, we have performed a set of optical measurements from that kind of tissue. The measurements performed were total transmittance, collimated transmittance, specular reflectance and total reflectance. This set of measurements is sufficient to determine diffuse reflectance and absorbance of the sample, also necessary to estimate the optical properties. All the performed measurements and calculated quantities will be used later in inverse Monte Carlo (IMC) simulations to determine the evolution of the optical properties of muscle during treatments with ethylene glycol and glucose. The results obtained with the measurements already provide some information about the optical clearing treatments applied to the muscle and translate the mechanisms of turning the tissue more transparent and sequence of regimes of optical clearing.